Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 223.63-2022English230 Add to Cart 0-9 seconds. Auto-delivery. Iron, steel and alloy - Determination of manganese content - Sodium (potassium) periodate spectrophotometric method Valid
GB/T 223.63-1988English85 Add to Cart 0-9 seconds. Auto-delivery. Methods for chemical analysis of iron, steel and alloy - The sodium (potassium) periodate photometric method for the determination of manganese content Obsolete
Standards related to (historical): GB/T 223.63-2022
PDF Preview

GB/T 223.63-2022: PDF in English (GBT 223.63-2022)

GB/T 223.63-2022 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 77.080.01 CCS H 11 Replacing GB/T 223.63-1988 Iron, Steel and Alloy - Determination of Manganese Content - Sodium (potassium) Periodate Spectrophotometric Method (ISO 629:1982, Steel and Cast Iron - Determination of Manganese Content - Spectrophotometric Method, NEQ) ISSUED ON: JULY 11, 2022 IMPLEMENTED ON: FEBRUARY 1, 2023 Issued by: State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of Contents Foreword ... 3 Introduction ... 5 1 Scope ... 6 2 Normative References ... 6 3 Terms and Definitions ... 7 4 Principle ... 7 5 Reagents or Materials ... 7 6 Instruments and Equipment ... 9 7 Sample ... 9 8 Test Procedures ... 9 9 Processing of Test Data ... 12 10 Precision ... 12 11 Test Report ... 13 Appendix A (informative) Constituent Documents of GB/T 223 ... 14 Appendix B (informative) Relevant Information of Precision Test ... 20 Iron, Steel and Alloy - Determination of Manganese Content - Sodium (potassium) Periodate Spectrophotometric Method WARNING---the personnel using this document shall have practical experience in formal laboratory work. This document does not point out all possible safety issues. It is the user’s responsibility to take appropriate safety and health measures and ensure the compliance with the conditions stipulated in the relevant national laws and regulations. 1 Scope This document specifies the method for the determination of manganese content in iron, steel and alloy by the sodium (potassium) periodate spectrophotometric method. This document is applicable to the determination of manganese content in iron, steel, high- temperature alloy and precision alloy. The range of determination is: 0.001% ~ 4.00%. 2 Normative References The contents of the following documents constitute indispensable clauses of this document through the normative references in the text. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document. GB/T 6379.1 Accuracy (trueness and precision) of Measurement Methods and Results - Part 1: General Principles and Definitions GB/T 6379.2 Accuracy (trueness and precision) of Measurement Methods and Results - Part 2: Basic Method for the Determination of Repeatability and Reproducibility of a Standard Measurement Method GB/T 7729 Chemical Analysis of Metallurgical Products - General Rule for Spectrophotometric Methods GB/T 12805 Laboratory Glassware - Burettes GB/T 12806 Laboratory Glassware - One-mark Volumetric Flasks GB/T 12808 Laboratory Glassware - One-mark Pipettes GB/T 20066 Sample and Iron - Sampling and Preparation of Samples for the Determination of Chemical Composition 3 Terms and Definitions This document does not have terms or definitions that need to be defined. 4 Principle After the specimen is dissolved in acid, in sulfuric acid and phosphoric acid medium, use sodium (potassium) periodate to oxidize manganese to heptavalent; at a wavelength of 530 nm, use a spectrophotometer to measure the absorbance. 5 Reagents or Materials Unless it is otherwise specified, only reagents confirmed to be analytically pure, as well as distilled water or deionized water (or water of equivalent purity) are used in the analysis. 5.1 Hydrofluoric Acid ρ is about 1.15 g/mL. 5.2 Hydrochloric Acid ρ is about 1.19 g/mL. 5.3 Nitric Acid ρ is about 1.42 g/mL. 5.4 Nitric Acid, 1 + 4 Dilute with nitric acid (5.3). 5.5 Sulfuric Acid, 1 + 1 Dilute with sulfuric acid with ρ about 1.84 g/mL. 5.6 Perchloric Acid, 1 + 499 Dilute with perchloric acid with ρ about 1.67 g/mL. 5.7 Phosphoric Acid - Perchloric Acid Mixed Acid Mix three portions of phosphoric acid (ρ about 1.69 g/mL) and one portion of perchloric acid (ρ about 1.67 g/mL). 5.8 Sodium (potassium) Periodate Solution, 50 g/L Weigh-take 5 g of sodium periodate or potassium periodate and place in a 250 mL beaker; add 60 mL of water and 20 mL of nitric acid (see 5.3), warm to dissolve it, then, cool it. Use water to dilute to 100 mL and mix it well. 5.9 Sodium Nitrite Solution, 10 g/L Weigh-take 1 g of sodium nitrite, place in a 250 mL beaker, add 60 mL of water to dissolve it, then, use water to dilute to 100 mL and mix it well. 5.10 Manganese Standard Solution 5.10.1 Manganese standard solution, 500 g/mL Weigh-take 1.4383 g of potassium permanganate (mass fraction not less than 99.9%) and place in a 600 mL beaker; add 300 mL of water to dissolve it, add 10 mL of sulfuric acid (see 5.5) and dropwise add hydrogen peroxide (ρ about 1.10 g/mL), until the red color just disappears; heat to boil for 5 min ~ 10 min, then, cool it. Transfer it to a 1,000 mL volumetric flask; use water to dilute to the mark and mix it well. Alternatively, weigh-take 0.5000 g of electrolytic manganese (mass fraction not less than 99.9%) [electrolytic manganese needs to be cleaned in sulfuric acid (5 + 95) in advance, and after manganese oxide on the surface is cleaned, take it out, immediately use distilled water to repeatedly wash it, then, wash it in absolute ethanol for 4 ~ 5 times, take it out and dry it in a desiccator before use] and place in a 250 mL beaker; add 20 mL of nitric acid (1 + 3), heat to dissolve it and boil to drive out nitrogen oxides; remove and cool it to room temperature. Then, transfer to a 1,000 mL volumetric flask, use water to dilute to the mark and mix it well. 1 mL of this standard solution contains 500 g of manganese. 5.10.2 Manganese standard solution, 100 g/mL Weigh-take 20.0 mL of manganese standard solution (see 5.10.1) and place in a 100 mL volumetric flask; use water to dilute to the mark and mix it well. 1 mL of this standard solution contains 100 g of manganese. 5.10.3 Manganese standard solution, 20 g/mL Weigh-take 20.0 mL of manganese standard solution (see 5.10.2) and place in a 100 mL volumetric flask; use water to dilute to the mark and mix it well. 1 mL of this standard solution contains 20 g of manganese. 5.11 Water without Reducing Substances Heat distilled water or deionized water to boil, use 10 mL of sulfuric acid (1 + 3) to acidify each liter; add a few granules of sodium (potassium) periodate and continue to boil for 1 min ~ 2 min, cool it before use. reaction stops. Add 1 mL ~ 2 mL of hydrochloric acid (see 5.2), and continue heating, until it is completely decomposed. ---For high-nickel-chromium specimens, add 10 mL of (3 + 1), (6 + 1) or (10 + 1) mixed acid of hydrochloric acid (see 5.2) and nitric acid (see 5.3), heat at low temperature to dissolve it. NOTE: when the amount of specimen is 2 g, depending on the situation, the amount of acid can be increased, so that the specimen can be completely dissolved. Add 10 mL of phosphoric acid - perchloric acid mixed acid (see 5.7) [when the amount of specimen is 2.0 g, add 15 mL of phosphoric acid - perchloric acid mixed acid (see 5.7); when using 15 mL of phosphoric acid - perchloric acid mixed acid (see 5.7) to dissolve high-tungsten specimens, it is not necessary to add], heat and evaporate it, until perchloric acid fumes are emitted for 2 min ~ 5 min (for specimens with high chromium content, the chromium needs to be oxidized); slightly cool and add water to dissolve salts. If necessary, remove graphitic carbon by filtration and use hot perchloric acid (see 5.6) to wash it. ---When the manganese content is not greater than 2.00%, add 10 mL of sulfuric acid (see 5.5) and use water to dilute to about 40 mL. ---When the manganese content is greater than 2.00%, add 10 mL of sulfuric acid (see 5.5) and use water to dilute to about 40 mL; cool to room temperature, then, transfer to a 100 mL volumetric flask; use water to dilute to the mark and mix it well. Transfer-take 50.0 mL of test solution in a 150 mL conical flask, additionally add 5 mL of sulfuric acid (see 5.5). 8.2.2 Color development In the test solution prepared in 8.2.1, add 10 mL of sodium (potassium) periodate solution (see 5.8), heat to boil and maintain it for 2 min ~ 3 min (to prevent the test solution from splashing out); cool to room temperature and transfer to a 100 mL volumetric flask; use water without reducing substances (see 5.11) to dilute it to the mark and mix it well. 8.2.3 Preparation of reference solution Transfer-take about 25 mL of chromogenic solution (see 8.2.2) to a 100 mL conical flask; while shaking it, dropwise add sodium nitrite solution (see 5.9), until the purple color just fades (see NOTE). Use this solution as the reference solution. NOTE: when the cobalt-containing specimen is faded with sodium nitrite solution, the reddish color of cobalt will not fade, and it can be handled in accordance with the following method: constantly shake the volumetric flask, slowly and dropwise add sodium nitrite solution (see 5.9), if the reddish color of the specimen remains unchanged, put the solution in an absorption vessel and measure its absorbance; add sodium nitrite solution (see 5.9) to the remaining test solution, then, measure the absorbance again, until there is no change in the absorbance. 9 Processing of Test Data Utilize the calibration curve (see 8.2.5.2) to convert the absorbance to the mass of manganese in the corresponding test solution, expressed in g. The manganese content (wMn), which is expressed in mass fraction (%), shall be calculated in accordance with Formula (1): Where, m1---the mass of manganese obtained from the calibration curve, expressed in (g); m---the amount of specimen, expressed in (g); V---the total volume of the test solution, expressed in (mL); V1---the volume of the divided test solution, expressed in (mL). 10 Precision The precision test in this document was performed by 10 laboratories on 10 levels of manganese content. Each laboratory determines each level of manganese content twice under the repeatability conditions specified in GB/T 6379.1. See Table B.1 of Appendix B for the specimens used. See Table B.2 of Appendix B for the original data of the precision test. In accordance with GB/T 6379.2, conduct statistical analysis on the obtained results. The results suggest that there is a logarithmic relation between the manganese content and the repeatability limit (r) and reproducibility limit (R) of the test results, which are summarized in Table 3. The repeatability limit (r) and reproducibility limit (R) are obtained through the equation provided in Table 3. Under repeatability conditions, the absolute difference of the obtained two independent ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.