HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB/T 6111-2018 (GB/T 6111-2003) PDF English

US$120.00 · In stock · Download in 9 seconds
GB/T 6111-2003: Thermoplastics pipes for the conveyance of fluids -- Resistance to internal pressure -- Test method
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Obsolete

GB/T 6111: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
GB/T 6111-2018English439 Add to Cart 4 days Thermoplastics piping systems for the conveyance of fluids -- Determination of the resistance to internal pressure Valid
GB/T 6111-2003English120 Add to Cart 0-9 seconds. Auto-delivery Thermoplastics pipes for the conveyance of fluids -- Resistance to internal pressure -- Test method Obsolete
GB/T 6111-1985English199 Add to Cart 2 days Standard test method for time-to-failure of thermoplastic pipe under constant internal pressure Obsolete

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: GB/T 6111-2003
      

Similar standards

GB/T 1601   GB/T 7193   GB/T 5451   GB/T 1600   

GB/T 6111-2003: Thermoplastics pipes for the conveyance of fluids -- Resistance to internal pressure -- Test method


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT6111-2003
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 23.040.20 G 33 Replacing GB/T 6111-1985 Thermoplastics pipes for the conveyance of fluids - Resistance to internal pressure - Test method (ISO 1167.1996, IDT) Issued on: MARCH 5, 2003 Implemented on: AUGUST 1, 2003 Issued by. General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China

Table of Contents

Foreword... 3 1 Scope... 4 2 Normative references... 4 3 Definitions... 4 4 Principle... 5 5 Test parameters... 5 6 Test apparatus... 5 7 Test pieces... 8 8 Calibration of the apparatus and calculation of the test pressure... 9 9 Conditioning... 9 10 Test procedure... 10 11 Test report... 11 Annex A (informative) Basic specifications... 13

Foreword

This Standard is identical to ISO 1167.1996 “Thermoplastics pipes for the conveyance of fluids - Resistance to internal pressure - Test method” (English version). The technical content is the same and the preparation method is identical, only editorial modifications in the text are made. This Standard replaces GB/T 6111-1985 “Standard test method for time-to-failure of thermoplastic pipe under constant internal pressure”. Compared with GB/T 6111-1985, this Standard has the following main changes. 1.CHANGE the standard name from the “Standard test method for time-to-failure of thermoplastic pipe under constant internal pressure” TO “Thermoplastics pipes for the conveyance of fluids - Resistance to internal pressure - Test method”. 2.ADD the clause of test parameters. 3.IMPROVE the accuracy requirements for test apparatus. 4.DELETE type C end caps; describe the other two types of end caps in detail. 5.CHANGE the number of test pieces to 3 and specify the length of test pieces. 6.SPECIFY the method and duration of conditioning of test pieces. 7.SPECIFY the treatment method for different test phenomenon during the test process. 8.ADD the informative Annex A. This Standard replaces GB/T 6111-1985 from the date of implementation. Annex A of this Standard is informative. This Standard is proposed by China Light Industry Federation. This Standard is under the jurisdiction of National Technical Committee on Plastics of Standardization Administration of China (TC 48). Drafting organizations of this Standard. Zhejiang Yonggao Plastic Industry Development Co., Ltd., Hebei Baoshuo Pipe Co., Ltd. Main drafters of this Standard. Huang Jian, Zhao Zhijie, Xu Xuecheng, Wang Shuhua, Jiao Cuiyun. Thermoplastics pipes for the conveyance of fluids - Resistance to internal pressure -Test method

1 Scope

This Standard specifies a method for determination of the resistance of thermoplastics pipes to constant internal water pressure at constant temperature. This Standard is applicable to thermoplastics pipes intended for the conveyance of fluids.

2 Normative references

The following standards contain provisions which, through reference in this text, constitute provisions of this Standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this Standard are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. GB/T 4117-2001 Thermoplastics pipes for the conveyance of fluids - Nominal outside diameters and nominal pressures (idt ISO 161-1.1996) GB/T 8806-1988 Method for dimension measuring of plastic pipes (eqv ISO 3126.1974) GB/T 18252-2000 Plastics piping and ducting systems - Determination of the long- term hydrostatic strength of thermoplastics materials in pipe form by extrapolation NOTE. GB/T 18252-2000 “Plastics piping and ducting systems - Determination of the long- term hydrostatic strength of thermoplastics materials in pipe form by extrapolation” is developed referring ISO/DIS 9080.1997 “Thermoplastics pipes for the transport of fluids - Methods of extrapolation of hydrostatic stress rupture data to determine the long-term hydrostatic strength of thermoplastics pipe materials”, so the technical content of this standard is identical to ISO/DIS 9080.1997.ISO/DIS 9080.1997 is the revision to ISO/TR 9080.

3 Definitions

For the purposes of this Standard, the definitions given in GB/T 4217-2001 apply.

4 Principle

After conditioning, test pieces are subjected to a specified constant internal hydrostatic pressure to a specified period of time or until failure. Throughout the test, the test pieces are kept in an environment at a specified constant temperature. this is water (“water-in-water” test), another liquid (“water-in-liquid” test) or air (“water-in-air” test).

5 Test parameters

The following test parameters are set by the standard making reference to this Standard. a) the type of end cap to be used (see 6.1); b) the size and S-series of pipe to be used (see 7.1); c) the test temperature (see 6.2 and 10.1); d) for pipes of nominal outside diameter dn greater than 315 mm, the free length of the test piece, if other than 1 000 mm (see 7.1.1); e) the number of test pieces (see 7.2); f) the test pressure p or the hoop stress σ to be induced by the test pressure (see 8.2.2); g) the conditioning period (see clause 9), if other than as specified in table 1; h) the type of test, i.e. water-in-water/air/liquid (see clause 4 and 10.1); i) the duration of the test under pressure and the criteria for a failure (see 10.3); j) the requirements for additional testing.

6 Test apparatus

6.1 End caps End caps are fitted on two ends of the test pieces. By means of an appropriate system, end caps shall allow sealing and connection to the pressurizing equipment. The end cap shall be of one of the following types. Type A. Fittings rigidly connected to the test piece but not to each other, and hence Capable of checking conformity to the specified test pressure. In the case of gauges or similar calibrated pressure measurement devices, the range of the gauge shall be such that the required pressure setting lies within the calibrated range of the device used. The pressure measurement devices shall not contaminate the test fluid. The use of master gauges for calibration of the apparatus is recommended. 6.6 Thermometer or equivalent Capable of checking conformity to the specified test temperature. 6.7 Timer Timer shall capable of recording the duration of the pressure applications up to the moment of failure or leakage. NOTE. It is recommended that equipment be used which is sensitive to pressure variations due to leaks or a failure and which is capable of stopping the timer and, if necessary, closing the pressure circuit for the test piece concerned. 6.8 Means of measuring the wall thickness Conforming to GB/T 8806-1988. NOTE. A calibrated ultrasonic measuring device can be used. 6.9 Means of measuring the mean outside diameter of the pipe Conforming to GB/T 8806-1988, e.g. a metal tape.

7 Test pieces

7.1 Dimensions 7.1.1 Free length The free length L0 (as shown in Figure 1) of each test piece between the end caps shall be at least three times the outside diameter for pipes with a nominal outside diameter dn less than or equal to 315 mm, with a minimum of 250 mm. For pipes with a nominal outside diameter dn greater than 315 mm, a minimum free length L0 of greater than or equal to 1 000 mm shall be used. 7.1.2 Total length For type B end caps, the total length of the test piece shall be such that the test piece NOTE. Failure is “brittle” if no plastic deformation has occurred in the failure zone. If the failure is accompanied by plastic deformation in the failure zone, visible without magnification, it is of the “ductile” type. In the event of equipment failure, tests which have been under way for more than 1 000 h can be continued providing the equipment is reinstated within 3 days. For tests which have been under way for more than 5 000 h, the test can be continued providing the equipment is reinstated within 5 days. Following equipment failure, if the test pieces are closed off at the test pressure by a solenoid valve or other means the test can be continued in the event of periods of breakdown in excess of that stated above. It should be noted that, in this situation, the pressure will gradually decrease due to continuing Creep in the test piece. The time whilst the equipment is not able to function normally shall not be included in the test time. 10.4 If a break occurs in the test piece at a distance of less than 0.1 L0 from an end cap, disregard the result and repeat the test using another test piece (L0 is the... ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.