Powered by Google www.ChineseStandard.net Database: 189760 (25 May 2024)

GB/T 13354-1992 PDF in English


GB/T 13354-1992 (GB/T13354-1992, GBT 13354-1992, GBT13354-1992)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 13354-1992English70 Add to Cart 0-9 seconds. Auto-delivery. Test method for density of adhesives in fluid form. Method of weight cup


Standards related to: GB/T 13354-1992

GB/T 13354-1992: PDF in English (GBT 13354-1992)

GB/T 13354-1992
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
Test Method for Density of Adhesives in Fluid Form –
Method of Weight Cup
ISSUED ON: JANUARY 14, 1992
IMPLEMENTED ON: DECEMBER 01, 1992
Issued by: State Bureau of Technical Supervision
Table of Contents
1 Subject Contents and Applicable Scope ... 3
2 Definition ... 3
3 Apparatus ... 3
4 Test Procedures ... 3
5 Method of Calculation ... 4
6 Test Report ... 4
Additional Information: ... 5
Test Method for Density of Adhesives in Fluid Form –
Method of Weight Cup
1 Subject Contents and Applicable Scope
This Standard specifies the method for measuring the density of liquid adhesives and
their components by a 37.00mL weight cup.
This Standard is applicable to the determination of the density of liquid adhesives;
especially for liquid adhesives whose viscosity is higher or the components are more
volatile, and it is not appropriate to use the pycnometer method to determine the
density.
2 Definition
Density: The mass per unit volume of the liquid adhesive at a specified temperature
(weight in a vacuum). The density in this method is obtained through dividing the mass
of the liquid adhesive in a weight cup with a capacity of 37.00 mL at 20°C by 37.00mL.
3 Apparatus
3.1 Weight cup: a metal cup with a capacity of 37.00 mL at 20°C.
NOTE: The domestically-produced weight cup that satisfies this Standard is called "QBB
Specific Gravity Cup".
3.2 Constant temperature bath or constant temperature room: Can maintain at 23±1°C.
3.3 Balance: Sensitivity is 0.001g.
3.4 Thermometer: 0~50°C, with division of 1°C.
4 Test Procedures
4.1 Prepare an adhesive sample sufficient for three tests.
4.2 Wash the weight cup by a volatile solvent and dry it.
......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.