HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (11 Jan 2025)

GB/T 26393-2011 PDF English


Search result: GB/T 26393-2011_English: PDF (GB/T26393-2011)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 26393-2011English130 Add to Cart 0-9 seconds. Auto-delivery. Test methods for harmful matter of burnable incense Valid
BUY with any currencies (Euro, JPY, GBP, KRW etc.): GB/T 26393-2011     Related standards: GB/T 26393-2011

PDF Preview: GB/T 26393-2011


GB/T 26393-2011: PDF in English (GBT 26393-2011)

GB/T 26393-2011 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 13.120 Y 40 Test methods for harmful matter of burnable incense ISSUED ON: MAY 12, 2011 IMPLEMENTED ON: SEPTEMBER 15, 2011 Issued by: General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the People’s Republic of China. Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Reagents and materials ... 4  4 Instruments ... 5  5 Test of migration ... 5  6 Test of the concentration of formaldehyde, benzene, toluene and xylene after combustion ... 7  7 Test of total volatile organic compound (TVOC) concentration after combustion ... 8  Appendix A (Normative) Standard solution concentration ... 9  Test methods for harmful matter of burnable incense 1 Scope This Standard specifies test methods for the content of migration in burnable incense and the concentration of formaldehyde, benzene, toluene, xylene, and total volatile organic compounds after combustion. This Standard applies to the determination of harmful matter of solid incense used in public places such as religious, etiquette, sacrificial, and other indoor and outdoor environments. 2 Normative references The following documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 6682-2008, Water for analytical laboratory use - Specification and test methods GB/T 11737-1989, Standard method for examination of benzene toluene and xylene in air of residential areas - Gas chromatography GB/T 15516-1995, Air quality - Determination of formaldehyde - Acetylacetone spectrophotometric method GB 50325-2001, Code for indoor environmental pollution control of civil building engineering 3 Reagents and materials 3.1 Water: Grade-3 water which is specified in GB/T 6682-2008. 3.2 Hydrochloric acid: analytical reagent, 36.0% ~ 38.0%. 3.3 0.07 mol/L hydrochloric acid solution: absorb 5.8 mL of hydrochloric acid; use water to dilute to 1 000 mL. 3.4 2 mol/L hydrochloric acid solution: absorb 16.6 mL of hydrochloric acid; use water to dilute to 100 mL. Use a pulverizer to crush 20 g of sample (for the bamboo incense, remove the bamboo core first); then, pass it through a 0.180 mm (80 mesh/inch) standard sieve; mix well; divide the prepared sample into two equal parts, one for the sample, another one to be tested. 5.1.2 Extraction of sample Weigh 2 g of sample into a 250 mL Erlenmeyer flask with stopper; put 0.07 mol/L hydrochloric acid solution in a constant temperature water bath oscillator to preheat to 37 °C; transfer 100 mL into the above-mentioned Erlenmeyer flask with stopper; shake for 1 min; use 2 mol/L hydrochloric acid solution to adjust the pH to 1.0 ~ 1.5. Shake in the constant temperature water bath oscillator at 37 °C for 1 h under dark conditions; then, stand still in a water bath at 37 °C for 1 h. Take the supernatant and filter for testing. If necessary, centrifugal separation can be performed at a speed of 2 000 r/min. The separation shall be completed as soon as possible after the above-mentioned storage time, and the time of centrifugation shall not exceed 10 min. The extracted filtrate must be analyzed and tested within 1 working day. At the same time, prepare a blank sample according to the same procedure. 5.2 Test of sample solution Use an inductively coupled plasma emission spectrometer to test each standard solution in turn from low concentration to high concentration; draw the concentration-absorbance standard curve. Test the absorbance of the sample solution and the blank sample solution; read the corresponding migration concentration from the standard curve. 5.3 Calculation After testing the concentration of the migration in the sample solution and the blank sample solution, calculate the content of the migration in the sample according to Formula (1). Where: X – the content of migration in the sample, in milligrams per kilogram (mg/kg); c1 – the concentration of migration in the sample solution read from the standard curve, in milligrams per liter (mg/L); c0 – the concentration of migration in the blank solution read from the standard curve, in milligrams per liter (mg/L); V – the volume of the sample solution, in milliliters (mL), which is 100 according to this method; m – sample mass, in grams (g). 5.4 Result processing The absolute difference between the two parallel test results is not more than 10% of the arithmetic mean of the two measured values, otherwise, it needs to be sampled and tested again. Take the average of the two parallel test results. 6 Test of the concentration of formaldehyde, benzene, toluene and xylene after combustion 6.1 Test conditions Set a sample point in a closed room of (45±2) m3; the center of location in the room is shown in Figure 1a). The sampling point shall be kept away from vents, and the distance from the wall shall be greater than 0.5 m. The height of the sampling point, in principle, shall be consistent with the height of the human breathing belt; the relative height shall be at 0.5 m ~ 1.5 m. 6.2 Test method Connect the atmospheric sampler to the porous glass absorption tube and the activated carbon sampling tube; place and evenly distribute them on the diagonal of the room, as shown in Figure 1a); ignite the incense whose mass is (0.6±0.020) g (the mass of bamboo incense is calculated according to the mass after removing the bamboo core); start sampling after the sample is ignited; close the doors and windows during sampling. Perform sampling for 45 minutes at a flow rate of 0.5 L/min. For the collected gas, test the concentration of formaldehyde after combustion according to the method of GB/T 15516-1995; test the concentration of benzene, toluene, and xylene after combustion according to the method of GB/T 11737-1989 method. Take the average of the test results of the three sampling points. Before each sampling, take a blank sample for analysis in the same way as the sample. ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.