GB/T 37905-2019 PDF English
US$199.00 · In stock · Download in 9 secondsGB/T 37905-2019: Reclaimed water quality - Determination of chromium - Voltammetry and polarography Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedureStatus: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivery | Name of Chinese Standard | Status |
| GB/T 37905-2019 | English | 199 |
Add to Cart
|
3 days
|
Reclaimed water quality - Determination of chromium - Voltammetry and polarography
| Valid |
Excerpted PDFs (Download full copy in 9 seconds upon purchase)PDF Preview: GB/T 37905-2019
GB/T 37905-2019: Reclaimed water quality - Determination of chromium - Voltammetry and polarography ---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT37905-2019
(Water quality of reclaimed water - Determination of chromium voltamographic method)
ICS 13.060.50; 71.040.40
G76
National Standards of People's Republic of China
Determination of chromium in reclaimed water - Voltammetric polarography
Reclaimedwaterquality-Determinationofchromium-
Voltammetry andpolarography
Published on.2019-08-30
2020-07-01 implementation
State market supervision and administration
China National Standardization Administration issued
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard was proposed by the China Petroleum and Chemical Industry Federation.
This standard is under the jurisdiction of the National Chemical Standardization Technical Committee (SAC/TC63).
This standard was drafted. Tongji University, Henan Qingshuiyuan Technology Co., Ltd., Guangzhou Special Pressure Equipment Testing Institute, CNOOC
Tianjin Chemical Research and Design Institute Co., Ltd., Shenzhen Junnuo Testing Co., Ltd., Metrohm China Ltd., Chongqing University, Zhejiang Shuizhiyin
Environmental Protection Technology Co., Ltd., Tianjin Zhengda Technology Co., Ltd.
The main drafters of this standard. Wang Ying, Yang Haixing, Liu Juan, Li Lin, Wen Guanyong, Yu Hongwei, Zheng Huaili, Zhu Chunlian, Rong Xiuli, Shao Hongqian.
Determination of chromium in reclaimed water - Voltammetric polarography
1 Scope
This standard specifies the test method for total chromium, hexavalent chromium and trivalent chromium in reclaimed water--voltammetric polarography.
This standard applies to the determination of the mass concentration of chromium in reclaimed water, the measurement range is 1.0μg/L ~ 100μg/L. This standard also applies to
Determination of total chromium, hexavalent chromium and trivalent chromium in drinking water, surface water, sewage.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
Preparation of standard solution for GB/T 602 chemical reagent impurity determination
GB/T 6682 Analytical laboratory water specifications and test methods
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Pre-electrolysis pre-electrolysis
Under certain potential and agitation conditions, a certain period of time is prescribed to electrolyze and concentrate part of the analyte onto the working electrode.
3.2
Electrolyte electrolytetesolution
A solution used to dissolve a sample for voltammetric polarography.
3.3
Dissolution scan determination determinationofstrippingandsweep
After enrichment, the potential is changed from positive to negative, and the potential is changed linearly at a certain scanning rate. This process will be enriched to work electricity
The analyte on the electrode was dissolved and the stripping voltammetry curve was recorded.
3.4
Non-stoichiometric methodmethodnon-chemical
Under certain conditions, the analyte is partially electrolyzed and dissolved by a quantitative electrochemical reaction, and passed through the standard of electrolysis and dissolution under the same conditions.
The method of comparing the quasi-objects to calculate the content of the analyte.
4 Method summary
Using the principle of non-stoichiometry, the hexavalent chromium in the water sample reacts with diethylenetriaminepentaacetic acid (DTPA) to produce a certain product.
Within the current and voltage range, it is adsorbed and enriched on the suspended mercury electrode. When the electrode potential is uniformly scanned from the positive negative direction, the potential can be enriched
When the complex reacts, the metal complex enriched on the electrode forms ions into the solution, and the half-wave is utilized according to the obtained voltammetry curve.
The position was qualitatively analyzed, quantitative analysis was performed based on the peak height, and the content of the hexavalent chromium ion to be tested was calculated by the standard addition method. When measuring total chromium,
All chromium is first oxidized to hexavalent chromium in the presence of a strong oxidant and then measured. Trivalent chromium content from total chromium and hexavalent chromium
GB/T 37905-2019
(Water quality of reclaimed water - Determination of chromium voltamographic method)
ICS 13.060.50; 71.040.40
G76
National Standards of People's Republic of China
Determination of chromium in reclaimed water - Voltammetric polarography
Reclaimedwaterquality-Determinationofchromium-
Voltammetry andpolarography
Published on.2019-08-30
2020-07-01 implementation
State market supervision and administration
China National Standardization Administration issued
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard was proposed by the China Petroleum and Chemical Industry Federation.
This standard is under the jurisdiction of the National Chemical Standardization Technical Committee (SAC/TC63).
This standard was drafted. Tongji University, Henan Qingshuiyuan Technology Co., Ltd., Guangzhou Special Pressure Equipment Testing Institute, CNOOC
Tianjin Chemical Research and Design Institute Co., Ltd., Shenzhen Junnuo Testing Co., Ltd., Metrohm China Ltd., Chongqing University, Zhejiang Shuizhiyin
Environmental Protection Technology Co., Ltd., Tianjin Zhengda Technology Co., Ltd.
The main drafters of this standard. Wang Ying, Yang Haixing, Liu Juan, Li Lin, Wen Guanyong, Yu Hongwei, Zheng Huaili, Zhu Chunlian, Rong Xiuli, Shao Hongqian.
Determination of chromium in reclaimed water - Voltammetric polarography
1 Scope
This standard specifies the test method for total chromium, hexavalent chromium and trivalent chromium in reclaimed water--voltammetric polarography.
This standard applies to the determination of the mass concentration of chromium in reclaimed water, the measurement range is 1.0μg/L ~ 100μg/L. This standard also applies to
Determination of total chromium, hexavalent chromium and trivalent chromium in drinking water, surface water, sewage.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
Preparation of standard solution for GB/T 602 chemical reagent impurity determination
GB/T 6682 Analytical laboratory water specifications and test methods
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Pre-electrolysis pre-electrolysis
Under certain potential and agitation conditions, a certain period of time is prescribed to electrolyze and concentrate part of the analyte onto the working electrode.
3.2
Electrolyte electrolytetesolution
A solution used to dissolve a sample for voltammetric polarography.
3.3
Dissolution scan determination determinationofstrippingandsweep
After enrichment, the potential is changed from positive to negative, and the potential is changed linearly at a certain scanning rate. This process will be enriched to work electricity
The analyte on the electrode was dissolved and the stripping voltammetry curve was recorded.
3.4
Non-stoichiometric methodmethodnon-chemical
Under certain conditions, the analyte is partially electrolyzed and dissolved by a quantitative electrochemical reaction, and passed through the standard of electrolysis and dissolution under the same conditions.
The method of comparing the quasi-objects to calculate the content of the analyte.
4 Method summary
Using the principle of non-stoichiometry, the hexavalent chromium in the water sample reacts with diethylenetriaminepentaacetic acid (DTPA) to produce a certain product.
Within the current and voltage range, it is adsorbed and enriched on the suspended mercury electrode. When the electrode potential is uniformly scanned from the positive negative direction, the potential can be enriched
When the complex reacts, the metal complex enriched on the electrode forms ions into the solution, and the half-wave is utilized according to the obtained voltammetry curve.
The position was qualitatively analyzed, quantitative analysis was performed based on the peak height, and the content of the hexavalent chromium ion to be tested was calculated by the standard addition method. When measuring total chromium,
All chromium is first oxidized to hexavalent chromium in the presence of a strong oxidant and then measured. Trivalent chromium content from total chromium and hexavalent chromium
...... Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Tips & Frequently Asked QuestionsQuestion 1: How long will the true-PDF of English version of GB/T 37905-2019 be delivered?Answer: The full copy PDF of English version of GB/T 37905-2019 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice. Question 2: Can I share the purchased PDF of GB/T 37905-2019_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 37905-2019_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 37905-2019 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.
How to buy and download a true PDF of English version of GB/T 37905-2019?A step-by-step guide to download PDF of GB/T 37905-2019_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD). Step 2: Search keyword "GB/T 37905-2019". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9
|