FZ/T 50014-2008: Method for the determination of residual sulphur in viscose fibres - Direct iodimetry
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
FZ/T 50014-2008English70 Add to Cart 0-9 seconds. Auto-delivery Method for the determination of residual sulphur in viscose fibres - Direct iodimetry Valid

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: FZ/T 50014-2008
      

Similar standards

GB/T 43015   GB/T 39026   FZ/T 50010.13   

FZ/T 50014-2008: Method for the determination of residual sulphur in viscose fibres - Direct iodimetry


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/FZT50014-2008
FZ TEXTILE INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 59.060.01 W 50 Method for the determination of residual sulphur in viscose fibres - Direct iodimetry ISSUED ON: FEBRUARY 01, 2008 IMPLEMENTED ON: JULY 01, 2008 Issued by: National Development and Reform Commission of the People’s Republic of China

Table of Contents

Foreword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Terms and definitions ... 4 4 Principle ... 4 5 Reaction formula ... 5 6 Reagents and materials ... 5 7 Instruments ... 5 8 Sampling ... 6 9 Test environment ... 6 10 Analysis steps ... 6 11 Result calculation ... 7 12 Test report ... 8 Annex A (informative) Preparation of iodine standard titration solution ... 10 Method for the determination of residual sulphur in viscose fibres - Direct iodimetry

1 Scope

This Standard specifies the method for the determination of residual sulphur by redox-direct iodometry. This Standard is applicable to fibres made by viscose process.

2 Normative references

The following documents contain the provisions which, through reference in this Standard, become the provisions of this Standard. For dated references, their subsequent amendments (excluding corrigendum) or revisions do not apply to this Standard. However, the parties who enter into agreement based on this Standard are encouraged to investigate whether the latest versions of these documents are applicable. For undated reference documents, the latest versions apply to this Standard. GB/T 601 Chemical reagent - Preparations of standard volumetric solutions GB/T 4146 Textile terms and terminology (parts of chemical fibres) GB/T 8170 Rules for rounding off of numerical values GB/T 14334-2006 Sampling method for man-made staple fibres

3 Terms and definitions

For the purpose of this Standard, the terms and definitions specified in GB/T 4146 apply.

4 Principle

The sulphur attached to the viscose fibre reacts with sodium sulfite to produce sodium thiosulfate, which is titrated with iodine standard solution. The end point of the titration is judged according to the color change of the indicator. The residual sulphur content is calculated according to the volume consumed. 7.3 Measuring cylinder: the capacity is 200 mL. 7.4 Measuring cup: the capacity is 20 mL. 7.5 Volumetric flask: the capacity is 100 mL. 7.6 Pipette: the capacity is 50 mL. 7.7 Iodine flask: the capacity is 500 mL. 7.8 Ground spherical condenser tube. 7.9 Vacuum filtration device, including vacuum pump, suction filter flask, buffer flask, etc. 7.10 Buchner funnel. 7.11 Cooling device. 7.12 Heating device, ensuring constant temperature (100 °C) requirements. 7.13 Container, which can store samples, and the quality is known. 7.14 Thermometer, 0 ~ 100 °C, accuracy of 1 °C.

8 Sampling

- Unpackaged laboratory samples are taken out as needed; - Laboratory samples in batch samples are taken according to the provision of GB/T 14334-2006. Do not take out rolls that have been accidentally damp, scratched or of which the packaging has been opened during transportation.

9 Test environment

The test can be carried out in an environment with a temperature of 20 °C ± 5 °C, avoid sunlight indoors.

10 Analysis steps

10.1 Randomly TAKE about 20 g of sample, MIX them evenly and DIVIDE them into four parts, each of about 5 g, accurate to 0.001 g. Two of them are used for parallel test of residual sulphur content; the other two are used for moisture m2 - the mass of the sample and container after baking, in grams (g); mw - the mass of the sample before baking, in grams (g). It is calculated to three decimal places, and rounded off to two decimal places according to GB/T 8170. 11.2 Residual sulphur content of the sample It is calculated according to formula (2): where S - the residual sulphur content of the sample, in milligrams per 100 grams (mg/100 g); V1 - the volume of iodine standard titration solution consumed by the sample, in milliliters (mL); V0 - the volume of iodine standard titration solution in the blank test, in milliliters (mL); c - the concentration of iodine standard titration solution, in moles per liter (mol/L); M - the molar mass of sulphur, in grams per mole (g/mol) (M = 32.06); ms - the mass of the sample, in grams (g); W - the moisture content of the sample, %. The result is calculated and expressed to one decimal place. 11.3 Allowable error The moisture content test and the residual sulphur test shall have parallel tests, and the arithmetic mean of the two parallel test results shall be taken as the determination result. The relative error of the moisture content test shall not exceed 0.5 %; the relative error of the residual sulphur test shall not exceed 10 %.

12 Test report

a) sample name, source, batch number, etc.;

Annex A

(informative) Preparation of iodine standard titration solution A.1 Preparation of iodine standard titration solution [cቀ𝟏𝟐 𝐈𝟐ቁ = 0.05 mol/L] WEIGH 6.5 g of iodine and 17.5 g of potassium iodide; DISSOLVE in 100 mL of water; DILUTE to 1000 mL; SHAKE well; STORE in a brown bottle. A.2 Calibration of iodine standard titration solution [cቀ𝟏𝟐 𝐈𝟐ቁ = 0.05 mol/L] MEASURE 35.00 mL ~ 40.00 mL of the prepared iodine solution; PLACE in an iodine flask; ADD 150 mL of water (15 °C ~ 20 °C); TITRATE with sodium thiosulfate standard titration solution [c(Na2S2O3) = 0.05 mol/L]; ADD 2 mL of starch indicator (10 g/L) near the end point; continue to TITRATE until the blue color of the solution disappears. At the same time, carry out a blank test of iodine consumed by water: TAKE 250 mL of water (15 °C ~ 20 °C); ADD 0.05 mL ~ 0.20 mL of the prepared iodine solution and 2 mL of starch indicator (10 g/L); TITRATE with sodium thiosulfate standard titration solution [c(Na2S2O3) = 0.05 mol/L] until the blue color of the solution disappears. The concentration of iodine standard titration solution [cቀଵଶ Iଶቁ ] is calculated according to formula (A.1): where cቀଵଶ Iଶቁ - the concentration of iodine standard titration solution, in moles per liter (mol/L); V1 - the volume of sodium thiosulfate standard titration solution, in milliliters (mL); V2 - the volume of sodium thiosulfate standard titration solution for the blank test, in milliliters (mL); ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of FZ/T 50014-2008 be delivered?

Answer: The full copy PDF of English version of FZ/T 50014-2008 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of FZ/T 50014-2008_English with my colleagues?

Answer: Yes. The purchased PDF of FZ/T 50014-2008_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- FZ/T 50014-2008 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of FZ/T 50014-2008?

A step-by-step guide to download PDF of FZ/T 50014-2008_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "FZ/T 50014-2008".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9