GB/T 37751.31-2019: Residual current operated circuit-breakers for household and similar use -- Part 3-1: Particular requirements for RCDs with screwless-type terminals for external copper conductors
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 37751.31-2019English264 Add to Cart 3 days [Need to translate] Residual current operated circuit-breakers for household and similar use -- Part 3-1: Particular requirements for RCDs with screwless-type terminals for external copper conductors Valid GB/T 37751.31-2019

PDF similar to GB/T 37751.31-2019


Standard similar to GB/T 37751.31-2019

GB/T 41589   GB/T 40820   GB/T 37751.32   GB/T 33346   GB/T 37751.2   GB/T 37751.33   

Basic data

Standard ID GB/T 37751.31-2019 (GB/T37751.31-2019)
Description (Translated English) Residual current operated circuit-breakers for household and similar use -- Part 3-1: Particular requirements for RCDs with screwless-type terminals for external copper conductors
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K31
Classification of International Standard 29.120.50
Word Count Estimation 14,115
Date of Issue 2019-06-04
Date of Implementation 2020-01-01
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 37751.31-2019: Residual current operated circuit-breakers for household and similar use -- Part 3-1: Particular requirements for RCDs with screwless-type terminals for external copper conductors



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Residual current operated circuit-breakers for household and similar use--Part 3-1. Particular requirements for RCDs with screwless-type terminals for external copper conductors ICS 29.120.50 K31 National Standards of People's Republic of China Residual current operated circuit breakers for household and similar purposes Part 3-1. with external copper conductors Special requirements for RCDs without threaded terminals Part 3-1. ParticularrequirementsforRCDswithscrewless-typeterminals (IEC 62873-3-1..2016, IDT) Published on.2019-06-04 2020-01-01 implementation State market supervision and administration China National Standardization Administration issued

Content

Foreword III 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Category 2 5 RCD features 2 6 logo and other product information 2 7 Standard operating conditions for use and installation 2 8 Structure and operation requirements 2 9 test 4 Reference 8

Foreword

GB/T 37751 "Residual current operated circuit breakers for household and similar purposes" is divided into the following sections. --- Part 1. Overview of independent modules and unit modules for residual current electrical standards (GB/T 37751.1); --- Part 2. Residual current electrical appliances (RCD) vocabulary (GB/T 37751.2); --- Part 3-1. Particular requirements for RCDs with non-threaded terminals to be connected to external copper conductors (GB/T 37751.31); --- Part 3-2. Particular requirements for RCDs with flat quick-connect ends (GB/T 37751.32); ---Part 3-3. Threaded terminal blocks with external untreated aluminium conductors and aluminium threaded connection to copper or aluminium conductors Special requirements for type terminal block RCD (GB/T 37751.33). This part is part 3-1 of GB/T 37751. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This section uses the translation method equivalent to IEC 62873-3-1.2016 "Residual current operated circuit breakers for household and similar purposes 3-1" Part. Special requirements for RCDs with unthreaded terminal blocks for external copper conductors. The documents of our country that have a consistent correspondence with the international documents referenced in this part are as follows. ---GB/T 16916.1-2014 Residual current operated circuit breaker (RCCB) without overcurrent protection for household and similar purposes Part 1. General rules (IEC 61008-1.2012, MOD); ---GB/T 16917.1-2014 Residual current operated circuit breaker (RCBO) with overcurrent protection for household and similar purposes Part 1. General rules (IEC 61009-1.2012, MOD); --- GB/T 37751.2-2019 Residual current operated circuit breakers for household and similar purposes - Part 2 (RCD) vocabulary (IEC 62873-2.2016, IDT). This section has made the following editorial changes. --- Deleted the original note in the first note in Chapter 1, the original note in 3.2, and the second half of the original note 2 in 9.3.2, whose content has nothing to do with China; --- Table 1 "Connectable wires" Note in the reference file "ASTMB172-01a" is incorrect, changed to "ASTMB172-17", the same It is modified accordingly in the reference. This part was proposed by China Electrical Equipment Industry Association. This part is under the jurisdiction of the National Low Voltage Electrical Appliance Standardization Technical Committee (SAC/TC189). This section drafted by. Shanghai Electric Apparatus Research Institute, Zhejiang Zhengtai Electric Co., Ltd., Zhongshan Kaipu Electric Co., Ltd., Shi Ned Electric (China) Co., Ltd. Shanghai Branch. The main drafters of this section. Zhang Lili, Li Renjie, Zhu Jun, Zou Jianhua, Zhou Lei. Residual current operated circuit breakers for household and similar purposes Part 3-1. with external copper conductors Special requirements for RCDs without threaded terminals

1 Scope

This part of GB/T 37751 is applicable to RCDs with unthreaded terminals with rated current not exceeding 20A. The terminal blocks are mainly used to connect untreated (see 3.5) copper conductors with a cross-sectional area of 4 mm2. This section cannot be used alone. For RCDs with unthreaded terminals, this part and the RCD product standard (IEC 61008- 1 or IEC 61009-1) used together. In this section, the non-threaded terminal block is called a terminal block, and the copper wire is called a wire.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. IEC 61008-1 Residual current operated circuit-breakers (RCCB) without overcurrent protection for household and similar purposes - Part 1. 1 General rule [Residualcurrentoperatedcircuit-breakers without integralovercurrentprotectionfor Householdandsimilaruses(RCCBs)-Part 1.Generalrules] IEC 61009-1 Residual current operated circuit breakers (RCBO) with overcurrent protection for household and similar purposes - Part 1. General Rule [Residualcurrentoperatedcircuit-breakerswithintegralovercurrentprotectionforhouseholdand Similaruses(RCBOs)-Part 1.Generalrules] Residual current operated circuit breakers for household and similar purposes - Part 2. Residual current electrical appliances (RCD) vocabulary [Re- Sidualcurrentoperatedcircuit-breakersforhouseholdandsimilaruses-Part 2.Residualcurrentde- Vices(RCDs)-Vocabulary]

3 Terms and definitions

The following terms and definitions as defined by IEC 62873-2 apply to this document. 3.1 Clamping unit clampingunits The components necessary for mechanical clamping and electrical connection of the conductors in the terminals, including the components necessary to ensure normal contact pressure. 3.2 Universal terminal block universalterminal Terminal block for connecting and removing all type conductors (hard and soft). 3.3 Non-universal terminal block non-universalterminal Used only to connect and disconnect certain wires [for example, only for hard solid wires or terminals for hard (solid or stranded) wires only].

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 37751.31-2019_English be delivered?

Answer: Upon your order, we will start to translate GB/T 37751.31-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 37751.31-2019_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 37751.31-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.