Home   Cart   Quotation   Policy   About-Us
www.ChineseStandard.net
SEARCH

GB 7260.2-2009 English PDF

US$729.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB 7260.2-2009: [GB/T 7260.2-2009] Uninterruptible power systems (UPS) -- Part 2: Electromagnetic compatibility (EMC) requirements
Status: Valid

GB 7260.2: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB 7260.2-2009729 Add to Cart 5 days [GB/T 7260.2-2009] Uninterruptible power systems (UPS) -- Part 2: Electromagnetic compatibility (EMC) requirements Valid
GB 7260.2-2003RFQ ASK 6 days Uninterruptible power systems (UPS) -- Part 2: Electromagnetic compatibility (EMC) requirements Obsolete

Similar standards

GB 7260.1   GB/T 5008.3   GB/T 5008.2   GB/T 7260.3   GB/T 7260.1   GB/T 7260.40   

Basic data

Standard ID: GB 7260.2-2009 (GB7260.2-2009)
Description (Translated English): [GB/T 7260.2-2009] Uninterruptible power systems (UPS) -- Part 2: Electromagnetic compatibility (EMC) requirements
Sector / Industry: National Standard
Classification of Chinese Standard: K85
Classification of International Standard: 29.200
Word Count Estimation: 28,268
Date of Issue: 2009-05-06
Date of Implementation: 2010-02-01
Older Standard (superseded by this standard): GB 7260.2-2003
Adopted Standard: IEC 62040-2-2005, IDT
Regulation (derived from): Announcement of Newly Approved National Standards No. 6, 2009 (No. 146 overall)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This Chinese standard applies to Uninterruptible power supply (UPS) suitable for installation in the following places UPS: UPS or single interconnected by a number of UPS units with associated controller/switch device structure consisting of a single power supply UPS system, connected to the industry, residential, commercial and light industrial low-voltage power supply system operator can reach any area or separate electrical sites. The following definitions are intended as part of the Class C1, C2 and C3 class products placed on the market before the EMC product standard conformity assessment. C4 type of equipment as a fixed installation process. Use spaces are usually in their final installation check. Sometimes part of the installation is completed prior to inspection. See Appendix E. Selection of these requirements is to ensure the UPS in public or industrial sites has the appropriate level of electromagnetic compatibility. However, these levels can not be covered in any place can happen, but the probability is very low extremes. This standard considers the physical size of the UPS and power ratings ranging from the different experimental conditions. As a standalone product, UPS units or UPS system should meet the relevant requirements of this standard, but should not consider the user to connect the output of the UPS device any load generated by EMC phenomena. This standard does not cover the special installation environment, but also does not consider the UPS fault conditions. This standard does not cover the DC -powered electronic ballasts or on rotary unit UPS. This standard provides: EMC requirements, test methods, minimum performance level.

GB 7260.2-2009: [GB/T 7260.2-2009] Uninterruptible power systems (UPS) -- Part 2: Electromagnetic compatibility (EMC) requirements


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Uninterruptible power systems (UPS) .Part 2. Electromagnetic compatibility (EMC) requirements ICS 29.200 K85 National Standards of People's Republic of China GB 7260.2-2009/IEC 62040-2.2005 Replacing GB 7260.2-2003 Uninterruptible power supplies (UPS) Part 2. Electromagnetic Compatibility (EMC) requirements (IEC 62040-2.2005, IDT) Published 2009-05-06 2010-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China issued

Table of Contents

Preface Ⅰ 1 Scope 1 2 Normative References 1 2 3 Definitions 4 Environmental 2 5 UPS category 2 Class 5.1 C1 UPS 2 5.2 C2 class UPS 2 5.3 C3 class UPS 3 5.4 C4 class UPS 3 5.5 UPS's relations with the applicable environmental category 3 6 emitted 3 6.1 Overview 3 6.2 General Requirements 3 3 6.3 general measurement conditions 6.4 conduction emission 4 6.5 Radiation emitted 5 7 6 Immunity 7.1 Overview 6 7.2 General requirements and performance criteria 6 7.3 Basic immunity requirements --- high-frequency harassment 7 7.4 low frequency signal Immunity 8 7.5 Power frequency magnetic field immunity 8 7.6 Voltage dips, short interruptions and voltage variations immunity 8 Annex A (normative) Test method for electromagnetic emissions 9 (Informative) The method of measuring electromagnetic emission limits and magnetic field (H-field) Appendix B 19 Annex C (normative) signal port 20 of electromagnetic emission limits Annex D (normative) Electromagnetic immunity Test Method 21 Annex E (informative) test users to install 23 GB 7260.2-2009/IEC 62040-2.2005

Foreword

All technical contents of this section is mandatory. "Uninterruptible power supply (UPS)" is currently divided into the following sections. --- Part of 1-1. UPS general and safety requirements for use in operator access area; --- Part 1-2. UPS restricted access areas using a general and safety requirements; --- Part 2. Electromagnetic Compatibility (EMC) requirements; --- Part 3. Determination of the test and performance requirements. This section "Uninterruptible power supplies (the UPS)," Part 2, identical with IEC 62040-2.2005 "Uninterruptible Power Supply (UPS) - Part 2. Electromagnetic Compatibility (EMC) requirements "(in English). This part of the IEC 62040-2.2005 errata footnote Mark. 6.2 and 6.3 --- referenced 5.3 and 5.4 should be 6.4 and 6.5; --- 7.5 The "C1 categories. Level 2 (10A/m); C2 and C3 classes classes. Level 3 (30A/m)" should be "C1 categories. Level 3 (10A/m); Class C2 and C3 classes. Level 4 (30A/m) "; --- Figure D. Voltage 230V 2 should be 400V. This partial replacement GB 7260.2-2003 "Uninterruptible Power Supply (UPS) - Part 2. Electromagnetic Compatibility (EMC) requirements." This section compared with GB 7260.2-2003, major changes are as follows. --- using C1, C2, C3 and C4 in place by classification limits of sales and sales of non-limits the UPS classification points Type, including not only the emission limit requirements, but also the corresponding immunity requirements; --- is greater than the rated current of 400A UPS power supply terminal and the AC output voltage interference limit there is no separate, direct electrical rated comprising 100A is greater than the flow range UPS; --- lower interference required AC output voltage is greater than the value for the rated current of the UPS 100A; --- higher immunity requirements apply to anticipated operational in commercial and industrial environments of UPS; --- increased electromagnetic emission measurement method described in the magnetic field (H-field) in Appendix B; --- cancel the original standard Appendix E "UPS decay test methods", instead the user to install the test. Appendix A and Appendix D of this section is normative, Appendix B, Appendix C and Appendix E is an information appendix. This section was proposed by China Electrical Equipment Industrial Association. This part of the jurisdiction of the National Power Electronics Standardization Technical Committee (SAC/TC60). This section is responsible for drafting. Shanghai Electrical Apparatus Research Institute (Group) Co., Ltd., Shanghai Fudan Fuhua Technology Co., Ltd. It participated in the drafting of this section. Xi'an Institute of Power Electronics, Ai Mosheng Network Power Co., Ltd., Shanghai Sanki has Limited, Guangdong Zhicheng Champion Group Co., Merlin Gerin Electronics (China) Co., Ltd., Qingdao Economic and Technological Development Zone of Science and Technology Commission issued Exhibition Co., Ltd. The main drafters of this section. Shou Jian Xia, Wang Ao students, Li Ruilin, Lee Min-Ying, Li Shuguang, Sui Xueli, become a red flag, Qian Wei, Wang Weihui, Zhang sound. This section was first released in 2003, this is the first revision. GB 7260.2-2009/IEC 62040-2.2005 Uninterruptible power supplies (UPS) Part 2. Electromagnetic Compatibility (EMC) requirements Range 1 "Uninterruptible power supplies (the UPS)" This section applies to the following locations mounted UPS. --- single UPS or composed of several single power supply UPS interconnected with the associated controller/switching device consisting of UPS systems; --- Any operator is connected to the low voltage power supply system of industrial, residential, commercial, and light can reach the area or separate electrical properties. This section is intended as a definition of the following classes C1, C2, and C3 based products for EMC conformity assessment of products in the market before standard. Category C4 as a fixed installation process. Usually checked after their end-use installation site. May be carried out prior to installation portion Check points. See Appendix E. Selection of these requirements is to ensure that UPS has adequate electromagnetic in public or industrial sites compatible level. However, these levels are not Can cover can happen at any place, but the probability is very low in extreme cases. This section considers the different experimental conditions and the physical dimensions of the UPS power rating of the covering. As a separate product, or UPS unit UPS system should meet the requirements of this section, but should not be considered connected to the UPS user Any EMC phenomenon generated by the load of the output of the device. This section does not cover a particular installation, without regard for UPS failure. This section does not cover the electronic ballast or DC powered rotary unit based UPS. This section provides. --- EMC requirements; ---experiment method; --- lowest level performance.

2 Normative references

Terms of the following documents constitute provisions of this section by reference in this section. For dated reference documents, all later Amendments (not including errata content) or revisions do not apply to this section, however, encourage the parties to agreements based on research of Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB/T 4365-2003 Electrotechnical term EMC (IEC 60050-161.1990, IDT) GB/T 6113.101-2008 radio disturbance and immunity measuring apparatus and methods - Part 1-1. Radio Sao Disturbance and immunity measuring apparatus measuring equipment (CISPR16-1-1.2006, IDT) GB/T 6113.102-2008 radio disturbance and immunity measuring apparatus and methods - Part 1-2. Radio Sao Interference immunity measuring apparatus and ancillary equipment Conducted disturbances (CISPR16-1-2.2006, IDT) GB/T 7260.3-2003 uninterruptible power supply (UPS) - Part 3. Method of determining the performance test requirements and (IEC 62040-3.1999, MOD) Limits and methods of measurement GB harassment radio 9254-2008 Information technology equipment (CISPR22.2006, IDT) GB 17625.1-2003 electromagnetic compatibility limits for harmonic current emissions (equipment input current ≤16A) (IEC 61000-3-2.2001, IDT) GB/T 17626.1-2006 Electromagnetic compatibility testing and measurement techniques Overview of immunity tests (IEC 61000-4-1.2000, IDT) GB 7260.2-2009/IEC 62040-2.2005 GB/T 17626.2-2006 Electromagnetic compatibility testing and measurement techniques electrostatic discharge immunity test (IEC 61000-4-2.2001, IDT) GB/T 17626.3-2006 Electromagnetic compatibility testing and measurement techniques RFEMS test (IEC 61000-4- 3.2002, IDT) GB/T 17626.4-2008 Electromagnetic compatibility testing and measurement techniques Electrical fast transient burst immunity test (IEC 61000- 4-4.2004, IDT) GB/T 17626.5-2008 Electromagnetic compatibility testing and measurement techniques surge (impact) immunity test (IEC 61000-4-5. 2005, IDT) GB/T 17626.6-2008 Electromagnetic compatibility testing and measurement techniques conducted disturbances induced by radiofrequency fields Immunity (IEC 61000- 4-6.2006, IDT) GB/T 17626.8-2006 Electromagnetic compatibility testing and measurement techniques frequency magnetic field immunity test (IEC 61000-4-8.2001, IDT) IEC 61000-2-2.2002 Electromagnetic compatibility (EMC) Part 2-2. Environmental low voltage power supply system and the electrical frequency conducted disturbances Compatible network transmission of electromagnetic signals

3 Terms and Definitions

In addition to this section and defined in terms of using a predetermined GB/T 4365, the following terms and definitions supplement. 3.1 UPS interface with special external electromagnetic environment, shown in Figure 1. 3.2 UPS may transmit an electromagnetic field and invasive physical interface. FIG port Example 1

4 Environmental

The following environment covering the majority of the UPS installation site. a) Class 1 Environment. without intermediate transformer is directly connected to the residential, commercial, and light industrial areas public low-voltage power supply system; b) second environment. not directly connected to the low voltage power supply system for a residential building supply are all commercial area, and light industrial areas Industry area.

5 UPS category

5.1 C1 class UPS This class is suitable for Class 1 UPS environment, without any restrictions. This class UPS for residential facilities. C1-based UPS class should satisfy emission limits and immunity requirements Table 5. 5.2 C2 class UPS Such UPS output current not exceeding 16A, without any restrictions applicable to the second environment. As one of the following connections, GB 7260.2-2009/IEC 62040-2.2005 This class UPS also applies to Class 1 environment. --- using industrial plugs and sockets; --- national standard plugs, sockets; --- permanent connection. Class C2 UPS class should meet emission limits and immunity requirements in Table 6. Moreover, we should have the following text in the product description. Warning. This product is a Class C2 UPS, for residential installation might need to take additional measures to restrict or suppress RF harassment. 5.3 C3 class UPS Such UPS output current exceeds 16A, suitable for second environment. When the class UPS for commercial and industrial facilities, should first distance 1 building class environment at least 30m. C3-based UPS class should satisfy emission limits and immunity requirements in Table 6. Moreover, we should have the following text in the product description. Warning. This product is for Class 2 environment for commercial and industrial use. You may need to take additional measures to restrict or install suppression Harassment. 5.4 C4 class UPS This class is suitable for UPS complex environment, its emission limits and immunity requirements shall be the purchaser and the supplier/vendor negotiation. C4 UPS class of unrestricted current rating requirements. 5.5 UPS's relations with the applicable environmental category If the environmental conditions the environment is determined to be a category 1, category C1 or C2 should use UPS. If the environmental conditions determined second environment, you should use the class C2 or C3 UPS. If the ambient conditions do not belong to Class 1 or Class 2 Environment environment, should be chosen category C4 UPS.

6 launch

6.1 Overview This section relates to harassment 0Hz ~ 1.0GHz frequency range. The purpose of determining the emission requirements is to ensure the normal operation of the UPS, resulting not reach harassment interfere with the normal operation of other equipment degree. Note 1. When the class 10m C1 or C2 class UPS receiving antenna distance, 30m C3-based UPS provided with distance, this part can not be sufficiently guaranteed limit Radio and television reception interference. Note 2. If the UPS devices in the vicinity of the high sensitivity, inhibition may have to take additional measures to make the electromagnetic emission is further reduced to a predetermined level. 6.2 General requirements UPS should meet emission limits specified in 6.4 and 6.51). 1) and 6.3 of this article, the original mistake many as 5.3, 5.4. UPS should be tested under the following conditions. --- rated input voltage; --- operating in a normal mode of operation and storage operation mode; --- UPS can access maximum disturbance level of linear load. 6.4 purpose is to within predetermined limits and measurement methods related to the scope of this electromagnetic emission, which can emit electromagnetic other settings Preparation of (e.g., radio receiver) is disturbed. These emission limits are essential electromagnetic compatibility requirements. Test requirements are specified for each port. See Appendix A. Test Method 6.3 general measurement conditions 6.3.1 Overview Maximum emission measurement the EUT should be generated at frequency band and in accordance with normal working state detection applications, UPS work GB 7260.2-2009/IEC 62040-2.2005 As. normal mode and storage mode of operation. By changing the maximum emission test test arrangement UPS. With respect to the additional power source terminal (port) as a stationary bypass circuit and/or maintenance bypass circuit independent power supply UPS, whenever possible, it These additional power supply terminals (ports), should be properly connected to the AC input port of the temporary power supply. 6.4 conduction emission tests should include these Measuring additional circuit. If UPS is part of the system, or may be connected to the auxiliary device, the UPS must simply connect the use of the test ports Minimum assistance device, or equivalent port impedance termination. UPS AC output terminal connected to the linear load can be run under any load conditions in rated output range. Test description should be precise arrangement and mode of operation, the test and measurement arrangement of the guidelines when measured in the test report Appendix A, field test See Appendix E. Should, be tested at its rated input voltage is within a predetermined range of UPS runtime environment, unless otherwise indicated. 6.3.2 the buyer, user files a) If in order to achieve compliance and the need to take special measures, it must inform the buyer, user, for example, the use of shielded cable or dedicated Cable, any limitations should be described in detail in the AC output cable length; b) the buyer user needs document should be sent on the letter, and the list of auxiliary devices UPS emission requirements should be performed together with the file provide. 6.3.3 Applicability Measured at the relevant port UPS. 6.4 conduction emission 6.4.1 supply terminal disturbance voltage limit According to the type and the rated output current of the UPS should not exceed the limit disturbance voltage table 1 or Table 2. When using the average detector receiver, respectively, and a quasi-peak detector receiver, UPS should satisfy two kinds of average and quasi-peak limit Value in accordance with Appendix A. A Method 6 a predetermined measure. When using a quasi-peak detector receiver measurements, if the average value satisfied, the test apparatus that satisfies the two limits to Seeking, without the receiver and then measuring an average detector. If the readings on the receiver shown fluctuate around limits, the frequency of readings at each measurement observation time should be less than 15s, Record maximum readings, any isolated moments of great reading should be ignored. a) C1 and C2 based UPS class b) C3-based UPS Table 1 in the z ~ 30MH z 0.15MH frequency range, the power supply terminal disturbance voltage limit classes C1 and C2 of the UPS class Frequency Range/ MHz Limits/dB (μV) Class-based UPS UPS C1 C2 Quasi-peak quasi-peak average value of the average 0.15 ~ 0.50 66 ~ 56a 56 ~ 46a 79 66 0.50 ~ 5.0b 56 46 73 60 5.0 ~ 30.0 60507360 A limit value of the log-linear decrease with frequency. b transition frequency lower limit should apply. GB 7260.2-2009/IEC 62040-2.2005 Table 2 in the z ~ 30MH z 0.15MH frequency range, the power supply terminal disturbance voltage limits of the UPS class C3 UPS rated output current / Frequency Range/ MHz Limits/dB (μV) Quasi-peak average value > 16, but ≤100 0.15 ~ 0.50b 100 90 0.50 ~ 5.0b 86 76 5.0 ~ 30.0 90 ~ 70a 80 ~ 60a > 100 0.15 ~ 0.50b 130 120 0.50 ~ 5.0b 125 115 30.0 5.0 115 105 A limit value of the log-linear decrease with frequency. b transition frequency lower limit should apply. 6.4.2 AC output voltage limit harassment Limits specified in applicable Table 1 and Table 2. In addition to the above category C3 IOOA UPS, the Table 1 and Table 2 provides a conductive UPS output disturbance limits allow increased 14dB. These limits apply only to the case of the cable length UPS manufacturers instructions for its use of more than 10m is declared. It should be used in line A. 2.3 voltage probes to measure these values. 6.4.3 limit signal port and communication port Quasi port connected to a public communication network (PSTN), using the test methods and limits (see Appendix C) specified in GB 9254. 6.4.4 limit DC port DC UPS port is considered an internal port, and thus not conducted interference value limit. Conducted interference caused by the DC port may be made To radiated interference, as long as the UPS is operating in normal operation mode and a storage mode of operation and arranged in this chapter comply with the emission requirement 6.5, Further tests are no longer required. The UPS with a terminal connected to the external power source, the port should be included in the test configuration, according to the following test methods. Desktop UPS battery and battery box to be installed in a position to allow the manufacturer instructions. The external power source of the floor-UPS Its direct current source should be mounted in the housing at a distance UPS0.8m, according to the manufacturer's instructions and the wiring. The external power source should be large UPS UPS certain distance away from the installation, the port should be instructed by the manufacturers specification, a wiring, and configure the appropriate test current source end of the cable Or battery power to ensure that the measurement operation in the storage mode. 6.4.5 low input current harmonics emission --- If the rated current and the input voltage is within a predetermined range GB 17625.1, harmonic current limits the reference standards and test methods. 6.5 radiation emission 6.5.1 electromagnetic field UPS should meet the limits in Table 3. I......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 7260.2-2009_English be delivered?

Answer: Upon your order, we will start to translate GB 7260.2-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 7260.2-2009_English with my colleagues?

Answer: Yes. The purchased PDF of GB 7260.2-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB 7260.2-2009?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 7260.2-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.


Refund Policy     Privacy Policy     Terms of Service