GB/T 18216.9-2015 English PDFUS$454.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 18216.9-2015: Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. --Equipment for testing, measuring or monitoring of protective measures -- Part 9: Equipment for insulation fault location in IT systems Status: Valid
Basic dataStandard ID: GB/T 18216.9-2015 (GB/T18216.9-2015)Description (Translated English): Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. --Equipment for testing, measuring or monitoring of protective measures -- Part 9: Equipment for insulation fault location in IT systems Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: N20 Classification of International Standard: 17.220.20 Word Count Estimation: 23,260 Date of Issue: 2015-12-10 Date of Implementation: 2016-07-01 Quoted Standard: GB 16895.21-2011; GB/T 16935.1-2008; GB/T 16935.3-2005; GB/T 4798.1-2005; GB/T 4798.2-2008; GB/T 4798.3-2007; GB 4793.1-2007; GB/T 18268.24- 2010; GB/T 18216.1-2012; GB/T 18216.8-2015 Adopted Standard: IEC 61557-9-2009, IDT Regulation (derived from): National Standard Announcement 2015 No.38 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies requirements for insulation fault location system, insulation fault location system for ungrounded AC IT systems, there are electrically connected to the DC circuit and a nominal voltage not exceeding 1 000 V ac ungrounded AC IT systems, as well as the DC voltage is less than 1 500 V insulation fault ungrounded DC IT systems to locate any part, regardless of the measurement principle. GB/T 18216.9-2015: Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. --Equipment for testing, measuring or monitoring of protective measures -- Part 9: Equipment for insulation fault location in IT systems---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Electrical safty in low voltage distribution systems up to 1 000 V acand 1 500 V dc - Equipment for testing, measuring or monitoring of protective measures - Part 9. Equipment for insulation fault location in IT systems ICS 17.220.20 N20 National Standards of People's Republic of China AC 1000V and 1500V dc Electrical safety in low voltage distribution systems protective measures Testing, measuring or monitoring equipment - Part 9. IT system insulation fault locating device 1500Vd.c.-Equipmentfortesting, measuringormonitoringofprotective measures-Part 9. EquipmentforinsulationfaultlocationinITsystems (IEC 61557-9.2009, IDT) Issued on. 2016-07-01 2015-12-10 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsIntroduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 Requirement 3 4 5 signs and instructions 5 6 Test 6 Appendix A (normative) in health facilities in the insulation fault location device 9 Appendix B (normative) Portable insulation fault locating device 12 Example upstream and Annex C (informative) Insulation fault location system/downstream leakage capacitance instructions 14 References 16ForewordGB/T 18216 "AC 1000V and 1500V DC low voltage distribution systems for electrical safety protection measures for testing, measuring or Monitoring equipment "is divided into 13 parts. --- Part 1. General requirements; --- Part 2. Insulation resistance; --- Part 3. Loop impedance; --- Part 4. equipotential grounding resistance and grounding resistance; --- Part 5. Resistance to ground; --- Part 6. TT and TN systems a residual current protective device (RCD); --- Part 7. Phase sequence; Part --- Article 8. IT system insulation monitoring device; --- Part 9. IT system insulation fault location equipment; --- Part 10. Integrated device detecting or monitoring protective measures; --- Part 11. Effectiveness Class A and Class B residual current monitoring in TT, TN, IT system; --- Part 12. Performance measuring and monitoring devices (PMD); --- Part 13. power distribution system for leakage current measurement handheld current clamps and sensors. This section GB/T Part of 918,216. This section drafted in accordance with GB/T 1.1-2009 given rules. This section uses the translation method is equivalent to using IEC 61557-9.2009 "AC 1000V and 1500V DC low voltage distribution systems Electrical security measures for testing, measuring or monitoring equipment - Part 9. IT system insulation fault location device "(in English). Consistency correspondence between this part of international documents and normative references of our files are as follows. --- GB 4793.1-2007 measurement, control and laboratory safety requirements for electrical equipment - Part 1. General requirements (IEC 61010-1.2001, IDT) --- GB/T 4798.1-2005 application of electric and electronic products environmental conditions of the first portion of the reservoir (IEC 60721-3-1.1997, MOD) --- GB/T 4798.2-2008 application of electric and electronic products environmental conditions - Part 2. Transport (IEC 60721-3-2.1997, MOD) --- GB/T 4798.3-2007 application of electric and electronic products environmental conditions - Part 3. Stationary use at weather protected locations (IEC 60721-3-3.2002, MOD) --- GB 16895.21-2011 low-voltage electrical installations - Part 4-41. Protection for safety Protection against electric shock (IEC 60364-4-41. 2005, IDT) --- Insulation coordination GB/T 16935.1-2008 within the low-pressure system equipment - Part 1. Principles, requirements and tests (IEC 60664-1.2007, IDT) --- GB/T 16935.3-2005 within low-voltage systems Insulation coordination for equipment - Part 3. Using the coating, potting or molding for Protection against pollution (IEC 60664-3.2003, IDT) --- GB/T 18216.1-2012 AC 1000V and 1500V DC low voltage distribution systems electrical safety precautions Testing, measuring or monitoring equipment - Part 1. General requirements (IEC 61557-1.2007, IDT) --- GB/T 18216.8-2015 AC 1000V and 1500V DC low voltage distribution systems electrical safety precautions Testing, measuring or monitoring equipment - Part 8. IT system insulation monitoring devices (IEC 61557-8.2007, IDT) --- GB/T 18268.24-2010 measurement, control and laboratory use EMC requirements for electrical equipment Part 24. Special Specific requirements in line with the insulation monitoring device and comply with the IEC 61557-8 test IEC 61557-9 Insulation fault location devices of Configuration, operating conditions and performance criteria (IEC 61326-2-4.2006, IDT). This part made the following editorial changes. --- With GB/T 18216 in this section instead of IEC 61557-9.2009; --- Decimal symbol with "." Instead of "." Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents. This part is proposed by China Machinery Industry Federation. This part of the National Electrical Instrument Standardization Technical Committee (SAC/TC104) centralized. This section is drafted. Shanghai Instrument Research Institute, Dongtou sea-Electric Co., Ltd., Shanghai Industrial Technology Research Institute, Shanghai Grand Science, Hangzhou BH Electric Co., Ltd., Suzhou Electronic Instrument Co., Ltd. Ming Wei. The main drafters of this section. Tenghua Qiang, Shen Qian, Ye Yongkang, Zhangyin Fu, keen fees, Ding Zhigang, Wang Weiqi, Xu Mingjie, Dong Yafeng, Sun Jun Yan, Ye Paradise, Houdian Cheng. AC 1000V and 1500V dc Electrical safety in low voltage distribution systems protective measures Testing, measuring or monitoring equipment - Part 9. IT system insulation fault locating device1 ScopeGB/T 18216 in this section specifies the requirements for insulation fault location system, insulation fault location system for ungrounded AC IT system EC, there is electrically connected to the DC circuit and a nominal voltage not exceeding 1000V AC ungrounded AC IT systems, as well as the DC voltage is less than 1500V insulation fault ungrounded DC IT systems to locate any part, regardless of the measurement principle. Note 1. IT systems to elaborate IEC 60364-4-41 (including other documents) in. Additional information for selecting the monitoring device should be in other standards Noted. Note 2. You can find more information on insulation fault location in the following standards. IEC 60364-4-41.2005 of 411.6, and the IEC 60364-5-53. 2001 531.3.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. IEC 60364-4-41.2005 low-voltage electrical installations Part 4-41. Protection for safety Protection against electric shock (Low-voltageelectrical instalations-Part 4-41. Protectionforsafety-Protectionagainstelectricshock) IEC 60664-1 within low-voltage systems with insulated equipment - Part 1. Principles, requirements and tests (Insulationcoordination forequipmentwithinlow-voltagesystems-Part 1. Principles, requirementsandtests) A low pressure system in the IEC 60664-3 Insulation coordination for equipment - Part 3. antipollution with potting or die coating use (Insulationcoordinationforequipmentwithinlow-voltagesystems-Part 3. Useofcoating, potting ormouldingforprotectionagainstpolution) IEC 60721-3-1 Classification of environmental conditions - Part 3. Environmental parameters and their severities grouping Section 1. Storage (Clas- sificationofenvironmentalconditions-Part 3. Classificationofgroupsofenvironmentalparameters andtheirseverities-Section1. Storage) IEC 60721-3-2 Classification of environmental conditions - Part 3. Environmental parameters and their severities Section 2 groups. Transport (Clas- sificationofenvironmentalconditions-Part 3. Classificationofgroupsofenvironmentalparameters andtheirseverities-Section2. Transportation) IEC 60721-3-3 Classification of environmental conditions - Part 3. Environmental parameters and their severities packet of the first three. in weatherproof Influence fixed place of use (Classificationofenvironmentalconditions-Part 3. Classificationofgroupsof environmentalparametersandtheirseverities-Section3. Stationaryuseatweatherprotectedloca- tions) IEC 61010-1.2001 measurement, control and laboratory use Part 1 Safety requirements for electrical equipment. General requirements (Safetyre- quirementsforelectricalequipmentformeasurement, control, andlaboratoryuse-Part 1. General requirements) EMC IEC 61326-2-4 Electrical equipment for measurement, control and laboratory use requirements Part 2-4. Particular requirements apply by ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 18216.9-2015_English be delivered?Answer: Upon your order, we will start to translate GB/T 18216.9-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 18216.9-2015_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 18216.9-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |