GB 1886.350-2021 PDF English
US$170.00 · In stock · Download in 9 secondsGB 1886.350-2021: [Including 2025XG1] National food safety standard - Food additives - Nitrous Oxide Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedureStatus: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivery | Name of Chinese Standard | Status |
| GB 1886.350-2021 | English | 170 |
Add to Cart
|
0-9 seconds. Auto-delivery
|
[Including 2025XG1] National food safety standard - Food additives - Nitrous Oxide
| Valid |
Excerpted PDFs (Download full copy in 9 seconds upon purchase)PDF Preview: GB 1886.350-2021
GB 1886.350-2021: National food safety standard - Food additives - Nitrous Oxide---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB1886.350-2021
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
National Food Safety Standard - Food Additives -
Nitrous Oxide
ISSUED ON: SEPTEMBER 07, 2021
IMPLEMENTED ON: MARCH 07, 2022
Issued by: National Health Commission;
State Administration for Market Regulation.
Table of Contents
1 Scope ... 3
2 Chemical name, molecular formula, structural formula and relative molecular
mass ... 3
3 Technical requirements ... 3
Annex A Inspection methods ... 5
National Food Safety Standard - Food Additives -
Nitrous Oxide
1 Scope
This Standard applies to nitrous oxide, a food additive obtained by thermal
decomposition using ammonium nitrate as a raw material.
2 Chemical name, molecular formula, structural
formula and relative molecular mass
2.1 Chemical name
Nitrous oxide (nitrous oxide).
2.2 Molecular formula
N2O
2.3 Structural formula
N-N-O
2.4 Relative molecular mass
44.01 (according to 2018 international relative atomic mass)
3 Technical requirements
3.1 Sensory requirements
Sensory requirements shall meet the requirements of Table 1.
Annex A
Inspection methods
WARNING: Some procedures specified in the test method may lead to
dangerous situations. The operator shall take appropriate safety and
protective measures. During the test, there shall be nitrous oxide tail gas
treatment measures.
A.1 General
The reagents and water used in this Standard refer to analytically-pure reagents
and grade 3 water specified in GB/T 6682 when other requirements are not
indicated. The solution used in the test refers to an aqueous solution when it is
not specified which solvent is used to prepare it.
A.2 Identification test
A.2.1 Method principle
Nitrous oxide can make red wood sticks ignite and burn. But when it passes
into alkaline pyrogallic acid solution, the solution will not turn brown.
A.2.2 Reagents and materials
A.2.2.1 Wooden sticks.
A.2.2.2 Pyrogallic acid (1,2,3-pyrogallol).
A.2.2.3 Potassium hydroxide.
A.2.2.4 Alkaline pyrogallic acid solution: Take 0.5g of pyrogallic acid (1,2,3-
pyrogallol). Add 2mL of water to dissolve. Shake well to obtain solution A. Take
12g of potassium hydroxide. Add 8mL of water to dissolve. Shake well to obtain
solution B (saturated potassium hydroxide solution). Mix the two solutions A and
B immediately before use. It shall be prepared in a vacuum glove box.
A.2.3 Instruments and equipment
Vacuum glove box.
A.2.4 Analysis steps
A.2.4.1 Connect the sample gas to the gas pressure reducing valve. Open the
valve. Pour gas into a clean reagent bottle. Close the gas sampling valve.
Quickly cover the reagent bottle with a watch glass. Then put the red wood
sticks into the reagent bottle containing nitrous oxide gas. Wooden sticks can
A.5.2 Reagents and materials
A.5.2.1 Chromatographic carrier gas: High-purity helium gas, whose purity
should be greater than 99.999%.
A.5.2.2 Standard sample: Use helium with a purity greater than 99.9999% as
the bottom gas. The oxygen content (volume fraction) is 0.2%, and the nitrogen
content (volume fraction) is 0.8%.
A.5.3 Instruments and equipment
Gas chromatograph: Equipped with thermal conductivity detector.
A.5.4 Reference chromatographic conditions
A.5.4.1 Chromatographic column: Stainless steel tube with a length of about
1.5m and an inner diameter of 2mm, with a 13X molecular sieve with a particle
size of 0.25mm~0.4mm, or other equivalent chromatographic columns.
A.5.4.2 Carrier gas flow (He >99.999%): 10mL/min.
A.5.4.3 Detector temperature: 160°C.
A.5.4.4 Oven temperature: 30°C.
A.5.4.5 Makeup gas flow rate: 5.0mL/min.
A.5.5 Determination steps
A.5.5.1 Preparation
Turn on the instrument according to the instrument manual. Set various
operating parameters of the instrument until the instrument works normally.
A.5.5.2 Calibration
Connect the standard sample to the instrument through the sampling tube. Turn
on the sample to fully purge the sampling system until a representative sample
is obtained. Switch the sampling valve to inject samples into the instrument.
Measure the response value of the instrument (peak area or peak height).
Repeat the injection at least 2 times, until the relative deviation of the response
value is less than 5%. Take the average value As.
A.5.5.3 Determination
Perform under exactly the same conditions as the calibration. Connect the
sample gas to the instrument through the sampling tube. Turn on the sample to
fully purge the sampling system until a representative sample is obtained.
Switch the sampling valve to inject samples into the instrument. Measure the
A.7 Determination of ammonia
A.7.1 Method principle
When a certain amount of gas passes through the detection tube, the measured
gas in the gas sample is adsorbed on the surface of the indicator powder by
diffusion and chemically reacts with the color-generating chemical reagents to
cause the indicator powder to change color. The concentration of the measured
gas in the gas is different. The length of the color-changing column is also
different.
A.7.2 Reagents and materials
Ammonia detection tube: The volume fraction of the measuring range is 1×10-
6~30×10-6, or other suitable measuring ranges.
A.7.3 Analysis steps
The measurement starts when the nitrous oxide gas is injected into the
detection tube. The control of injection volume, injection flow and color change
are carried out in accordance with the operating instructions of the detection
tube. According to the length of the color change of the detection tube, the
ammonia content is obtained.
A.8 Determination of nitric oxide and nitrogen dioxide
A.8.1 Test tube method
A.8.1.1 Method principle
When a certain amount of gas passes through the detection tube, the measured
gas in the gas sample is adsorbed on the surface of the indicator powder by
diffusion and chemically reacts with the color-generating chemical reagents to
cause the indicator powder to change color. The concentration of the measured
gas in the gas is different. The length of the color-changing column is also
different.
A.8.1.2 Instruments and equipment
Nitrogen oxide detection tube: Volume fraction of the measuring range is
0.2×10-6~5×10-6, or other suitable measuring ranges.
A.8.1.3 Analysis steps
The measurement starts when the nitrous oxide gas is injected into the
detection tube. The control of injection volume, injection flow and color change
are carried out in accordance with the operating instructions of the detection
tube. According to the length of the color change of the detection tube, the total
...... Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Tips & Frequently Asked QuestionsQuestion 1: How long will the true-PDF of English version of GB 1886.350-2021 be delivered?Answer: The full copy PDF of English version of GB 1886.350-2021 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice. Question 2: Can I share the purchased PDF of GB 1886.350-2021_English with my colleagues?Answer: Yes. The purchased PDF of GB 1886.350-2021_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB 1886.350-2021 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.
How to buy and download a true PDF of English version of GB 1886.350-2021?A step-by-step guide to download PDF of GB 1886.350-2021_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD). Step 2: Search keyword "GB 1886.350-2021". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9
|