GB/T 18216.3-2021 English PDF

US$184.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 18216.3-2021: Electrical safety in low voltage distribution systems up to 1 000 V a. c. and 1 500 V d. c. - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance
Status: Valid

GB/T 18216.3: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 18216.3-2021184 Add to Cart 3 days Electrical safety in low voltage distribution systems up to 1 000 V a. c. and 1 500 V d. c. - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance Valid
GB/T 18216.3-2012359 Add to Cart 3 days Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. -- Equipment for testing, measuring or monitoring of protective measures -- Part 3: Loop impedance Obsolete
GB/T 18216.3-2007279 Add to Cart 3 days 1000V AC and 1500V dc low voltage distribution system electrical safety measures for testing, measuring or monitoring equipment -- Part 3: Loop impedance Obsolete

Similar standards

GB 4793   GB/T 15284   GB/T 17215.321   GB/T 18216.12   GB/T 18216.7   GB/T 18216.11   

Basic data

Standard ID: GB/T 18216.3-2021 (GB/T18216.3-2021)
Description (Translated English): Electrical safety in low voltage distribution systems up to 1 000 V a. c. and 1 500 V d. c. - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: N20
Word Count Estimation: 10,183
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration

GB/T 18216.3-2021: Electrical safety in low voltage distribution systems up to 1 000 V a. c. and 1 500 V d. c. - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Electrical safety in low voltage distribution systems up to 1 000 V acand 1 500 V dc- Equipment for testing, measuring or monitoring of protective measures-Part 3.Loop impedance ICS 17.220.20 CCSN20 National Standards of People's Republic of China Replace GB/T 18216.3-2012 AC 1000V and DC 1500V and below Testing of electrical safety protection measures for low-voltage power distribution systems, Measuring or monitoring equipment Part 3.Loop impedance (IEC 61557-3.2019, IDT) Released on 2021-05-21 and implemented on 2021-12-01 State Administration of Market Supervision and Administration Issued by the National Standardization Management Committee

Table of contents

Foreword Ⅰ Introduction Ⅱ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 Requirements 2 4.1 Overview 2 4.2 Measurement of loop impedance 2 4.3 External resistance 2 4.4 Fault voltage exceeding UL 2 4.5 Overvoltage 2 5 Logo and instruction manual 3 5.1 Logo 3 5.2 Instruction Manual 3 6 Test 3 6.1 Overview 3 6.2 Work uncertainty 3 6.3 External resistance 5 6.4 Fault voltage 5 6.5 Overvoltage 5 Reference 6

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules of Standardization Documents" Drafting. This document is GB/T 18216 "AC 1000V and DC 1500V and below low-voltage power distribution system electrical safety protection measures Part 3 of "Testing, Measuring or Monitoring Equipment". GB/T 18216 has released the following parts. ---Part 1.General requirements; ---Part 2.Insulation resistance; ---Part 3.Loop impedance; ---Part 4.Grounding resistance and equipotential grounding resistance; ---Part 5.Resistance to ground; ---Part 8.Insulation monitoring device in IT system; ---Part 9.Insulation fault location equipment in IT systems; ---Part 12.Performance Measurement and Monitoring Device (PMD). This document replaces GB/T 18216.3-2012 "Electrical safety protection for low-voltage power distribution systems below 1000V AC and 1500V DC Test, measurement or monitoring equipment for protective measures Part 3.Loop impedance", compared with GB/T 18216.3-2012, except for structural adjustments and In addition to editorial changes, the main technical changes are as follows. ---Added requirements for measurement categories (see 4.1); ---Added new requirements for the instruction manual (see 5.2). The translation method used in this document is equivalent to IEC 61557-3.2019 ``AC 1000V and DC 1500V and below low-voltage power distribution system Testing, measuring or monitoring equipment for integrated electrical safety protection measures. Part 3.Loop impedance. Please note that some of the contents of this document may involve patents. The issuing agency of this document is not responsible for identifying patents. This document was proposed by China Machinery Industry Federation. This document is under the jurisdiction of the National Electrical Instrumentation Standardization Technical Committee (SAC/TC104). Drafting organizations of this document. Harbin Institute of Electrical Engineering and Instrumentation Co., Ltd., State Grid Heilongjiang Electric Power Co., Ltd. Electric Power Research Institute, State Grid Chongqing Electric Power Company Marketing Service Center, State Grid Hebei Electric Power Co., Ltd. Xiong’an New District Power Supply Company, Xiamen Yesheng Electric Co., Ltd. Company, State Grid Jiangsu Electric Power Co., Ltd. Marketing Service Center, Yunnan Power Grid Co., Ltd. Metering Center, Yantai Oriental Weston Electric Co., Ltd. Co., Ltd., Heilongjiang Province Electrical Instrumentation Engineering Technology Research Center Co., Ltd., Zhejiang Chentai Technology Co., Ltd., State Grid Jiangsu Province Electric Power Co., Ltd., Ningbo Canaan Intelligent Electric Co., Ltd., State Grid Henan Electric Power Company Electric Power Research Institute, State Grid Tianjin Municipal Power Power Company Electric Power Research Institute, Xuji Group Co., Ltd., State Grid Jibei Electric Power Co., Ltd. Measurement Center, Shenzhen Xinglong Technology Co., Ltd. Co., Ltd., Holley Technology Co., Ltd., Beijing Zhongchen Hongchang Technology Co., Ltd. The main drafters of this document. Jiang Bin, Chen Wenxin, Sheng Yuhe, Wang Sanqiang, Li Ji, Liu Haifeng, Shen Xin, Cong Peijian, Chen Xiaoguang, Bao Jin, Zhao Bin, Huang Jianzhong, Wang Sen, Ouyang Zengkai, Li Wei, Guo Chuang, Ye Hongen, Jiang Weiping, Luo Yurong, Zeng Shitu, Yi Zhonglin, Qin Guoxin, Zhao Wei, Li Guilin. The release status of this document and the previous versions of the standard replaced are as follows. --- First published in.2007 as GB/T 18216.3-2007, first revised in.2012; ---This is the second revision.

Introduction

IEC 60364-6 specifies the first test, continuous monitoring and adjustment of these equipment in TN, TT or IT systems. Standardized conditions for the post-adjustment test. In addition to the general standards that specify the implementation of these tests, IEC 60364-6 also includes To verify the requirements. Only in a few cases, such as when measuring insulation resistance, does IEC 60364-6 include the measuring device used. Details of the characteristics of the settings. Circuit diagrams given as examples in IEC 60364-6 and cited in the main text of the document are generally not applicable actual use. When dangerous voltages appear in the electrical installation and the equipment is improperly used or defective, the implementation of the test in the electrical installation can easily cause concern. outer. Therefore, in addition to simplifying the measurement, technicians also need to rely on measurement devices that ensure the safety of the measurement method. The application of the general safety rules for electrical and electronic measuring devices (IEC 61010-1) for protective measures is in itself insufficient. in Measurements in power installations are not only harmful to technicians, but also to third parties due to different measurement methods. Similarly, in order to obtain an objective judgment about the equipment, such as periodic tests, continuous insulation monitoring, or In the case of performance assurance, an important prerequisite is to use measurement devices from different manufacturers to obtain reliable and comparable measurement results. The purpose of GB/T 18216 is to specify uniform principles that are consistent with the above characteristics. These principles are applicable to nominal voltage AC Measuring and monitoring equipment for electrical safety test and performance test in 1000V and DC 1500V and below systems. GB/T 18216 It is proposed to consist of ten parts. ---Part 1.General requirements. The purpose is to establish a low-voltage power distribution system with nominal voltages of AC 1000V and DC 1500V and below General requirements for test equipment used for electrical safety measurement and monitoring in the system. ---Part 2.Insulation resistance. The purpose is to establish that the measurement is suitable for the insulation of equipment and electrical installation equipment in a non-excited state Relevant requirements for resistance equipment. ---Part 3.Loop impedance. The purpose is to establish between the measuring line conductor and the protective conductor, between the line conductor and the neutral conductor, or between the two conductors. The relevant requirements of the loop impedance device between the line conductors. ---Part 4.Grounding resistance and equipotential grounding resistance. The purpose is to establish the grounding conductor, protective grounding conductor and And the relevant technical requirements for the resistance of the equipotential bonding conductor. ---Part 5.Resistance to ground. The purpose is to establish requirements for measuring equipment that uses AC voltage to measure resistance to earth. ---Part 6.Effectiveness of Residual Current Device (RCD) in TT, TN and IT systems. The purpose is to establish that the measurement is suitable for Relevant requirements for test equipment for the effectiveness of protective measures for residual current devices in TT, TN and IT systems. ---Part 8.Insulation monitoring device in IT system. The purpose is to establish relevant requirements for insulation monitoring devices in IT systems. ---Part 9.Insulation fault location equipment in IT systems. The purpose is to establish the phase of insulation fault location equipment in the IT system. Close requirements. --- Part 10.Combination measuring equipment for testing, measuring or monitoring protective measures. The purpose is to establish test, measurement or monitoring The related requirements of the equipment in which a variety of measurement functions or measurement methods are combined together. ---Part 12.Performance Measurement and Monitoring Device (PMD). The purpose is to establish a comprehensive measurement and monitoring of electrical parameters in the distribution system. Meet the relevant requirements of performance measurement and monitoring devices. AC 1000V and DC 1500V and below Testing of electrical safety protection measures for low-voltage power distribution systems, Measuring or monitoring equipment Part 3.Loop impedance

1 Scope

This document specifies the loop impedance setting between the measuring line conductor and the protective conductor, between the line conductor and the neutral conductor, or between the two conductors. According to the requirements of equipment, the measurement of loop impedance is carried out by the method of loading the test line to measure the voltage drop.

2 Normative references

The contents of the following documents constitute the indispensable clauses of this document through normative references in the text. Among them, dated quotations Only the version corresponding to that date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to This document. GB/T 18216.1-2021 AC 1000V and DC 1500V and below low-voltage power distribution system electrical safety protection measures Testing, measuring or monitoring equipment Part 1.General requirements (IEC 61557-1.2019, IDT) IEC 61010-1.2010 AMD1.2016 Safety requirements for electrical equipment for measurement, control and laboratory use Part 1.General Requirements (Safetyrequirementsforelectricalequipmentformeasurement, controlandlaboratoryuse-Part 1.Generalrequirements) IEC 61010-2-030.2017 Safety requirements for electrical equipment for measurement, control and laboratory use Part 2-030.with test and Special requirements for equipment measuring circuits (Safety requirements for electrical equipment for measurement, control, andlaboratoryuse-Part 2-030.Particularrequirementsforequipmenthavingtestingormeasuring circuits)

3 Terms and definitions

The following terms and definitions defined in GB/T 18216.1-2021 apply to this document. ISO and IEC maintain a terminology database for standardization. The website is as follows. 3.1 Loading A method of applying a load to a circuit in a power distribution system to cause a voltage drop. 3.2 Loadingequipment A part of a measuring device that is used to load the circuit under test. 3.3 Test current The current controlled by the measuring device that causes a voltage drop in the circuit under test.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 18216.3-2021_English be delivered?

Answer: Upon your order, we will start to translate GB/T 18216.3-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 18216.3-2021_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 18216.3-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 18216.3-2021?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 18216.3-2021 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.