HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (29 Sep 2024)

GB/T 37295-2019 PDF in English


GB/T 37295-2019 (GB/T37295-2019, GBT 37295-2019, GBT37295-2019)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 37295-2019English150 Add to Cart 0-9 seconds. Auto-delivery. Urban public facilities -- Requirements for security and protection system of electric vehicle charging/battery swap infrastructure Valid
Standards related to (historical): GB/T 37295-2019
PDF Preview

GB/T 37295-2019: PDF in English (GBT 37295-2019)

GB/T 37295-2019 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 29.200 K 81 Urban public facilities - Requirements for security and protection system of electric vehicle charging/battery swap infrastructure ISSUED ON: MARCH 25, 2019 IMPLEMENTED ON: OCTOBER 01, 2019 Issued by: State Market Regulatory Administration; Standardization Administration of PRC. Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Terms and definitions ... 5  4 General requirements ... 6  5 Charging station ... 8  7 Dispersal charging facilities ... 12  8 Management and maintenance requirements ... 12  Urban public facilities - Requirements for security and protection system of electric vehicle charging/battery swap infrastructure 1 Scope This standard specifies the general requirements for security and protection system of electric vehicle charging/battery swap infrastructure in urban public facilities, as well as the relevant requirements for the management and maintenance of charging stations, battery swap stations, dispersal charging facilities. This standard is applicable to the construction of security and protection systems such as video security monitoring, intrusion alarm, access control for the newly built, reconstructed, expanded electric vehicle charging/battery swap infrastructure in urban public facilities. 2 Normative references The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document. GB 16796 Safety requirements and test methods for security alarm equipment GB/T 29317 Terminology of electric vehicle charging/battery swap infrastructure GB/T 29781 General requirements for electric vehicle charging station GB 50348 Technical code for engineering of security and protection system GB 50394 Code of design for intrusion alarm systems engineering GB 50395 Code of design for video monitoring system GB 50396 Code of design for access control systems engineering Supervisory and control center The central control unit of the security system, wherein the security management system receives and processes the alarm information and status information sent by each subsystem, meanwhile sends the processed alarm information and monitoring instructions to the alarm receiving center and related subsystems respectively. 4 General requirements 4.1 Basic requirements 4.1.1 The security and protection system should be synchronously designed and constructed but independently accepted with the charging and swap facilities. 4.1.2 Electric vehicle charging and swap facilities shall be equipped with security and protection system according to the specific requirements of charging station, battery swap station, dispersal charging facilities. 4.1.3 The design of security and protection system shall follow the principles of security, stability, expandability, advanced technology, economical rationality, practicality and reliability, fully consider the characteristics of the charging and swap facilities and the importance of the protective objects, adopt corresponding protective measures, to build security and protection system. 4.1.4 The security technical indicators of the equipment and materials used in the security and protection system shall comply with the security performance requirements stipulated in GB 16796 and related product standards. 4.1.5 The security and protection system includes video security monitoring system, intrusion alarm system, access control system, which meets the relevant requirements of GB 50348. 4.1.6 The security and protection system shall realize the unified management of the video security monitoring system, the intrusion alarm system, the access control system. Each system shall be able to achieve linkage and operate independently. Failure of one system shall not affect the normal operation of other systems. 4.1.7 The security and protection system shall select the system and equipment with open communication protocol and interface, have good compatibility, can be integrated with the higher-level management organization, to realize remote centralized monitoring and management. 4.1.8 The security and protection system shall accept the time calibration of the security monitoring system, the access control system, and so on. 4.2.2.4 The intrusion alarm system shall be capable of arming/disarming in zones or independently. 4.2.2.5 The alarm signal sent shall be transmitted to the monitoring center. The alarm response time of the system shall not exceed 2 s. 4.2.2.6 The sound and light alarm shall be installed in a conspicuous place. When the intrusion detector is triggered, the sound and light alarm shall issue sound and light alarm. The indoor alarm sound pressure shall not be less than 80 dB, the outdoor alarm sound pressure shall not be less than 100 dB. The duration shall not be less than 2 min. 4.2.2.7 It shall be able to print alarm reports (including when, where, etc. the alarm occurred as well as the alarm type). 4.2.2.8 The emergency alarm device shall be concealed, easy to operate and clearly marked. 4.2.2.9 The system arming, disarming, alarming, and fault light information shall be stored for not less than 30 days and can be transferred to other storage media and output for printing. 4.2.3 Access control system 4.2.3.1 Conditional charging/battery swap facilities may be installed with access control systems, which shall comply with the relevant requirements of GB 50396. 4.2.3.2 The access control system includes functions such as storage, automatic acquisition, uninterrupted shooting, visual recognition, capture, access control identification, anti-smashing induction, voice broadcast. 4.2.3.3 The access control system is capable of storing at least 30 days of vehicle information records. When the maximum storage capacity is exceeded, it automatically overwrites vehicle information and pictures. 4.2.3.4 The access control system can accurately capture and record the traffic information of the passing vehicle. The recorded vehicle information includes information such as date, time (accurate to second), location, direction, license plate, color, etc. in addition to image information. 5 Charging station 5.1 Protection objects 7 Dispersal charging facilities 7.1 Video surveillance, intrusion alarm, access control of dispersal charging facilities shall make full use of the existing security and protection system in the area. 7.2 The video security monitoring system shall cover the relevant areas of the dispersal charging facilities. The protection requirements should refer to the requirements of 5.2.2.1, 5.2.2.2, 5.2.2.4. 7.3 Dispersal charging facilities should be equipped with an intrusion alarm system, to provide an alarm message for the intrusion of power distribution facilities and charging facilities. 7.4 Dispersal charging facilities which may be equipped with other security and protection devices shall be installed according to their own needs. 8 Management and maintenance requirements 8.1 Personnel requirements 8.1.1 The security and protection system shall be equipped with appropriate management and maintenance personnel. 8.1.2 Management and maintenance personnel shall have the corresponding qualifications and be proficient in the knowledge and skills of the operation and maintenance of the security and protection system. 8.1.3 Management and maintenance personnel shall be qualified after training. 8.2 System requirements 8.2.1 It shall clearly define a responsible person, establish and improve a security protection system such as safe operation procedures, daily inspections, special inspections. 8.2.2 It shall establish the emergency response plans for emergencies. 8.3 Operation/maintenance requirements 8.3.1 The system shall be inspected, overhauled, maintained, and serviced regularly to maintain a good operating state of the system and make relevant records. 8.3.2 It shall disclose the key security protection systems, operating procedures, related operational regulations. ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.