US$1289.00 ยท In stock Delivery: <= 8 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1332-2011: Program of Pattern Evaluation of Samplers for Stack Dust Status: Valid JJF 1332: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1332-2011 | English | 1289 |
Add to Cart
|
8 days [Need to translate]
|
Program of Pattern Evaluation of Samplers for Stack Dust
| Valid |
JJF 1332-2011
|
JJF 1332-1990 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
O.T.N. of Secondary Standard for Laser Energy
| Obsolete |
JJF 1332-1990
|
PDF similar to JJF 1332-2011
Basic data Standard ID | JJF 1332-2011 (JJF1332-2011) | Description (Translated English) | Program of Pattern Evaluation of Samplers for Stack Dust | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A61 | Classification of International Standard | 17.020 | Word Count Estimation | 56,51 | Date of Issue | 2011-12-28 | Date of Implementation | 2012-03-28 | Quoted Standard | JJG 680-2007; GB/T 3768-1996; GB/T 11606-2007; HJ/T 48-1999 | Regulation (derived from) | AQSIQ Announcement No. 205 of 2011 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to sampling flow at 60 L/min or less, the exhaust flow rate range 5m/s-30m/s, determined by weighing the gas filter dust concentration of dust sampler type evaluation. |
JJF 1332-2011: Program of Pattern Evaluation of Samplers for Stack Dust---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Program of Pattern Evaluation of Samplers for Stack Dust
People's Republic of China National Metrology Technical Specifications
Dust sampler type evaluation outline
Issued on. 2011-12-28
2012-03-28 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Dust sampler type evaluation outline
Samp
This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on December 28, 2011, and from
From March 28, 2012 into effect.
Focal point. the National Technical Committee on Environment stoichiometry
Main drafting unit. Beijing Institute of Metrology detection
Participated in the drafting unit. China Institute of Metrology
Wuhan Tianhong Instrument Co., Ltd.
Qingdao Measurement and Testing
This specification technical committee commissioned by the National stoichiometric environment responsible for interpreting
The main drafters of this specification.
Chen Zhengsheng (Beijing Institute of Metrology detection)
Drafters participate.
Zhang Ge (China Institute of Metrology)
Li Hongjie (Wuhan Tianhong Instrument Co., Ltd.)
Zhao Haibo (Beijing Institute of Metrology detection)
Zhang city (Beijing Institute of Metrology detection)
Wang Ning (Wuhan Tianhong Instrument Co., Ltd.)
Xia Chun (Qingdao Measurement and Testing)
table of Contents
1 Scope (1)
2. References (1)
3 Overview (1)
Technical information and test prototype unit 4 application should be submitted (2)
4.1 Technical Information (2)
4.2 Experimental Prototype (2)
5 legal management requirements (2)
5.1 Units of measurement requirements (2)
5.2 accuracy (maximum permissible error) requirements (2)
5.3 legal metrology requirements for marking and identification of measuring instruments (2)
6 measurement requirements (3)
6.1 flow indication error (3)
6.2 Flow Stability (3)
Timing error 6.3 (3)
6.4 Temperature indication error (3)
6.5 pressure indication error (3)
6.6 Pressure zero drift (3)
6.7 constant tracking response time (3)
6.8 isokinetic attract tracking error (3)
7 General technical requirements (3)
7.1 Appearance (3)
Tightness 7.2 (3)
7.3 suction capacity (4)
7.4 Insulation resistance (4)
7.5 dielectric strength (4)
7.6 Low temperature test (4)
7.7 High Temperature Test (4)
7.8 cryogenic storage test (4)
7.9 High temperature storage test (4)
7.10 Damp heat test (4)
7.11 Crash Test (4)
7.12 Drop test (4)
7.13 adaptive voltage supply (5)
7.14 Working noise (5)
8 pattern evaluation item list (5)
9 pilot projects test method and conditions (6)
9.1 flow indication error test (6)
Flow Stability Test 9.2 (7)
9.3 timing error test (8)
9.4 Temperature indication error test (8)
9.5 pressure indication error test (9)
9.6 Zero drift pressure test (10)
9.7 constant tracking response time test (10)
9.8 isokinetic attract tracking error test (10)
9.9 appearance and energizing check (11)
9.10 tightness (11)
9.11 pumping capacity (12)
9.12 Insulation resistance (12)
9.13 Dielectric Strength (13)
9.14 Low temperature test (13)
9.15 High Temperature Test (14)
9.16 low temperature storage test (14)
9.17 high-temperature storage test (15)
9.18 Damp heat test (15)
9.19 Crash Test (16)
9.20 Drop test (16)
9.21 Supply Voltage suitability tests (17)
9.22 Working noise test (18)
10 determined the type of evaluation results (18)
Original record format in Appendix A (19)
Dust sampler type evaluation outline
1 Scope
This type of evaluation outline is applied to the sample flow within 60L/min, the exhaust gas flow rate range 5m/s ~ 30m/s,
Determination of dust sampler dust concentration in the gas filter pattern evaluation by gravimetric method.
2. References
JJG680-2007 dust sampler
GB/T 3768-1996 Determination of sound pressure of sound power levels of noise sources using an enveloping surface reflection measurements
Surface Simple Method
GB/T 11606-2007 analytical instruments environmental test methods
HJ/T 48-1999 dust sampling technology
These documents contain provisions which through reference in this syllabus constitute provisions of this outline. For dated reference documents
Member, all subsequent amendments (not including errata content) or revisions do not apply in this outline, however, encourage
Whether the latest versions of these files according to the parties that this outline agreement. For undated references the
, The latest versions apply to this outline.
3 Overview
Dust sampler is measuring flue, chimney and general dust particles by sampling the gas pipeline manner by filtration weighing method
Particulate matter concentration of the instrument.
Filter dust sampler weighing method principle is. a certain amount of dust gas through the known mass of the filter cartridge or filter dust
Particles are retained by the removal of uncombined water, according to the incremental samples before and after the filter cartridge or filter paper, calculated per unit volume of gas
The particulate mass. Mentioned below refers to filter dust sampler dust sampler weighing method.
Dust sampler type dust sampler is divided into manual and automatic type dust sampler.
Manually type dust sampler is measured in advance before sampling the temperature at the sampling point, pressure, gas flow rate and other parameters, namely,
Sample flow sampling points required when calculating dust sampler to work, you want to manually adjust the sampling flow through to
Demand flow values sampled. The structure shown in Figure 1.
Figure 1 Manually type dust sampler chart
1- sampling device; 2- pressure measuring device; 3- a temperature measuring device; 4- flow measurement and control device; 5- suction pump
Auto-type dust sampler is a measurement and control system in accordance with various sensors to detect pressure, temperature and other parameters, by
, And calculates the corresponding control signal, the control circuit adjusts the suction pump pumping capacity, to achieve the appropriate traffic. from
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1332-2011_English be delivered?Answer: Upon your order, we will start to translate JJF 1332-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 5 ~ 8 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1332-2011_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1332-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJF 1332-2011?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1332-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|