HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (12 Oct 2025)

GB/T 11892-1989 PDF English

US$90.00 · In stock · Download in 9 seconds
GB/T 11892-1989: Water quality. Determination of permanganate index
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
GB/T 11892-1989English90 Add to Cart 0-9 seconds. Auto-delivery Water quality. Determination of permanganate index  

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: GB/T 11892-1989
      

Similar standards

GB/T 11893   GB/T 11896   GB/T 11901   GB/T 36084   

GB/T 11892-1989: Water quality. Determination of permanganate index

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT11892-1989
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA Water quality - Determination of permanganate index Issued on: DECEMBER 25, 1989 Implemented on: JULY 1, 1990 Issued by. National Environmental Protection Authority

Table of Contents

1 Subject and scope ... 3 2 Definition ... 3 3 Principle... 4 4 Reagents ... 4 5 Apparatus ... 5 6 Sample storage ... 5 7 Analysis steps ... 5 8 Expression of results ... 6 9 Precision... 7 Annex A (Supplement) Alkaline potassium permanganate oxidation method .. 8 Additional information ... 8 Water quality - Determination of permanganate index This Standard refers to the International Standard ISO 8467-1986 Water quality -- Determination of permanganate index.

1 Subject and scope

1.1 Subject This Standard specified the method for determination of permanganate index in water. 1.2 Scope This Standard is applicable to the determination of drinking water, water-source water and ground water. The determination scope is 0.5 ~ 4.5 mg/L. For heavy-polluted water, it shall take few water sample for determination after dilution. This Standard is not applicable to the determination of the amount of organic pollution in industrial waste. If the determination is required, potassium dichromate can be used to determine the chemical oxygen demand. The inorganic reducing substances in sample such as , S2- and Fe2+ can be determined. When chloride ion concentration is greater than 300 mg/L, it shall use the method for the determination of oxidation in alkaline media.

2 Definition

The permanganate index is a common indicator of the contamination of organic and inorganic oxidizable substances in water. It is defined as. under certain conditions, the equivalent amount of oxygen calculated by the potassium permanganate content consumed by using certain organic and inorganic reducing substances in potassium permanganate oxidizes water sample. The permanganate index can not be used as an indicator of theoretical oxygen demand or total organic matter content because under certain conditions, many organic matters can only be partially oxidized; volatile organic matter is not included in the measured value. 4.8 Potassium permanganate standard solution, concentration C3 (1/5 KMnO4) of about 0.01 mol/L. pipet 100 mL of potassium permanganate standard stock solution (4.7) in a 1000 mL volumetric flask; use water to dilute to the scale; well mix. This solution can be stored in the dark for several months. Use the same day to calibrate its concentration.

5 Apparatus

5.1 Commonly used laboratory instruments and the following instruments. 5.2 Water bath or equivalent heating device. with enough volume and power. 5.3 Acid burette, 25 mL. NOTE The new glassware must be cleaned with acidic potassium permanganate solution.

6 Sample storage

After sampling, add sulfuric acid (4.3) to make sample pH 1~2 and analyze as soon as possible. If the storage time exceeds 6h, it needs storing in a dark place at 0~5°C. Must not exceed 2 days.

7 Analysis steps

7.1 Pipet 100.0 mL of sample that has been thoroughly shaken and well mixed (or pipet appropriate amount for several times; use water to dilute to 100 mL). Place in a 250 mL conical flask. Add 5 ± 0.5 mL of sulfuric acid (4.3). Use a burette to add 10.00 mL of potassium permanganate standard solution (4.8). Shake well. Place the conical flask in a boiling water bath for 30 min (starts timing when water bath boils). 7.2 After removal, use a burette to add 10 mL of sodium oxalate solution (4.6) till the solution turns colorless. When it is still heated, use potassium permanganate solution (4.8) to titrate till pink just appears and maintain for 30s. Record the volume of potassium permanganate solution consumed. 7.3 Blank test. use 100 mL of water to replace sample; determine according to 7.1, 7.2; record the volume of potassium permanganate solution dropped (4.8). 7.4 Add 10.00 mL of sodium oxalate solution (4.6) into the solution that has been titrated by the blank test (7.3). If necessary, heat the solution to 80°C. Use potassium permanganate solution (4.8) to carry out the continuous titration till pink just appears and maintain for 30s. Record the volume of ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of GB/T 11892-1989 be delivered?

Answer: The full copy PDF of English version of GB/T 11892-1989 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB/T 11892-1989_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 11892-1989_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- GB/T 11892-1989 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of GB/T 11892-1989?

A step-by-step guide to download PDF of GB/T 11892-1989_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB/T 11892-1989".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9