HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (30 Nov 2024)

GB/T 40185-2021 PDF in English


GB/T 40185-2021 (GB/T40185-2021, GBT 40185-2021, GBT40185-2021)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 40185-2021English155 Add to Cart 0-9 seconds. Auto-delivery. Determination of 5 kinds of ammonium chloride antibacterial agents in toothpaste - High performance liquid chromatography method Valid
Standards related to (historical): GB/T 40185-2021
PDF Preview

GB/T 40185-2021: PDF in English (GBT 40185-2021)

GB/T 40185-2021 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 71.040.40 Y 43 Determination of 5 kinds of ammonium chloride antibacterial agents in toothpaste - High performance liquid chromatography method ISSUED ON: MAY 21, 2021 IMPLEMENTED ON: DECEMBER 01, 2021 Issued by: State Administration for Market Regulation; Standardization Administration of the People's Republic of China. Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Principle ... 4  4 Reagents and standard materials ... 4  5 Instruments ... 5  6 Analysis steps ... 5  7 Expression of analysis results ... 7  8 Precision ... 7  9 Recovery rate ... 7  Annex A (informative) Liquid chromatograms of laura ammonium chloride, benzethonium chloride, cetylpyridinium chloride, mitanium chloride and sitacium chloride standard material ... 8  Determination of 5 kinds of ammonium chloride antibacterial agents in toothpaste - High performance liquid chromatography method 1 Scope This Standard specifies high performance liquid chromatography (HPLC) method for the content of ammonium chloride antibacterial agents - laura ammonium chloride, benzethonium chloride, cetylpyridinium chloride, mitanium chloride and sitacium chloride - in toothpaste. This Standard is applicable to the determination of the content of 5 kinds of ammonium chloride antibacterial agents in toothpaste. The method detection limit of this Standard is: 0.075g/kg (laura ammonium chloride, benzethonium chloride), 0.0125g/kg (cetylpyridinium chloride, methachloride) and 0.025g/kg (sitacium chloride). 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 6682-2008, Water for analytical laboratory use - Specification and test methods 3 Principle The sample is ultrasonically extracted and filtered by water and ethanol. Use high performance liquid chromatography to separate. Use UV to determine. Use external standard method to quantify. 4 Reagents and standard materials Unless otherwise specified, it shall only use the confirmed analytically-pure reagents AND water specified as grade one water in GB/T 6682-2008. 6.3 Determination 6.3.1 Reference conditions of liquid chromatography The reference conditions of liquid chromatography are as follows: a) Chromatographic column: CN column (150×4.6mm, 5μm). b) Mobile phase: Acetonitrile (A) + 0.1% HClO4 aqueous solution (add 1mL of HClO4 into 1L of water) (B). Use isocratic elution: A/B=40:60 (volume ratio). c) Flow rate: 1.0mL/min. d) Injection volume: 10μL. e) Column temperature: 30°C. f) Detection wavelength: 215nm (laura ammonium chloride, mitanium chloride and sitacium chloride), 225nm (benzethonium chloride), 260nm (cetylpyridinium chloride). 6.3.2 Drawing of standard working curve Determine according to liquid chromatography conditions (6.3.1). The linear range of laura ammonium chloride and benzethonium chloride is 0.001 mg/mL~0.2 mg/mL. The linear range of cetylpyridinium chloride and mitanium chloride is 0.0015mg/mL~0.2mg/mL. The linear range of sitacium chloride is 0.003mg/mL~0.2mg/mL. For the liquid chromatograms of 5 mixed standard materials, refer to Figure A.1 ~ Figure A.3 in Annex A. 6.3.3 Quantitative analysis Determine the test sample solution according to the liquid chromatographic conditions (6.3.1). Quantify by comparing the peak area with the standard series. If the response value of the specimen solution exceeds the response value of the standard series, it is necessary to dilute the specimen by an appropriate multiple before injection. 6.3.4 Qualitative confirmation Based on the retention time of the tested component in the standard solution, perform preliminary characterization. During the determination, if the specimen solution has a positive result, it shall be compared with the UV absorption spectrum of the standard product, for qualitative confirmation. 6.4 Blank test Except for not weighing samples, all follow the above steps. ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.