HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (23 Mar 2025)

GB 26386-2011 PDF English


Search result: GB 26386-2011
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB 26386-2011English190 Add to Cart 0-9 seconds. Auto-delivery. General safety technical specification for burnable incense Valid


PDF Preview: GB 26386-2011


GB 26386-2011: PDF in English

GB 26386-2011 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 13.120 Y 40 General safety technical specification for burnable incense ISSUED ON: MAY 12, 2011 IMPLEMENTED ON: SEPTEMBER 15, 2011 Issued by: General Administration of Quality Supervision, Inspection and Quarantine of PRC; Standardization Administration of PRC. Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Terms and definitions ... 4  4 Categories... 5  5 Requirements ... 5  6 Test method ... 6  7 Inspection rules ... 7  8 Marking, packaging, transportation, storage ... 8  Appendix A (Normative) Test method of soot amount of burnable incense products ... 10  General safety technical specification for burnable incense 1 Scope This standard specifies the terms and definitions, classification, requirements, test methods, markings, packaging, transportation, storage of burnable incense products. This standard applies to solid incense, which is used in public places, such as religion, etiquette, sacrifices, AND to improve indoor and outdoor environments. 2 Normative references The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) is applicable to this standard. GB/T 191 Packaging - Pictorial marking for handling of goods GB/T 2828.1-2003 Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection GB/T 2829-2002 Sampling procedures and tables for periodic inspection by attributes (Apply to inspection of process stability) GB/T 26393 Test methods for harmful matter of burnable incense 3 Terms and definitions The following terms and definitions apply to this document. 3.1 Odor type It is used to describe the overall aroma type in burnable incense products, such as sandalwood, jasmine, rose, etc. e) Specification and quantity; f) Inspection conformity mark; g) Precautions and warning words, such as: "Be careful after lighting." 8.1.2 The product packaging box shall have the following Chinese signs: a) Product name; b) The name and address of manufacturer; c) Specification and quantity; d) Pictorial signs for storage and transportation. 8.1.3 The pictorial signs for, packaging, transportation, storage shall meet the requirements of GB/T 191. 8.2 Packaging The packaging shall be firm, free from damage, squeezing and moisture proof. 8.3 Transportation The product shall be protected from rain and snow, during transportation. When handling, please load and unload with care; don't press it heavily. 8.4 Storage The product is stored in a ventilated and dry place; kept away from fire sources during storage; the distance between the stacking position and the ground and the wall is not less than 20 cm. A.3.1 Temperature: (23 ± 5) °C. A.3.2 Relative humidity: (65 ± 15)%. A.4 Test procedure A.4.1 Sample test Place the sample to be tested and the filter paper in a drier, for 4 hours. Start the test (it needs removing the exposed bamboo part from the bamboo incense). Use an analytical balance to weigh the filter paper, as m1 (accurate to 0.1 mg). Fix it on the sampling head. The sampling head is installed at the center of the upper cover of the smoke collection tube. Cut 0.6 g from the sample to be tested, accurate to 0.1 mg. Weigh its mass m, as the sample to be tested. It can be cut into multiple segments as needed, BUT it must be ignited at the same time. Adjust the sampling gas flowmeter to 5 L/min. Ignite the sample to be tested. Immediately put it in the smoke collection tube. Place it at the center of the bottom of the tube. Align it with the sampling head. The distance between the sampling filter paper and the sample to be tested is 10 cm. After the test sample is burned out, remove the filter paper. Put it in the drier. After 1 h, use an analytical balance to weigh its mass, as m2 (accurate to 0.1 mg). Record the time from ignition to burnout, as t. A.4.2 Blank test Take a piece of filter paper. Use an analytical balance, to weigh its mass, as m3 (accurate to 0.1 mg). Fix the filter paper on the sampling head. Install the sampling head, at the center of the upper cover of the smoke collection tube. Adjust the flowmeter to 5 L/min; the collection time is t (A.4.1). After collection, remove the filter paper. Put it in a drier. After 1 hour, use an analytical balance to weigh its mass, as m4 (accurate to 0.1 mg). A.5 Calculation The amount of soot of the tested sample is calculated, according to formula (A.1): Where: X - The amount of soot, in milligrams per gram (mg/g); m1 - The mass of the filter paper, before sampling, for the sample test, in grams (g); ......
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.