Calibration Specification for Thermometers of Clinic Autoclave
| Valid |
JJF 1308-2011
|
| JJF 1308-1990 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
O.T.N of the Cs-Ⅲ Cesium Atom Beam Time-Frequency Primary Standard
| Obsolete |
JJF 1308-1990
|
PDF similar to JJF 1308-2011
Basic data | Standard ID | JJF 1308-2011 (JJF1308-2011) | | Description (Translated English) | Calibration Specification for Thermometers of Clinic Autoclave | | Sector / Industry | Metrology & Measurement Industry Standard | | Classification of Chinese Standard | A54 | | Classification of International Standard | 17.200 | | Word Count Estimation | 14,124 | | Date of Issue | 2011-09-14 | | Date of Implementation | 2012-12-14 | | Quoted Standard | GB/T 19974-2005; GB/T 20367-2006; Ministry of Health disinfection technical specifications 2002 edition; EN 285; EN 554; HTM 2010 | | Regulation (derived from) | AQSIQ Announcement No. 134 of 2011 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | | Summary | This standard applies to saturated steam heat sterilization equipment for medical thermometer calibration of measuring performance. Other heat sterilization equipment thermometer calibration can refer to this specification. |
JJF 1308-2011: Calibration Specification for Thermometers of Clinic Autoclave---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Thermometers of Clinic Autoclave
People's Republic of China National Metrology Technical Specifications
Medical sterilization equipment thermal thermometer calibration specifications
Issued on. 2011-09-14
2011-12-14 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Heat sterilization of medical equipment Thermometer
Calibration Specification
This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on September 14, 2011, and from
From December 14, 2011 into effect.
Focal point. the National Technical Committee of temperature measurement
The main drafting units. China Institute of Metrology
Participated in the drafting unit. Hebei Institute of Metrology
Chongqing Institute of Measurement
This specification temperature measured by the National Technical Committee is responsible for interpretation
The main drafters of this specification.
Zhang Jintao (China Institute of Metrology)
Drafters participate.
Qiu Ping (China Institute of Metrology)
Jin Zhijun (China Institute of Metrology)
Liu Hongyan (Hebei Institute of Metrology)
Liu Ying Ying (Chongqing Institute of Measurement)
table of Contents
1 Scope (1)
2. Referenced Documents (1)
3 Terms and Definitions (1)
4 Metrological characteristics (2)
Calibration Condition 5 (2)
5.1 environmental conditions (2)
5.2 load condition (2)
5.3 Measurement Standards (2)
6 calibration items and calibration methods (2)
6.1 calibration items (2)
6.2 Calibration Method (2)
Expression 7 Calibration results (3)
7.1 Calibration Results (3)
7.2 calibration certificate contents (3)
8 Recalibration interval (4)
Appendix A shows the value of error measurement uncertainty estimation methods (recommended) (5)
Appendix B sterilization equipment cabin temperature distribution, cabin pressure, sterilization load internal temperature measurement method
(Recommendation) (8)
Medical sterilization equipment thermal thermometer calibration specifications
1 Scope
This instruction applies to saturated steam heat sterilization of medical equipment thermometer calibration measurement of performance. Let other moist heat sterilization
Thermometer calibration can be prepared with reference to the present specification.
2 Citations
GB/T 19974-2005 Characteristics Sterilization of health care products and medical equipment sterilization factor sterilization process
Preferences, General requirements for validation and routine control of
Validation and routine control of GB/T 20367-2006 Sterilization of health care products health care institutions moist heat sterilization
System Requirements
People's Republic of China Ministry of Health "disinfection technical specifications" (2002 edition)
EN285 steam sterilization. large-scale sterilization equipment (EN285 SteamSterilizers. Largesterilizers)
EN554 medical instrument sterilization --- validation and routine control of moist heat sterilization (EN554 Sterilizationof
medicaldevice-Validationandroutinecontrolofsterilizationbymoistheat)
HTM2010 health technology briefs 2010 (HTM2010 HealthTechnicalMemorandum2010)
When using this specification it should be noted that using the currently valid version of the documents cited.
3 Terms and Definitions
3.1 Sterilization temperature sterilizationtemperature
"Disinfection technical specifications" provides heat to kill bacteria, spores saturated steam temperature.
3.2 Sterilization equilibration time equilibrationtime
Sterilization equipment sterilization chamber temperature reaches a certain point in time over the entire sterilization load to all points are reached sterilizing temperature
Time interval.
3.3 sterilization temperature band sterilizationband
Within the sterilization holding time between sterilization temperature sterilization to the maximum allowable temperature range.
3.4 Sterilization holding time holdingtime
Sterilizer load temperature at all points remained at the length of time the sterilization temperature band.
3.5 sterilization plateau time plateautime
Sterilization equipment sterilization temperature reached a point until the end of time interval sterilization. Sterilization sterilization plateau time is balanced
Between the sum and sterilization holding time.
3.6 heat sterilization of medical equipment thermometer clinicsterilizerthermometer
Sterilization equipment configuration itself thermometer (hereinafter referred to as calibrated thermometer).
3.7 Reference thermometer referencethermometer
For calibration and testing purposes thermometer.
|