US$199.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 10760.1-2017: Generator of small wind turbines -- Part 1: Technical condition Status: Valid GB/T 10760.1: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 10760.1-2017 | English | 199 |
Add to Cart
|
3 days [Need to translate]
|
Generator of small wind turbines -- Part 1: Technical condition
| Valid |
GB/T 10760.1-2017
|
| GB/T 10760.1-2003 | English | 319 |
Add to Cart
|
3 days [Need to translate]
|
Generator of off grid wind turbines generator system -- Part 1: Technical condition
| Obsolete |
GB/T 10760.1-2003
|
| GB/T 10760.1-1989 | English | 359 |
Add to Cart
|
3 days [Need to translate]
|
Specification for small wind generators
| Obsolete |
GB/T 10760.1-1989
|
PDF similar to GB/T 10760.1-2017
Basic data | Standard ID | GB/T 10760.1-2017 (GB/T10760.1-2017) | | Description (Translated English) | Generator of small wind turbines -- Part 1: Technical condition | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | F11 | | Classification of International Standard | 27.180 | | Word Count Estimation | 10,127 | | Date of Issue | 2017-10-14 | | Date of Implementation | 2018-05-01 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
GB/T 10760.1-2017: Generator of small wind turbines -- Part 1: Technical condition---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Generator of small wind turbines - Part 1. Technical condition
ICS 27.180
F11
National Standards of People's Republic of China
Replacing GB/T 10760.1-2003
Small wind turbine generator
Part 1. Technical conditions
Part 1.Technicalcondition
2017-10-14 Published
2018-05-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
China National Standardization Administration released
Foreword
GB/T 10760 "small wind turbine generator" is divided into the following two parts.
--- Part 1. Technical conditions;
--- Part 2. Test methods.
This section GB/T 10760 Part 1.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This Part replaces GB/T 10760.1-2003 "Off-grid wind turbine generator Part 1 Technical conditions." versus
GB/T 10760.1-2003 compared to editorial changes in addition to the main technical changes are as follows.
--- Expand the scope of this section;
--- Standardized reference documents and made a readjustment;
--- Expanded generator rated power level;
--- Remove the generator rated power and rated speed, rated voltage table, increase the rated voltage level;
--- Increased direct drive generator rated power, rated speed corresponding to the recommended table;
--- Modify the generator working speed range and requirements;
--- Modify the generator overload requirements;
--- Modify the generator efficiency table;
--- Modify the ability of the generator to withstand speeding under no load;
--- Modify the generator insulation level requirements;
--- Modify the generator bearings allow temperature requirements;
--- Modify the generator insulation resistance requirements after damp heat test;
--- Modify the different types of windings turn-on voltage test method;
--- Modify the generator no-load starting torque requirements;
--- Modify the generator safety requirements;
--- Increased generator vibration limit requirements;
--- Increased generator noise limit requirements;
--- Updated inspection rules.
This part is proposed by China Machinery Industry Federation.
This part of the National Wind Machinery Standardization Technical Committee (SAC/TC50) centralized.
This part of the drafting unit.Ningbo Jinlang New Energy Technology Co., Ltd., China Agricultural Mechanization Research Institute Hohhot Branch,
Hefei People Power Co., Ltd., Guangzhou Red Eagle Energy Technology Co., Ltd., Hohhot Boyang Renewable Energy Co., Ltd.,
Shanghai Zhiyuan Green Energy Co., Ltd., Aohuang Detection Technology Services (Shanghai) Co., Ltd., State Grid Zhejiang Xiangshan County Power Company.
The main drafters of this section. Wang Yiming, Zhang Tianci, Dong Wenbin, Zhang Weimin, Wu Yougang, Yang Bin, Yu Wei, Huang Fei, Wang Weifu.
This section was first released in April.2003, this is the first revision.
Small wind turbine generator
Part 1. Technical conditions
1 Scope
GB/T 10760 provisions of this part of a small wind turbine generator (hereinafter referred to as "generator") General technical conditions.
This section applies to 0.1kW ~ 100kW wind turbine generator.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all revisions) applies to this document.
GB/T 191 Packaging - Pictorial signs
GB/T 755 Rotating motor quotas and performance
GB/T 997 rotary motor structure type, installation type and junction box location classification (IM code)
GB/T 1993 rotary motor cooling method
GB/T 4942.1 rotary motor overall structure of the protection level (IP code) classification
GB 5226.1 Safety of machinery - Electrical machinery and electrical equipment - Part 1. General specifications
GB/T 9969 Industrial Products Manual General
GB/T 10068 Shaft center height of 56mm and above the motor vibration and vibration measurement, assessment and limits
GB/T 10069.3 rotary motor noise measurement methods and limits - Part 3 noise limits
GB/T 10760.2 Small generators for wind turbines - Part 2. Test methods
GB/T 12665 motor under normal conditions of use damp heat test requirements
GB/T 17646 small wind turbine
GB/T 19068.2 small wind turbine generator - Part 2. Test methods
GB/T 22719.1 alternating current low-voltage motors interspersed winding inter-turn insulation Part 1. Test methods
GB/T 22719.2 alternating current low-voltage motors scattered windings inter-turn insulation Part 2. Test limits
Test methods and limits for turn - to - turn insulation of molded low - voltage windings of JB/T 5811
3 Terms and definitions
GB/T 755, GB/T 17646 defined terms and definitions apply to this document.
4 type, the basic parameters
4.1 type
The type of generator is a three-phase AC synchronous generator.
4.2 Rated power
The generator shall be manufactured (kW) at the following rated power.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 10760.1-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 10760.1-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 10760.1-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 10760.1-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 10760.1-2017?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 10760.1-2017 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|