Standard ID: GB 21240-2007 (GB21240-2007)
Description (Translated English): Safety rules for the construction and installation of hydraulic lifts
Sector / Industry: National Standard
Classification of Chinese Standard: Q78
Classification of International Standard: 91.140.90
Word Count Estimation: 132,129
Date of Issue: 2007-11-01
Date of Implementation: 2008-01-01
Quoted Standard: GB/T 700-2006; GB/T 786.1-1993; GB/T 2423.5-1995; GB/T 2423.6; GB/T 2423.10-1995
Adopted Standard: EN 81-2-1998, MOD
Regulation (derived from): China Announcement of Newly Approved National Standards No. 12 of 2007 (No. 112 overall)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This Chinese standard specifies the permanent installation of a new hydraulic elevator manufacture and installation shall comply with the safety guidelines. This standard applies to the car by a hydraulic cylinder supported or suspended by a rope or chain and with the vertical gradient of not greater than 15 �� between the running rails for transporting passengers or goods to the designated landing hydraulic lift. In addition to the standard requirements, should be considered in exceptional circumstances (potentially explosive environment, adverse weather conditions, seismic conditions, the transport of dangerous goods, etc.) for additional requirements.

GB 21240-2007: Safety rules for the construction and installation of hydraulic lifts

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Safety rules for the construction and installation of hydraulic lifts ICS 91.140.90 Q78 National Standards of People's Republic of China Hydraulic elevator manufacturing and installation safety specifications (EN81-2..1998, Safetyrulesfortheconstructionandinstalationoflifts- Part 2. Hydrauliclifts, MOD) Posted on.2007-11-01 2008-01-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Introduction Ⅶ EN81-2 Introduction Ⅸ 0.1 General Ⅸ 0.2 Principle Ⅸ 0.3 Assumption X. 1 Scope 1 2 Normative references 1 3 Terms and definitions 3 4 units and symbols 5 4.1 unit 5 4.2 symbol 5 5 wells 5 5.1 General 5 5.2 Well closed 5 5.3 shaft wall, floor and roof 8 5.4 Facing the car entrance layer door and hydraulic elevator shaft wall structure 9 5.5 in the car or balance the lower part of the space protection 9 5.6 within the shaft protection 9 5.7 Top Space and Pit 9 5.8 special hoistway 11 5.9 shaft lighting 11 5.10 emergency solution 11 6 room and between the pulley 11 6.1 General 11 6.2 channel 11 6.3 room structure and equipment 12 6.4 pulley between the structure and equipment 13 7-storey door 14 7.1 General 14 7.2 Door and its frame strength 14 7.3 The height and width of the door entrance 14 7.4 ridge, guide and door suspension mechanism 15 7.5 Protection with landing movement 15 7.6 Local lighting and "car in this" signal 16 7.7 Layer Door Locking and Closing Inspection 16 7.8 Power-driven automatic door close 18 8 car and balance weight 18 8.1 car height 18 8.2 The effective area of the car, the rated capacity, the number of passengers 18 8.3 car wall, car floor and car top 20 8.4 Foot plate 21 8.5 Car Entrance 21 8.6 Car door 21 8.7 Car door protection during movement 22 8.8 The process of closing the anti-open 22 8.9 Verify that the car door is closed 8.10 Multi-Sliding Door Mechanically Connected 23 8.11 Opening of the car door 23 8.12 car safety window and car safety door 8.13 car top 24 8.14 car guard 24 8.15 car roof device 24 8.16 Ventilation 24 8.17 Lighting 24 8.18 balance weight 25 9 Suspension, Preventing Falling, Speeding Down and Prevention of Car Settlements 25 9.1 Suspension 25 9.2 pulley rope diameter ratio, wire rope or chain termination device 25 9.3 Load distribution between ropes or chains 25 9.4 Protection of pulleys and sprockets 26 9.5 to prevent the car falling, speeding down and settlement prevention measures 26 9.6 Precautions to Prevent a Counterweight from Falling Down 28 9.7 (omitted) 28 9.8 safety gear 28 9.9 Clamping device 29 9.10 safety gear and clamping device triggering method 30 9.11 Pawl device 32 9.12 Electrical anti-settling system 33 10 rails, buffers and limit switches 33 10.1 General guide rails Car and counterweight guidance 10.3 Car Buffer 34 10.4 Car buffer stroke 34 10.5 limit switch 35 11 car and the hoistway wall facing the entrance of the car, and the distance 36 between the car and the counterweight 11.1 General 36 11.2 The distance between the car and the hoistway wall facing the car entrance 36 11.3 car and balance weight spacing 37 12 drive host 37 12.1 General 37 12.2 Hydraulic cylinder 37 12.3 Piping Configuration 39 12.4 stop driving the host and check its stop status 40 12.5 Hydraulic Control and Safety Device 40 12.6 Hydraulic System Pressure Check 42 12.7 Fuel tank 42 12.8 speed 42 12.9 Emergency Operations 42 12.10 Protection of pulleys or sprockets on hydraulic cylinders 43 12.11 Protection of Mechanical Components 43 12.12 Motor Running Time Limiter 43 12.13 loose rope (or loose chain) safety devices for indirect acting hydraulic elevators 12.14 Hydraulic System Hydraulic Oil Overheat Protection 43 13 Electrical Installation and Electrical Equipment 43 13.1 General 43 13.2 Contactor, relay contactors, safety circuit components 44 13.3 Protection of motors and other electrical equipment 45 13.4 Main switch 45 13.5 Electrical Wiring 45 13.6 Lighting and Socket 46 Protection, control, priority of electrical faults 47 14.1 Failure Analysis and Electrical Safety Devices 47 14.2 Control 50 15 Notes, Marking and Operating Instructions 52 15.1 General 52 15.2 Inside the car 15.3 car top 53 15.4 Room and pulley 53 Well 15.5.5 15.6 Speed Governor 54 15.7 Pit 54 15.8 Buffer 54 15.9 Identification of landing 54 15.10 Electrical Identification 54 15.11 Door unlocking key 54 15.12 Alarm 54 15.13 Door Lock 54 15.14 Safety gear 54 15.15 emergency valve down 54 15.16 Manual pump 54 15.17 Group control elevator 55 15.18 Fuel tank 55 15.19 Rupture valve/check valve 55 Inspection, Recording and Maintenance 55 16.1 Test 55 16.2 Record 55 16.3 Installation Materials 56 Appendix A (Normative) Electrical Safety Devices Table 57 Appendix B (Normative) Unlock the triangle key 58 Appendix C (Informative) Technical Paper 59 C. 1 Introduction 59 C. 2 Overview 59 C. 3 Technical Details and Floor Plans 59 C. 4 Schematic diagram of electrical and hydraulic system Figure 60 C. 5 compliance verification 60 Appendix D (Normative) Inspection before delivery 61 D. 1 check 61 D. 2 Tests and Verification 61 Appendix E (informative) periodic inspection, major modifications or post-accident inspection 65 E. 1 regular inspection 65 E. 2 major modifications or post-accident inspection 65 Appendix F (Normative) Type test certification procedures for safety components 66 F. 0 Introduction 66 F. 1 floor door lock device 68 F. 2 (slightly) 70 F. 3 safety gear 70 F. 4 speed limiter 74 F. 5 buffer 75 F. Safety circuit containing electronic components F. 7 rupture valve, one-way throttle 80 Appendix G (informative) guide rail 84 G. 1 Overview 84 G. 2 load and external force 84 G. 3 load conditions 85 G. 4 impact coefficient of 85 G. Calculate 86 G. 6 allowable deflection 90 G. Example of calculation method 90 Appendix H (Normative) Troubleshooting electrical components 105 Appendix J (Normative) Pendulum impact test 109 J. 1 Overview 109 J. 2 test stand 109 J. 3 panel 109 J. 4 Test Procedure 109 J. 5 test results show 109 J. 6 Test Report 110 J. Exceptions to the test Appendix K (Normative) Plunger, cylinder, pipe and accessories calculation 114 K. 1 against over-voltage calculation 114 K. 2 hydraulic cylinder compression bending calculation 115

Foreword

This standard Chapter 1 ~ Chapter 4 and 7.2.1, 8.17.1, 9.1.2b), 9.10.6.2a), 12.6.3, 12.8.2, 13.1.1.3, 15.2.3.2, 16.2a) 6), 16.2a) 7) with the word "should", Appendix C, Appendix E, Appendix G is the recommended terms, the rest is mandatory Sexual terms. This standard is amended to adopt the European standard EN81-2..1998 "elevator manufacturing and installation of safety norms Part 2. hydraulic lift" (British Version). This standard is based on EN81-2..1998 redrafted. This standard and EN81-2..1998 technical differences and their causes. --- Part 2 of this standard "normative references" with part of our standard instead of the corresponding European standards and international standards, increase GB/T 7024.1-1997, cancel prEN81-8..1997. --- This standard Chapter 3 "Terms and Definitions" is no longer included in the GB/T 7024 in the terms and definitions have been, such as foot guards, bumpers, Car, Freight elevator, Rail, Pedestal, Instantaneous safety gear, Instantaneous safety gear with cushioning, Flat, Speed limiter, Pit, progressive safety gear, safety gear, accompanying cables, unlocking zone, hoistway, retaining terms that need to be specifically described and definition. --- EN81-2..1998 7.1 paragraph 2, replaced by the following in this standard. "For the hydraulic passenger lift, this transport Moving space should not be greater than 6mm. For hydraulic lifts, this clearance must not exceed 8 mm. Due to wear, clearance values allow Reach 10mm. If there is a recess, the above clearance is measured from the indentation. " --- This standard EN81-2..1998 8.2.1 add the following. "For hydraulic passenger lift and hydraulic bed elevators, in order to Allow changes in the design of the car, the rated capacity listed in Table 1 corresponds to the maximum allowable car maximum area of the car is allowed to increase not more than the table The area of 5% of the column value. "To consider China's hydraulic elevator car design changes in the area. --- This standard EN 8.2-2 in EN 8.2-2 added the following terms. "8.2.2.5 For specifically approved and trained Commercial use of non-commercial hydraulic car elevator, the rated load should be based on the effective area of a car unit is not less than.200kg (ie 200kg/m2) calculation. "To consider the actual situation of non-commercial hydraulic car elevator in our country. --- EN81-2..1998 8.6.3 "This movement gap shall not be greater than 6mm", in this standard "For hydraulic passenger elevators, This movement gap can not be greater than 6mm. For hydraulic cargo elevator, this clearance shall not be greater than 8mm "instead, for hydraulic cargo Elevator, the gap properly relaxed. --- This standard in EN81-2..1998 9.5.1 Table 3 (Table 9.5.1 of this standard) added the following instructions to further explain The meaning of this table. --- Delete EN81-2..1998 9.8.2.1b) in the content, because there is no buffer in our country instantaneous security Full clamp. --- Delete EN81-2..1998 9.8.6.2 content, the same reasons as Article 8. --- Deletion EN81-2..1998 10.3.5b) "Accumulator type with cushioning effect" because there is no such type of shock absorber in our country. --- EN81-2..1998 10.3.8 "Non-linear storage bumpers and/or storage bumpers with cushioning reset movement and Energy-saving bumper "to" Linear and non-linear bangles and energy-efficient bumpers ", by deleting" and/or Energy storage buffer with cushioning reset motion "because there is no such type of buffer in our country. --- Delete EN81-2..1998 of the contents of 10.4.2, because our country does not have this type of buffer. --- This standard EN 81-2..1998 added in the content of 12.3.3.3 "--- Permissible bending radius", because the hose is fixed When its bending radius is not less than the bending radius specified by the manufacturer. --- This standard EN81-2..1998 in the contents of 12.5.7 increase "manual emergency valve in the loop can not set the filter", Because the hydraulic circuit without setting oil filter. --- EN81-2..1998 Appendix D. 2h) 1) "Instantaneous safety gear or momentary safety gear with cushioning effect" Standard with "instantaneous safety gear" instead, "safety gear should be carried out at rated speed" action "safety gear in the overhaul Speed "instead, Appendix D.2h) 1) i)" Car with 125% of the rated load, unless the rated load is less than the table 1.1 (8.2.1) Carriage load given value does not exceed the corresponding load capacity in Table 1.1 "Used" for the hydraulic cargo described in 8.2.2 Elevator, car test load according to the actual area of the car according to Table 1 to determine "instead of taking into account the actual situation of China's hydraulic lift And ensure safety. --- EN81-2..1998 Appendix D. 2h) 2) The contents of "safety gear movements at rated speed or lower speed," in this Standard "safety gear action can be rated speed or overhaul speed" instead; EN 81-2..1998 Appendix D. 2h) 2) i) "When the rated load is less than the value given in Table 1.1 (8.2.1), the car shall be fitted with a rating of 125% Unless the load does not exceed the weight of the corresponding Table 1.1 ", in this standard used" for the 8.2.2 hydraulic cargo electricity Ladder, the test load is 125% of the rated load and the actual car area according to the provisions of Table 1 corresponds to the rated load of two In the larger "instead of taking into account the actual situation of hydraulic lift in our country and ensure safety. --- This standard EN81-2..1998 Appendix D 2h) to add a paragraph "for the non-commercial hydraulic vehicles described in 8.2.2.5 Elevator, shall be 150% of the rated load carrying safety gear of the above test "to take into account the actual situation of China's hydraulic car elevator Happening. --- EN81-2..1998 Appendix D. 2i) 1) "Momentary safety gear or momentary safety gear with cushioning. action should be limited Speed or safety rope trigger, the test should be carried out in the car no-load, rated speed ", in this standard using" momentary safety gear. action Should be triggered by the speed limiter or safety rope, the test should be carried out in the car no-load, overhaul speed "instead, in order to avoid the action of the safety gear Rail wear. --- EN81-2..1998 Appendix D. 2i) 2) "Progressive safety gear. the test should be carried out in the car no load, rated speed or lower speed Proceed ", in this standard" Progressive safety gear. the test should be carried out in the car no-load, rated speed or overhaul speed "instead, In order to avoid the action of safety gear lead to the rail wear. --- EN81-2..1998 Appendix F. 5.3.1 "Energy storage buffer with a bump reset motion", in this standard "linear energy storage Type buffer "instead, because our country does not have this type of buffer. The above technical differences have been incorporated into the main text and are marked with a vertical single line in the margins of the clauses to which they relate. This standard Appendix A, Appendix B, Appendix D, Appendix F, Appendix H, Appendix J, Appendix K is a normative appendix, Appendix C, Appendix E, Appendix G is an informative annex. This standard is proposed by the National Elevator Standardization Technical Committee and centralized. This standard is drafted by. China Academy of Building Research Building Mechanization Research Branch. Participated in the drafting of this standard. Schindler (China) Elevator Co., Ltd., Shanghai Mitsubishi Elevator Co., Ltd., Suzhou Schindler Elevator Co., Ltd., Hangzhou Xizi Otis Elevator Co., Ltd., Changsha Construction Machinery Research Institute, Thyssen Elevator Co., Ltd., Shandong Best Elevator Co., Ltd. Zhejiang Jiang Giant Elevator Co., Ltd., Suzhou Jiangnan Elevator Co., Ltd., Suzhou Southeast Hydraulic Elevator Co., Ltd. The main drafters of this standard. Peng Kerong, Chen Fengwang, Cai Jinquan, Wang Xingqi, Zhu Jian, Cheng Bin, Yu Gang, Huang Limin, Chen Yongjian, Li Jinwei, Wei Shanhu, Yang Yingde. EN81-2 Introduction 0.1 General 0.1.1 The standard from the point of view of protection of personnel and goods to develop hydraulic passenger lift and hydraulic cargo elevator safety norms to prevent the occurrence Danger of accidents related to the use of personnel, hydraulic elevator maintenance and emergency operations. 0.1.2 studied the possibility of hydraulic elevator in many kinds of accidents in the following aspects. 0.1.2.1 Danger may be caused by the following accidents. a) Cut. b) Extrusion. c) fall. d) Impact. e) trapped. f) fire. g) Electric shock. h) Material failure due to. 1) Mechanical damage; 2) wear and tear; 3) rust. 0.1.2.2 Protection of personnel. a) user b) maintain and inspect personnel; c) Hydraulic hoistway, room and pulley (if any) outside the staff. 0.1.2.3 protected objects. a) car load; b) components of hydraulic lift; c) Installation of hydraulic elevator building. 0.2 principle The development of this standard, the use of the following principles. 0.2.1 This standard does not include repeat applicable to any electrical, mechanical and building components, including fire protection, including the general structure of the building technology specification. However, it is necessary to devise some requirements to ensure good construction. On the one hand, this is peculiar to the manufacturer of hydraulic elevators On the other hand, because of the use of hydraulic elevators, these requirements may be more stringent than others. 0.2.2 This standard not only expresses the basic safety requirements of the Elevator Directive (theLiftDirective), but also the other Describes the minimum requirements for installing a hydraulic elevator in a building or structure. Some countries (referring to certain member states of the European Community) Building structures and other laws and regulations can not be ignored. The typical terms affected by this. the engine room, the height of the pulley and the minimum size of their entrance door requirements. 0.2.3 When parts can not be moved by hand due to weight, size and/or shape, these parts should. a) Set up attachments to be lifted by lifting gear; or b) It can be designed to be connected with the above lifting attachments (eg by using threaded holes); or c) It is easy to be lifted in shape by the standard lifting equipment. "" "" "But" "" "" "Always" "" "" "" "" "" "" ""/"" "" "" "" "" "" "" "" "•" "" "" "" "" "" "" "" "" Convention "" ""/"" "" "" "" "" "" " 0.2.5 Consultation between customer and supplier. a) the intended use of hydraulic lift; b) Environmental conditions; c) civil engineering issues; d) other aspects of the installation site. 0.3 Assumptions The possible dangers of each component contained within a complete hydraulic elevator have been taken into account. Has developed a corresponding specification. 0.3.1 Parts are. a) Designed in accordance with normal engineering practices and calculations, taking into account all forms of failure; b) reliable mechanical and electrical structure; c) made of a material of sufficient strength and quality; d) No defects. Harmful materials (such as asbestos, etc.) should not be used. 0.3.2 Components shall be properly maintained and in normal working order and shall meet the required dimensions in spite of wear. 0.3.3 Parts selected and configured so as not to affect the safety of the hydraulic elevator under the expected environmental influences and specific working conditions run. 0.3.4 Design of bearing structure shall ensure that the hydraulic elevator can operate safely within the bearing range of 0 ~ 100% of the rated load. 0.3.5 The requirements of this standard for electrical safety devices are. The possibility of failure of an electrical safety device in full compliance with this standard is not Will consider. 0.3.6 When a user uses a hydraulic lift as intended, the problems caused by his own negligence and unintentional carelessness should be To protect. 0.3.7 In some cases, the user may make some kind of reckless move. This standard does not consider the simultaneous occurrence of two reckless moves Possibility and/or violation of the instructions for hydraulic elevators. 0.3.8 If during maintenance, a safety device that the user is not normally accessible is intentionally deactivated, the hydraulic elevator Of the safe operation of non-guaranteed, you should follow the maintenance procedures to take additional measures to ensure the safety of personnel. Suppose maintenance personnel have been trained Training and maintenance work in accordance with the rules. 0.3.9 Horizontal force used. a) static force. 300N; b) The force generated by the impact. 1000N. This is the force one can exert. 0.3.10 In addition to the following, in accordance with good practice and the requirements of this standard manufacturing machinery, in the case can not check, will not Damage to the brink of danger. The following mechanical problems should be considered. a) Suspension of the suspension; b) breakage an......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 21240-2007_English be delivered?

Answer: Upon your order, we will start to translate GB 21240-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 21240-2007_English with my colleagues?

Answer: Yes. The purchased PDF of GB 21240-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.