HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (30 Nov 2024)

FZ/T 60005-1991 PDF in English


FZ/T 60005-1991 (FZ/T60005-1991, FZT 60005-1991, FZT60005-1991)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
FZ/T 60005-1991English190 Add to Cart 0-9 seconds. Auto-delivery. Determination of breaking strength and elongation at break of nonwoven fabrics Obsolete
Standards related to (historical): FZ/T 60005-1991
PDF Preview

FZ/T 60005-1991: PDF in English (FZT 60005-1991)

FZ/T 60005-1991 FZ TEXTILE INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA FZ/T 60005-91 Determination of breaking strength and elongation at break of nonwoven fabrics APPROVED ON: JUNE 07, 1991 IMPLEMENTED ON: JANUARY 01, 1992 Issued by: Ministry of Textile Industry of PRC Table of Contents 1 Subject content and scope of application ... 3 2 Normative references ... 3 3 Principles ... 3 4 Instruments and appliances ... 3 5 Samples ... 4 6 Preparation of specimens ... 4 7 Humidity conditioning and standard atmosphere of specimen ... 4 8 Test steps ... 4 9 Calculation and presentation of results ... 5 10 Test report ... 5 Additional information ... 7 Determination of breaking strength and elongation at break of nonwoven fabrics This standard equivalently adopts international standard ISO 9703-3-1989 "Textiles - Test method of nonwoven fabrics - Part 3: Determination of tensile strength and elongation". 1 Subject content and scope of application This standard specifies the methods for the determination of breaking strength and elongation at break of nonwoven fabrics. This standard applies to all kinds of nonwoven fabrics. 2 Normative references GB 3923 Determination of breaking strength and elongation at break of woven fabrics (strip method) GB 6529 Standard atmosphere for humidity conditioning and testing of textiles GB 8170 Numerical rounding off rules 3 Principles For a specimen of specified size, stretch it along the length of the specimen until it breaks; record the breaking force and elongation at break. 4 Instruments and appliances 4.1 Tensile tester: Two types of tensile tester: CRT (constant velocity traction) or CRE (constant velocity extension), can be used. The tensile tester should meet the relevant requirements in GB 3923. When using a CRT type instrument, the use range shall be between 20% ~ 80% of the full scale. For referee tests or in case of disputes, the CRE type shall prevail. 4.2 For the wet test, there shall be equipment capable of immersing the specimen in water, as well as distilled water or deionized water. 4.3 Scissors and steel ruler. 5 Samples 5.1 Take specimens according to relevant product standards or agreements of relevant parties. OR cut 1 m sample for each type. 5.2 The sample is required to be representative, to ensure that the specimen taken has no obvious flaws, such as cracks and wrinkles, that affect the test results. 6 Preparation of specimens 6.1 Cut the specimen at least 100 mm away from the edge of the cloth, according to the parallel method specified in Appendix B of GB 3923. Use the trapezoidal method, to cut the specimen for the arbitration test. 6.2 Cut more than 5 specimens, each in the longitudinal direction (machine output direction) and transverse direction (cloth width direction) of the sample; make the length direction of the specimens parallel to the longitudinal direction (machine output direction) and transverse direction (cloth width direction). 6.3 The width of the specimen is 50 ± 0.5 mm. The length shall meet the nominal clamping distance of 200 mm. 7 Humidity conditioning and standard atmosphere of specimen 7.1 The pre-humidity conditioning of the specimens shall be carried out according to the provisions in Chapter 3 of GB 6529. The humidity conditioning shall be carried out, in accordance with Chapter 4 or equilibrated in the specified standard atmosphere for more than 24 hours. 7.2 The test is carried out in the standard atmosphere, which is stipulated in GB 6529; the arbitration test adopts the first-grade standard atmosphere. 7.3 If it is required to carry out the wet test, it is not necessary to carry out humidity conditioning; soak the specimen in the solution containing 1% wetting agent. 8 Test steps 8.1 Calibrate the zero position of the strength testing machine. 8.2 Adjust the nominal clamping distance of the strength testing machine to 200 ± 1 mm, the tensile speed to 100 ± 10 mm/min. ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.