GB/T 29124-2025 (GB/T 29124-2012) PDF English
US$85.00 · In stock · Download in 9 secondsGB/T 29124-2012: Hydrogen fuel cell vehicles facilities for demonstration specifications Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedureStatus: Valid GB/T 29124: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivery | Name of Chinese Standard | Status |
GB/T 29124-2025 | English | 219 |
Add to Cart
|
3 days
|
Specifications for fuel cell electric vehicles facilities
| Valid |
GB/T 29124-2012 | English | 85 |
Add to Cart
|
0-9 seconds. Auto-delivery
|
Hydrogen fuel cell vehicles facilities for demonstration specifications
| Valid |
Excerpted PDFs (Download full copy in 9 seconds upon purchase)PDF Preview: GB/T 29124-2012
GB/T 29124-2012: Hydrogen fuel cell vehicles facilities for demonstration specifications---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT29124-2012
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 43.020
T 04
Hydrogen Fuel Cell Vehicles Facilities for
Demonstration – Specifications
Issued on: DECEMBER 31, 2012
Implemented on: JULY 1, 2013
Issued by. General Administration of Quality Supervision, Inspection and
Quarantine of the People's Republic of China;
Standardization Administration of the People's Republic of
China.
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Normative References ... 4
3 Terms and Definitions ... 4
4 Basic Conditions for Demonstration ... 5
5 Basic Requirements ... 5
6 Hydrogen Refueling Stations (Vehicles) and Hydrogen Refueling ... 6
7 Parking Lots and Maintenance Shops ... 7
Foreword
This Standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This Standard was proposed by the Ministry of Industry and Information Technology of
the People’s Republic of China.
This Standard shall be under the jurisdiction of the National Technical Committee of
Auto Standardization (SAC/TC 114).
The drafting organizations of this Standard. Tsinghua University and China Automotive
Technology & Research Center.
The main drafters of this Standard. Chen Quanshi, Zhu Jialian, He Yuntang and Tian
Guangyu.
Hydrogen Fuel Cell Vehicles Facilities for
Demonstration – Specifications
1 Scope
This Standard specifies the terms and definitions of compressed hydrogen fuel cell
vehicles facilities for demonstration, basic conditions for demonstration, basic
requirements, hydrogen refueling stations (vehicles) and hydrogen refueling, and
relevant specifications for parking lots and maintenance shops.
This Standard applies to hydrogen refueling stations, parking lots and maintenance
shops for hydrogen fuel cell vehicles for demonstration (hereinafter referred to as
vehicles) whose compressed hydrogen system’s rated working pressure is not greater
than 35 MPa.
2 Normative References
The following documents are essential to the application of this standard. For dated
references, only the dated editions apply to this standard. For undated references, the
latest edition (including all amendments) applies to this standard.
GB/T 24548 Fuel Cell Electric Vehicles – Terminology
GB 50177 Design Code for Hydrogen Station
QC/T 816-2009 Specification of Mobile Hydrogen Refueling Vehicles
3 Terms and Definitions
The following terms and definitions and those defined in GB/T 24548 apply to this
document.
3.1 Facilities for demonstration
Facilities for demonstration refer to hydrogen refueling stations, parking lots and
maintenance shops and others required for demonstration.
3.2 Hydrogen vent pipe
Hydrogen vent pipe refers to a special hydrogen vent channel which is fixed in a
building and used for vehicles to discharge hydrogen indoors.
5.6 Do not discharge hydrogen indoors; if purging, replacement, emptying for
depressurization or other operations is carried out indoors for hydrogen systems,
hydrogen vent pipes shall be used to discharge hydrogen outdoors safely.
5.7 In case of a leakage or concentration of hydrogen, immediately cut off the gas
source; ventilate the room; and do not carry out any operation that may generate
sparks.
5.8 If an open flame needs to be used for vehicles or hydrogen systems, it shall be
guaranteed that the concentration of hydrogen inside of hydrogen systems within hot
work area does not exceed its lower flammability limit.
5.9 When a hydrogen leakage test is carried out for the pipes, valves, joints and
others of hydrogen systems, apparatus and method shall be used as specified.
6 Hydrogen Refueling Stations (Vehicles) and
Hydrogen Refueling
6.1 Management of hydrogen refueling stations (areas)
6.1.1 Conspicuous barriers between hydrogen refueling stations (areas) and the
outside world as well as clear entrances and exits shall be provided.
6.1.2 Smoking or use of open flame are prohibited; if an open flame must be used
because equipment maintenance etc., a hot work can only be done after it is approved,
relevant rules shall be followed, reliable safety measures shall be taken.
6.1.3 Spacing between vehicles within hydrogen refueling stations (areas) shall meet
the criteria of emergency evacuation.
6.2 Hydrogen refueling operation
6.2.1 Before hydrogen refueling, fuel cell systems and vehicles’ high voltage systems
shall be shut down; and vehicles shall be earthed at hydrogen refueling stations
(unless that the manufacturer of vehicles declares that earthing is not necessary).
6.2.2 The following rules shall be followed during hydrogen refueling operation.
6.2.2.1 In case of adverse weather such as strong lightning or an emergency adverse
to hydrogen refueling safety that occurs inside or outside of hydrogen refueling stations,
follow the rules of the Safety Accidents Emergency Response Plan for Demonstration,
stop hydrogen refueling operation and shut down power sources and gas sources.
6.2.2.2 When vehicles get in a station for hydrogen refueling, drivers shall follow
relevant rules for hydrogen refueling stations.
...... Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
|