LST1220-2020: Technical regulation of transverse ventilation for stored grain in warehouses
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
LS/T 1220-2020English529 Add to Cart 3 days [Need to translate] Technical regulation of transverse ventilation for stored grain in warehouses Valid LS/T 1220-2020

PDF similar to LST1220-2020


Standard similar to LST1220-2020

SN/T 0800.1   LS/T 6103   SN/T 0800.18   LS/T 1224   LS/T 1225   LS/T 1213   

Basic data

Standard ID LS/T 1220-2020 (LS/T1220-2020)
Description (Translated English) Technical regulation of transverse ventilation for stored grain in warehouses
Sector / Industry Food & Beverage Industry Standard (Recommended)
Classification of Chinese Standard B20
Classification of International Standard 65.040.20
Word Count Estimation 23,284
Date of Issue 2020-01-21
Date of Implementation 2020-07-21
Issuing agency(ies) National Grain and Material Reserves Administration

LST1220-2020: Technical regulation of transverse ventilation for stored grain in warehouses

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Technical regulation of transverse ventilation for stored grain in warehouses ICS 65.040.20 B20 People's Republic of China Food Industry Standard Technical regulations for horizontal ventilation of warehouse 2020-01-21 release 2020-07-21 implementation Issued by the National Grain and Material Reserve Bureau

Contents

Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 System composition 2 5 Basic requirements 2 5.1 Requirements for warehouses and grain storage 2 5.2 Grain pile sealing and air tightness requirements 2 5.3 Basic requirements for design and installation of horizontal ventilation pipe network 3 5.4 Basic fan installation requirements 3 5.5 Requirements for grain condition detection in ventilation operations 4 6 Determination of process parameters 4 6.1 Unit ventilation 4 6.2 Ventilation per unit area of grain heap 4 6.3 Total ventilation 4 6.4 Wind speed 4 6.5 System resistance 4 6.6 Path ratio 4 6.7 Spacing of branch ducts 4 7 Operating conditions 5 7.1 Cooling and ventilation 5 7.2 High-moisture grain precipitation and ventilation 5 8 Operation and management 6 8.1 Preparation before ventilation 6 8.2 Ventilation facility preparation 6 8.3 Safety inspection before ventilation 6 8.4 Management and maintenance 6 8.5 Food condition inspection before and after ventilation and during ventilation 7 8.6 Management and maintenance after the end of ventilation 7 Appendix A (Normative Appendix) Calculation Method of Process Parameters of Lateral Ventilation System 8 Appendix B (informative appendix) Method for determining the parameters of grain ventilation conditions 11 Appendix C (Informative Appendix) Safety Checklist for Operation and Use of Horizontal Ventilation System of Bungalow 20

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by the National Grain and Material Reserve Bureau. This standard is under the jurisdiction of the National Grain and Oil Standardization Technical Committee (SAC/TC270). This standard was drafted by. Scientific Research Institute of National Grain and Material Reserve Bureau, International Trade Engineering Design Institute, Zhejiang Grain Reserve Management Company, Liaoning Ning Provincial Institute of Grain Science, Wuhan University of Light Industry, Hebei Qingyuan National Grain Reserve, Southwest Suburb Grain Collection and Storage, Henan Future Machinery Electric Engineering Co., Ltd. The main drafters of this standard. Li Fujun, Zhao Huiyi, Shi Tianyu, Wei Lei, Cao Yang, Wu Zidan, Qiu Ping, Li Xingjun, Yu Lei, Huang Zhijun, Li Yong, Gao Binbin, Cao Yi, Shu Zaixi, Jin Jiande, Ji Zhenjiang, Gao Yushu. Technical regulations for horizontal ventilation of warehouse

1 Scope

This standard specifies the terms and definitions, system composition, basic requirements, process parameters, operating conditions, and operations of horizontal ventilation technology for warehouses And management etc. This standard applies to the horizontal ventilation of bulk warehouses with a span of no more than 27m.

2 Normative references

The following documents are essential for the application of this document. For dated references, only the dated version applies to this article Pieces. For the cited documents without date, the latest version (including all amendments) applies to this document. GB/T 25229-2010 Airtightness requirements for grain and oil storage cottages GB/T 29890 Technical Specification for Grain and Oil Storage GB 50320 Design Specification for Grain Storehouse JB8523 explosion-proof ventilator technical conditions LS/T 1201 Phosphine Circulation Fumigation Technical Regulations LS/T 1202-2002 Technical regulations for ventilation of grain storage machinery

3 Terms and definitions

The following terms and definitions apply to this document. 3.1 Bungalow warehouse horizontal ventilationtransverse ventilation for stored graininwarehouse Use the suction fan installed on the vent on the side of the warehouse, through the horizontal ventilation pipe network to make the air flow from the vent on the side opposite the warehouse Inhale and laterally pass through the film-covered grain pile and discharge it from the fan, thereby changing the gas state parameters in the grain pile and adjusting the temperature and humidity of the grain pile Etc., to achieve a safe way to store grain or improve the quality of grain storage processing technology. 3.2 Airflowrateperunitareaofgrain The amount of air passing through a unit area in a direction perpendicular to the ventilation airflow per unit time, also known as the apparent wind speed, is expressed by a V meter, and the unit is m3 / (s · m2) or m/s. 3.3 Unit ventilation airflowratepertonofgrain The volume of air passing through the unit mass of grain per unit of time is denoted by q and the unit is m3/(h · t). Note. Rewrite LS/T 1202-2002, definition 3.2. 3.4 Total air quantity The total volume of air passing through the lateral ventilation system per unit time, expressed as Q total, in m3/h. Note. Rewrite LS/T 1202-2002, definition 3.3.