Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 16275-2008 English PDF

US$529.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 16275-2008: Urban rail transit lighting
Status: Valid

GB/T 16275: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 16275-2008529 Add to Cart 4 days Urban rail transit lighting Valid
GB/T 16275-1996399 Add to Cart 3 days Standard for subway lighting Obsolete

Similar standards

QB/T 2590   GB/T 40258   GB 16410   GB/T 20907   GB/T 14227   GB/T 12758   

Basic data

Standard ID: GB/T 16275-2008 (GB/T16275-2008)
Description (Translated English): Urban rail transit lighting
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: Q84
Classification of International Standard: 93.080
Word Count Estimation: 23,263
Date of Issue: 2008-12-23
Date of Implementation: 2009-06-01
Older Standard (superseded by this standard): GB/T 16275-1996
Regulation (derived from): National Standard Approval Announcement 2008 No.21 (Total No.134)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the lighting of urban rail transit operators in the general provisions of the various places, lighting illuminance values ??, emergency lighting, lighting quality and lighting power density. This standard applies to the lighting of urban rail transit operators all places. This standard does not apply to the lighting of urban rail transit vehicles.

GB/T 16275-2008: Urban rail transit lighting

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Urban rail transit lighting ICS 93.080 Q84 National Standards of People's Republic of China Replacing GB/T 16275-1996 Urban Rail Transit Lighting Posted 2008-12-23 2009-06-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 General provisions 4 5 4 illumination standard values 6 emergency lighting, lighting on duty and transition lighting 5 7 7 lighting quality 8 8 energy-saving lighting 9 9 operation and maintenance and measurement Appendix A (informative) illumination and lighting settings for 11 species Annex B (informative) lighting Select 12 Annex C (informative) Lighting and its annex Select 13 Annex D (informative) set up 14 evacuation lighting Appendix E (normative) transition lighting calculations 15 Annex F (normative) unified glare values \u200b\u200b(UGR) 17 References 19

Foreword

This standard replaces GB/T 16275-1996 "underground railroad lighting standards," compared with the GB/T 16275-1996 main changes are as follows. --- Change the standard name; --- Adjust the scope of the standard; --- Change the value of the illuminance standard formulation method using a single standard illuminance value alternative to low, middle, and high value; --- According to the standard scope of changes in the lighting situations; --- Changed the method of presentation in the glare lighting quality limits, uniform glare value (UGR) Alternative brightness limit curve; --- Increased light, lamp selection of related content; --- Increasing the value of energy efficiency standards for lighting. lighting power density (W/m2) as well as natural light lighting related content. This standard Appendix E, Appendix F for the normative appendix, Appendix A, Appendix B, Appendix C, Appendix D is an informative annex. The standard proposed by the Ministry of Housing and Urban-Rural Development of the People's Republic of China. This standard by the National Standardization Technical Committee on Urban Rail Transit (SAC/TC290) centralized. This standard was drafted. Beijing Subway Operation Co., Ltd., Beijing Subway Operation Co. Design Institute of Guangzhou Metro Road Corporation, Guangzhou Metro Design & Research Institute, Tianjin Metro Corporation, Beijing Metro Electrical Company, Shanghai Shentong Rail Transit Research and Consulting Co., Ltd., Beijing Urban Construction Design Institute, Wuhan Rail Transit Co., Ltd., Changchun Bus Factory Industry Company electrical plant. The main drafters of this standard. Wen Zhiwei, Zhouji Bo, Chen Hua, Xu Yanhua, Li Shengli, Ma Jian students, Pengji Hong, Jin Shoujie, Huyi Nong, Wang Dan, Wang Chunyan, MULTIPURPOSE at?, Zhou Jianhong, Yuan Xin. This standard replaces the standards previously issued as follows. --- GB/T 16275-1996. Urban Rail Transit Lighting

1 Scope

This standard specifies the lighting of urban rail transit operations each places a general rule, the value of illuminance lighting, emergency lighting, lighting quality and lighting Power density. This standard applies to the lighting of urban rail transit operations each workplace. This standard does not apply to lighting urban rail transit vehicles.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 5700 Interior Lighting Measurement GB 7000.1 lamps - Part 1. General requirements and tests (GB 7000.1-2007, IEC 60598-1.2003, IDT) GB 7000.2 Luminaires - Part 2-22. Particular requirements for emergency lighting (GB 7000.2-2008, idt IEC 60598-2- 22.2002) GB 17625.1 Electromagnetic Compatibility Limits for harmonic current emissions (equipment input current ≤16A) (GB 17625.1- 2003, IEC 61000-3-2.2001, IDT) Equipment GB 17625.2 Electromagnetic compatibility limits of the rated current per phase ≤16A and unconditional access in public low-voltage power supply system Voltage generated in the system, voltage fluctuations and flicker limits (GB 17625.2-2007, IEC 61000-3-3.2005, IDT) GB 17896 for tubular fluorescent lamp ballast energy efficiency of limited value and energy conservation evaluation values GB 17945 fire emergency lighting (GB 17945-2000, neq ISO 6309. 1987) GB 19574 high pressure sodium lamp ballasts energy efficiency of limited value and energy conservation evaluation values GB 19043 double capped fluorescent lamps for general lighting energy efficiency limit value and energy efficiency rating GB 19044 for general lighting self-ballasted fluorescent energy efficiency limit value and energy efficiency rating GB 19415 Single-capped fluorescent lamps energy efficiency limit value and energy efficiency rating GB 19573 HPS energy efficiency limit value and energy efficiency rating GB 20053 metal halide lamp ballasts energy efficiency limit value and energy efficiency rating GB 20054 metal halide lamp energy efficiency limit value and energy efficiency rating GB/T 50033 architectural lighting design standards

3 Terms and Definitions

The following terms and definitions apply to this standard. 3.1 To illuminate the whole place and set up uniform illumination. [JGJ/T 119-2008 3.1.1] 3.2 A particular area, such as working otherwise, be designed with different illumination to illuminate the area in general lighting. [JGJ/T 119-2008 3.1.3]
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 16275-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 16275-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 16275-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 16275-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 16275-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 16275-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.