GB/T 17215.321-2021 PDF EnglishUS$290.00 · In stock · Download in 9 seconds
GB/T 17215.321-2021: Electricity metering equipment (AC) - Particular requirements - Part 21: Static meters for active energy(classes A, B, C, D and E) Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid GB/T 17215.321: Historical versions
Similar standardsGB/T 17215.321-2021: Electricity metering equipment (AC) - Particular requirements - Part 21: Static meters for active energy(classes A, B, C, D and E)---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT17215.321-2021 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 17.220.20 N 22 Replacing GB/T 17215.321-2008, GB/T 17215.322-2008 Electricity metering equipment (AC) - Particular requirements - Part 21: Static meters for active energy (classes A, B, C, D and E) ISSUED ON: APRIL 30, 2021 IMPLEMENTED ON: NOVEMBER 01, 2021 Issued by: State Administration for Market Regulation; Standardization Administration of PRC. Table of ContentsForeword ... 4 Introduction ... 8 1 Scope ... 10 2 Normative references ... 12 3 Terms and definitions... 12 4 Standard electricity value ... 13 4.1 Voltage ... 13 4.2 Current ... 13 4.3 Frequency ... 13 4.4 Power consumption ... 14 5 Structure ... 14 5.1 General requirements ... 14 5.2 Mechanical test ... 14 5.3 Windows ... 14 5.4 Sealing requirements ... 14 5.5 Display of measured value ... 14 5.6 Storage of measured values ... 14 5.7 Output ... 15 5.8 Electrical pulse input ... 15 5.9 Working indicator ... 15 5.10 Protection against mechanical hazards ... 15 5.11 Measures to protect the connection ... 15 5.12 Prevention of flame spreading ... 15 5.13 Meter temperature limit and heat resistance ... 15 6 Marking and documentation of the meter ... 16 7 Metering performance ... 16 7.1 General test conditions ... 16 7.2 Methods of accuracy verification ... 16 7.3 Meter constant test ... 17 7.4 No-load condition (creeping) test ... 17 7.5 Starting current test ... 17 7.6 Basic maximum allowable error ... 17 7.7 Repeatability test ... 18 7.8 Variation requirement test ... 18 7.9 Variation test of load current rise and fall ... 19 7.10 Error consistency test ... 19 7.11 Error limit test due to influence quantity ... 19 7.12 Combined error test of electric energy indication ... 23 7.13 Timing accuracy test ... 23 7.14 Combined maximum allowable error test ... 23 8 Climatic environment ... 23 9 External influences ... 23 10 Metering performance protection ... 23 11 Electrical ... 24 11.1 Clearance and creepage distances ... 24 11.2 Electrical test procedure ... 24 11.3 Tests for voltage circuits ... 25 11.4 Dielectric strength test ... 25 11.5 Short-time overcurrent test ... 25 12 Type test ... 25 Appendix A (Normative) Safety-related electrical test procedures ... 26 References ... 27 Electricity metering equipment (AC) - Particular requirements - Part 21: Static meters for active energy (classes A, B, C, D and E)1 ScopeThis Part of GB/T 17215.3 specifies the standard electricity value, structure, meter's marking and documentation, metering performance, climate environment, external influence, metering performance protection, electrical requirements, for static meters for active energy. This Part of GB/T 17215.3 is only applicable to the newly manufactured static meters for active energy, which is used to measure the AC active energy, in 50 Hz or 60 Hz power grid, AND has an accuracy class of A, B, C, D, E. (below referred to as "meter"). It is also applicable to other type tests. Note 1: For other requirements (such as structure, EMC, reliability), refer to GB/T 17215.211- 2021, as well as the relevant parts of GB/T 17215.911, GB/T 17215.921, GB/T 17215.9311, GB/T 17215.9321, GB/T 17215.941. This Part applies to newly manufactured electricity metering equipment, which is used to meter and control electrical energy in the power grid, that has a voltage not exceeding 600 V. All special functional units, except the electrical energy measuring function, can be integrated in the meter enclosure, OR can form a separate enclosure. Note 2: The above voltage is the line-to-neutral line voltage, which is derived from the nominal voltage, as shown in Table 7 of IEC 62052-31:2015. If the meter has functions other than metering active energy, for example: - Measurement of voltage amplitude, current amplitude, power, frequency, power factor, etc.; - Measurement of power quality parameters; - Load control function; - Data communication interface. If encapsulated in the meter enclosure, the relevant standards can apply to these functional requirements. However, the requirements for these functions are not within the scope of this Part. Note 3: The requirements for power monitoring devices and measurement functions (such as voltage amplitude, current amplitude, power, frequency, etc.) have been covered in GB/T 18216.12; BUT equipment, that complies with GB/T 18216.12, is not suitable as a payment meter, unless they also meet the accuracy class requirements of this Part. Note 4: The requirements for power quality monitoring meters have been covered in IEC 62586-1. The measurement methods for power quality monitoring functions have been covered in GB/T 17626.30-2012. The test requirements for power quality monitoring functions are covered in IEC 62586-2. The requirements of this Part apply, if the meter is designed to be mounted on a specified mating (meter) socket or rack. The test is performed, with the meter mounted on the specified mating socket or rack. However, the requirements for such socket or rack are outside the scope of this Part. Note 5: Examples of rack-mounted meters are: rail-mounted meters, panel-mounted meters, etc. If the meter is designed to install a separated indicator display, the requirements of this Part apply; meanwhile, the meter can be connected to its separated indicator display for testing, unless otherwise specified. If the meter has more than one current circuit per phase (for example: multi-unit meter), the requirements of this Part apply to all current circuits of any current-measuring unit, in the meter enclosure. This Part also applies to auxiliary input and output circuits, operating indicators, test outputs of electricity metering equipment. Note 6: For example, pulse input and output, control input and output, power test output. This Part distinguishes: - Single-phase meters and multi-phase meters; - Directly connected meters and meters connected via a transformer; - Meters with integrated indicating displays and meters with separated indicating displays; - Indoor and outdoor meters. This Part does not apply to: - The meters, which have a line-to-neutral voltage in excess of 600 V derived from the nominal voltage; 4.4 Power consumption Power consumption shall comply with the requirements, test conditions, test procedures, acceptance criteria, which are specified in 4.4 of GB/T 17215.211-2021.5 Structure5.1 General requirements The general requirements of the structure shall comply with the provisions in 5.1 of GB/T 17215.211-2021. 5.2 Mechanical test The mechanical test shall comply with the provisions of 5.2 in GB/T 17215.211-2021. It shall also comply with the spring hammer test requirements, test conditions, test procedures, acceptance criteria, which are specified in 8.2 of IEC 62052-31:2015. 5.3 Windows The window requirements shall comply with the provisions in 5.3 of GB/T 17215.211- 2021. 5.4 Sealing requirements The requirements for sealing shall comply with the provisions in 5.4 of GB/T 17215.211-2021. 5.5 Display of measured value The measurement value display requirements shall comply with the provisions of 5.5 in GB/T 17215.211-2021. 5.6 Storage of measured values The storage requirements of the measured values shall comply with the provisions in 5.6 of GB/T 17215.211-2021. 5.7 Output The output requirements shall comply with the provisions of 5.7 in GB/T 17215.211- 2021. 5.8 Electrical pulse input The electrical pulse input requirements shall comply with the provisions in 5.8 of GB/T 17215.211-2021. 5.9 Working indicator The working indicator requirements shall comply with the provisions of 5.9 in GB/T 17215.211-2021. 5.10 Protection against mechanical hazards The meter shall not produce mechanical hazards, under normal working conditions. The protection test for mechanical hazards shall be carried out, in accordance with 7.2 of IEC 62052-31:2015. 5.11 Measures to protect the connection The requirements for the protective earth terminal shall comply with the provisions of 6.5.2.3 in IEC 62052-31:2015. The requirements for the protective connection impedance of the permanently connected equipment shall comply with the provisions in 6.5.2.4 of IEC 62052-31:2015. Note: Class I protective equipment requires a protective earth terminal. 5.12 Prevention of flame spreading The flame spreading prevention shall comply with the provisions of 9.3.2.1 of IEC 62052-31:2015. 5.13 Meter temperature limit and heat resistance 5.13.1 Surface temperature limits to prevent burns When the ambient temperature is 40 °C, the temperature of the easy-to-contact surface of the meter shall not exceed the value given in 1) in Table 31 of IEC 62052-31:2015, under normal conditions. When the ambient temperature exceeds 40 °C, the temperature of the easily accessible surface of the meter is allowed to exceed the value, which is given in 1) in Table 31 of IEC 62052-31:2015, BUT the excess value shall not be greater than the difference, between the ambient temperature and 40 °C. The surface of the terminal box, which is covered by the terminal cover, OR the surface of the board-mounted meter, which is protected by the fence, is not regarded as an accessible surface. The test method shall comply with the provisions in 10.4 of IEC 62052-31:2015. 5.13.2 Temperature limits for terminals When the ambient temperature is 40 °C, the temperature of the terminal shall not exceed the value, which is given in Table 32 of IEC 62052-31:2015, under normal conditions. When the ambient temperature exceeds 40 °C, the temperature of the terminal is allowed to exceed the value, which is given in Table 32 of IEC 62052-31:2015, BUT the excess value shall not be greater than the difference, between the ambient temperature and 40 °C. The test method shall comply with the provisions in 10.4 of IEC 62052-31:2015.6 Marking and documentation of the meterThe marking and documents of the meter shall comply with the provisions of Chapter 6 in GB/T 17215.211-2021.7 Metering performance7.1 General test conditions The general test conditions shall comply with the provisions in 7.1 of GB/T 17215.211- 2021. 7.2 Methods of accuracy verification The method of accuracy verification shall comply with the provisions in 7.2 of GB/T 17215.211-2021. 11.3 Tests for voltage circuits 11.3.1 Withstand long-term overvoltage test The withstand long-term overvoltage test shall comply with the provisions of 6.10.3.2 in IEC 62052-31:2015. 11.3.2 Surge test The surge test shall comply with the provisions of 9.3.9 in GB/T 17215.211-2021. 11.4 Dielectric strength test 11.4.1 Humidity conditioning The humidity conditioning test shall comply with the provisions in 6.10.4.2 of IEC 62052-31:2015. 11.4.2 Test method and test equipment preparation The dielectric strength test shall comply with the requirements of 6.10.4.3.1 in IEC 62052-31:2015. The preparation of the test equipment shall comply with the requirements in 6.10.4.3.2 of IEC 62052-31:2015. 11.4.3 Impulse voltage test The impulse voltage test shall comply with the provisions of 6.10.4.3.3 in IEC 62052- 31:2015. The test voltage shall comply with the provisions in Table 7 of IEC 62052- 31:2015. 11.4.4 AC power frequency voltage test The AC power frequency voltage test shall comply with the provisions of 6.10.4.3.4 in IEC 62052-31:2015. The test voltage shall comply with the provisions in Table 11 in IEC 62052-31:2015. 11.5 Short-time overcurrent test The short-time overcurrent test shall comply with the provisions of 9.4.11 in GB/T 17215.211-2021.12 Type testThe type test shall comply with the provisions of Chapter 11 of GB/T 17215.211-2021. ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of GB/T 17215.321-2021 be delivered?Answer: The full copy PDF of English version of GB/T 17215.321-2021 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB/T 17215.321-2021_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 17215.321-2021_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 17215.321-2021 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.Question 5: Should I purchase the latest version GB/T 17215.321-2021?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 17215.321-2021 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.How to buy and download a true PDF of English version of GB/T 17215.321-2021?A step-by-step guide to download PDF of GB/T 17215.321-2021_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB/T 17215.321-2021". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |