HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (8 Dec 2024)

GB/T 4000-2017 PDF in English


GB/T 4000-2017 (GB/T4000-2017, GBT 4000-2017, GBT4000-2017)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 4000-2017English145 Add to Cart 0-9 seconds. Auto-delivery. Determination of coke reactivity index (CRI) and coke strength after reaction (CSR) Valid
GB/T 4000-2008English140 Add to Cart 0-9 seconds. Auto-delivery. Coke -- Determination of reactivity and strength after reaction Obsolete
GB/T 4000-1996English399 Add to Cart 3 days Coke--Determination of reactivity and strength after reaction Obsolete
GB 4000-1983English279 Add to Cart 3 days Coke--Determination of reactivity and strength after reaction Obsolete
Standards related to (historical): GB/T 4000-2017
PDF Preview

GB/T 4000-2017: PDF in English (GBT 4000-2017)

GB/T 4000-2017 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 75.160.10 H 32 Replacing GB/T 4000-2008 Determination of coke reactivity index (CRI) and coke strength after reaction (CSR) ISSUED ON. OCTOBER 14, 2017 IMPLEMENTED ON. MAY 01, 2018 Issued by. General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of PRC. Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Principles ... 4  4 Test instrument, equipment and materials ... 4  5 Collection and preparation of specimen ... 10  6 Test steps ... 11  7 Calculation of results ... 12  8 Precision ... 13  Appendix A (Informative) Single-point temperature-measuring heating-furnace ... 14  Appendix B (Informative) Purification device of carbon dioxide and nitrogen gas ... 18  Appendix C (Informative) Rapid quantitative drying method for coke’s moisture ... 20  Appendix D (Normative) Test record ... 22  Appendix E (Informative) Calibration method of constant-temperature zone of electric furnace ... 23  References ... 25  Determination of coke reactivity index (CRI) and coke strength after reaction (CSR) 1 Scope This standard specifies the principles of test method, test instruments, equipment and materials, collection and preparation of specimen, test procedures, calculation of results, precision for determination of coke reactivity and coke strength after reaction. This standard is applicable to the determination of the reactivity and strength after reaction of coke which is used in blast furnace ironmaking. The coke for other purposes may refer to this standard 2 Normative references The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this standard. GB/T 1997 Coke-sampling and preparation of specimens YB/T 4494 Technical specifications for mechanical specimen preparation of coke reactivity and coke strength after reaction 3 Principles Weigh a certain amount of coke specimen. Place it in a reactor. After reacting with carbon dioxide at 1100 °C for 2 h, use the percentage of the mass loss of coke to represent the coke reactivity index (abbreviated as CRI). After the post-reaction is subjected to the type-I drum test, use the percentage of the mass of the coke which has a grain size greater than 10 mm to the mass of the coke after reaction to represent the coke strength after reaction (abbreviated as CSR). 4 Test instrument, equipment and materials 4.1 Electric furnace 4.6.2 Nitrogen’s mass-flow controller. the range is 5 L/min, the accuracy is not less than ±1.5% F.S. 4.6.3 The air inlet of the equipment is equipped with the nitrogen pressure- reducing valve. Note. When the gas purity cannot meet the requirements, it may use the instruments in Appendix B for purification and drying. The volume and flow rate of the gas used in this standard are the volume and flow rate in the standard state (0 °C and one barometric pressure). 4.7 Circular-hole sieve φ10 mm, the effective diameter of the sieve frame is 200 mm. φ23 mm, the effective diameter of the sieve frame is 300 mm. φ23 mm and φ25 mm, sieve surface 400 mm x 500 mm, see GB/T 2006 for the production of circular-hole sieve. 4.8 Drying box A blast drying box which has a working chamber’s volume of not less than 0.07 m3. 4.9 Balance The maximum weighing is not more than 1000 g, the sensitivity is 0.1 g. 4.10 Rhodium-platinum thermocouple Type-S, not lower than industrial grade II, installed in a heat-resistant protective tube, to measure and control the temperature of the specimen required for the test conditions. 4.11 Standard specimen A standard specimen of coke reactivity index and coke strength after reaction, which is used to regularly test the stability of the equipment. 4.12 Three-stage heating-furnace method - Testing system of coke reactivity index The schematic diagram is as shown in Figure 5. coke which has large bubble and is in honeycomb status as well as the burner coke which has blackhead and not completely gray. 5.2 Make the coke into approximately spherical particles of 23 mm ~ 25 mm. The mechanical specimen preparation is carried out in accordance with the requirements of YB/T 4494. 5.3 The specimen for the coke of the test coke oven may be directly prepared by the coke which has a grain size greater than 40 mm. 5.4 Use a reducer to reduce the prepared specimen to 900 g, dry it at the temperature of 170 °C ~ 180 °C for 2 h, place it in a drier to cool it to room temperature, then use a sieve of φ23 mm and φ25 mm to remove the coke powder which is adhered to the coke block. Use the quarter method to divide the specimen into four sets, each set is not less than 220 g, contain them into a sealed vessel to prepare for use. The coke’s moisture can be determined by referring to Appendix C. If the coke’s moisture is less than 1%, it may not be dried. 6 Test steps 6.1 Number of tests Perform at least two tests. Record the quantity of coke particles per test, ensure that the difference between the quantity of coke particles used in the repeatability test and the reproducibility test is not more than one. If it cannot guarantee meeting the requirements for the quantity of coke particles, indicate it in the report and state the causes. 6.2 Preparation of specimen Weigh (200 ± 2) g of specimen, accurate to 0.1 g, record the mass as m. The final mass correction may be carried out by replacing a piece of lighter or heavier coke. 6.3 Loading of specimen into reactor Load the coke specimen in the reactor and flatten it, to ensure that the coke layer in the reactor is in the middle of the constant-temperature zone of the electric furnace. Insert the thermocouple into the casing and place it at the center of the material layer. Fix the reactor. Connect the gas inlet of reactor to the gas supply system, to check the gas path to ensure the air-tightness of the system. 6.4 Temperature-rise The electric furnace is heated up, at a heating rate of 8 °C/min ~ 16 °C/min. m - The pre-reaction mass of coke, in grams (g); m1 - The post-reaction mass of coke, in grams (g). 7.2 Coke strength after reaction The coke strength after reaction (CSR) is calculated according to formula (2), the value is expressed in %. Where. m2 - The mass of the coke whose grain size is greater than 10 mm after drumming, the unit is gram (g). The test results of coke reactivity index and coke strength after reaction take the arithmetic mean of the parallel tests, retaining one decimal place. 8 Precision The repeatability and reproducibility of coke reactivity index (CRI) and coke strength after reaction (CSR) shall not exceed the values as specified in Table 1. Repeatability is, using this method under the normal and correct operating conditions, the maximum difference of the two independent test results at the 95% probability level of the two independent tests as made for the same specimens (see 6.2) by the same operator using the same instrument in the same lab in a short time period. Reproducibility is, using this method under the normal and correct operating conditions, the maximum difference of the two independent test results at the 95% probability level of the two independent tests as made for the same specimens (see 6.2) by two operators in the same lab. Table 1 Precision requirements Repeatability / % Reproducibility / % Coke reactivity index (CRI) ≤ 2.4 ≤ 4.0 Coke strength after reaction (CSR) ≤ 3.2 ≤ 5.0 7 - Air inlet; 8 - Thermocouple. Figure A.1 -- Schematic diagram of single-point temperature-measuring heating-furnace structure A.3 Temperature-control device Control accuracy. (1100 ± 3) °C. Accuracy grade. not less than 0.2% FS. A.4 Thermocouple Type-S type or other conditional thermocouple, not lower than industrial grade- II, the thermocouple’s measuring end is located at the center of the coke layer. Note. The height of the coke layer changes with the density of the coke. During the test, adjust the position of the thermocouple’s measuring end according to the height of the coke in the reactor. A.5 Reactor (see Figure A.2) Reactor’s material. GH3044. Reactor’s wall-thickness. ≥ 1.5 mm. Reactor’s inner diameter. φ80 mm ± 1 mm. Reactor’s length. 500 mm. A.6 Testing system of coke reactivity index of single-point temperature- measuring heating-furnace The schematic diagram of the process flow of the testing system of coke reactivity index of the single-point temperature-measuring heating-furnace is as shown in Figure A.3. ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.