US$1159.00 ยท In stock Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1327-2011: Program of Pattern Evaluation of Ion Meters Status: Valid JJF 1327: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1327-2011 | English | 1159 |
Add to Cart
|
7 days [Need to translate]
|
Program of Pattern Evaluation of Ion Meters
| Valid |
JJF 1327-2011
|
JJF 1327-1990 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
(0.1 to 30 watts of laser power reference operating technical specifications)
| Obsolete |
JJF 1327-1990
|
PDF similar to JJF 1327-2011
Basic data Standard ID | JJF 1327-2011 (JJF1327-2011) | Description (Translated English) | Program of Pattern Evaluation of Ion Meters | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A61 | Classification of International Standard | 17.020 | Word Count Estimation | 50,510 | Date of Issue | 2011-11-30 | Date of Implementation | 2012-03-01 | Quoted Standard | JJG 757-2007; GB 4793.1-2007; GB/T 11606-2007 | Regulation (derived from) | State Administration of Quality Supervision, Inspection and Quarantine No. 202 of 2011 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to measurement of the electrode potential of the ion in solution ion activity meter type evaluation. |
JJF 1327-2011: Program of Pattern Evaluation of Ion Meters---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Program of Pattern Evaluation of Ion Meters
People's Republic of China National Metrology Technical Specifications
Ion meter type evaluation outline
Issued on. 2011-11-30
2012-03-01 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Ion meter type evaluation outline
Prog
This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on November 30, 2011, and from
From March 1, 2012 into effect.
Focal point. the National Technical Committee stoichiometric physical
Drafting units. China Testing Technology Research Institute
YIMT test
This specification stoichiometric commissioned National Technical Committee is responsible for the physical interpretation
The main drafters of this specification.
Zhang Yi (China Testing Technology Research Institute)
Shao Zhixin (China Testing Technology Research Institute)
Yuan Li (China Testing Technology Research Institute)
Zhang Yan (YIMT test)
table of Contents
1 Scope (1)
2. References (1)
3 Overview (1)
4 legal management requirements (1)
4.1 Units of measurement requirements (1)
4.2 accuracy requirements (1)
4.3 legal metrology requirements for marking and identification of measuring instruments (1)
4.4 offers the review of technical documents and test prototypes (2)
5 measurement requirements (2)
5.1 basic error of electronic unit (2)
5.2 Measurement repeatability electronic unit (2)
5.3 input current (2)
5.4 Input impedance (2)
5.5 Temperature compensation error (2)
5.6 Temperature measurement error (2)
5.7 output error (2)
5.8 Stability (3)
5.9 Effect of the supply voltage (3)
5.10 Ambient Temperature Effect (3)
5.11 The basic error of the instrument (3)
5.12 instrument measurement repeatability (3)
6 General Requirements (4)
6.1 Rated operating conditions (4)
6.2 appearance and initial inspection (4)
6.3 electrical safety requirements (4)
6.4 slope regulator range (5)
6.5 Equipotential regulator adjustment range (5)
6.6 Location regulator adjustment range (5)
6.7 Climate requirements (5)
6.8 Mechanical Environmental Requirements (5)
7 type evaluation item list (5)
Test conditions and test methods 8 projects (7)
8.1 Legal Requirements Management (7)
8.2 Rated operating conditions, appearance and initial inspection (7)
8.3 Electrical Safety Requirements (7)
8.4 metrological requirements (8)
8.5 General Requirements (18)
9 type evaluation and determination of the results (21)
10 original record format type evaluation (22)
Appendix A theoretical slope value of the electrode potential (23)
Appendix B shows the input level and activity value conversion table (25)
Appendix C input potential activity with the theoretical value table (27)
Appendix D Example test solution prepared by standard methods (28)
Appendix E ion meter pattern evaluation reference the original record format (32)
Ion meter type evaluation outline
1 Scope
This type of evaluation outline is applied to the electrode potential measurement of ion activity in solution ion gauge type evaluation.
2. References
JJG757-2007 ion meter
GB 4793.1-2007 measurement, control and laboratory safety requirements for electrical equipment - Part 1. General
Claim
GB/T 11606-2007 analytical instruments environmental test methods
This outline document above for applications is essential. For cited documents with dates, only undated
Versions apply to this outline. Anyone who does not dated reference documents, the latest edition (including all amendments) fitness
Used in this outline.
3 Overview
Ion meter is a device for measuring ion activity in solution electrochemical analytical instruments. Ion meter and measured mainly by the electric meter
The amount of the electrode composed of two parts. Electricity meter by the impedance converter, the potential of the amplifier, regulator and display components function measured
Electrodes include ion selective electrode and reference electrode. Ion-selective electrodes ion activity in the solution is converted to potential root
According to the Nernst equation obtained ion activity in solution. When measured by the ion activity of ions in solution, they are by comparison
Measurement, first by measuring the standard solution, ion-selective electrode and reference electrode electromotive force of ions
Meter calibration, and then use the same electrical measuring test solution, the electromotive force can be directly displayed as potential
(MV) value can also be displayed as ion activity (pX) value or concentration (mol/L, g/L, mol/electric meter after conversion
kg) value.
4 legal management requirements
4.1 units of measurement requirements
Instruments should be legal units of measurement.
4.2 accuracy requirements
Accuracy of the instrument rating shall comply JJG757-2007 "ionization gauge" requirement.
4.3 legal metrological requirements for marking and measuring instruments logo
And other significant parts of the instrument panel should be marked on the nameplate or legal metrology marking and measuring instruments identified, marked, numbered
And instructions must be clear, solid and reliable.
4.3.1 legal metrology signs generally include the following.
a) measurement equipment manufacturing license logo and number (test prototype should be left corresponding position, only domestic instrument);
b) measurement equipment type approval mark and number (non-mandatory provisions of this section, may leave the corresponding experimental prototype
position).
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1327-2011_English be delivered?Answer: Upon your order, we will start to translate JJF 1327-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1327-2011_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1327-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJF 1327-2011?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1327-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|