GB/T 10066.2-2019: Test methods for electroheating and electromagnetic processing installations -- Part 2: Direct arc furnaces
Status: Valid

GB/T 10066.2: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 10066.2-2019English344 Add to Cart 4 days [Need to translate] Test methods for electroheating and electromagnetic processing installations -- Part 2: Direct arc furnaces Valid GB/T 10066.2-2019
GB/T 10066.2-2004English639 Add to Cart 5 days [Need to translate] Electric equipment test methods -- Part 2: induction channel furnace Obsolete GB/T 10066.2-2004
GB/T 10066.2-1988English239 Add to Cart 2 days [Need to translate] Test methods for electroheat installations--Induction channel furnaces Obsolete GB/T 10066.2-1988

PDF similar to GB/T 10066.2-2019


Standard similar to GB/T 10066.2-2019

GB/T 37752.1   GB/T 5959.41   GB/T 31137   GB/T 10066.1   GB/T 10066.6   GB/T 10066.11   

Basic data

Standard ID GB/T 10066.2-2019 (GB/T10066.2-2019)
Description (Translated English) Test methods for electroheating and electromagnetic processing installations -- Part 2: Direct arc furnaces
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K61
Classification of International Standard 25.180.10
Word Count Estimation 18,168
Date of Issue 2019-08-30
Date of Implementation 2020-03-01
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 10066.2-2019: Test methods for electroheating and electromagnetic processing installations -- Part 2: Direct arc furnaces


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Test methods for electroheating and electromagnetic processing installations - Part 2. Direct arc furnaces ICS 25.180.10 K61 National Standards of People's Republic of China Replace GB/T 10066.10-2005 Test method for electrothermal and electromagnetic treatment devices Part 2. Direct electric arc furnace Part 2.Directarcfurnaces (IEC 60676.2011, Industrial electroheatingequipment-Testmethodsfor Directarcfurnaces, IDT) Published on.2019-08-30 2020-03-01 implementation State market supervision and administration China National Standardization Administration issued

Content

Foreword III 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Characteristics of the electric arc furnace system 4 4.1 General Terms 4 4.2 Electric assembly of electric arc furnace 4 4.3 Furnace structure 5 4.4 Water cooling 5 5 General test conditions for test type and its performance 5 5.1 General requirements 5 5.2 Cold and hot test items 5 6 Technical Test 6 6.1 Electrical insulation of high current systems 6 6.2 Cooling water system 6 6.3 Electrode moving speed 6 6.4 Short circuit test procedure 6 6.5 Main characteristics during operation of the electric arc furnace 10 6.6 Electrode consumption 11 6.7 Phase sequence 11 6.8 Electric Arc Furnace - Rated Capacity 11 Reference 12

Foreword

There are 12 parts in GB/T 10066. --- GB/T 10066.1 Test methods for electrothermal and electromagnetic treatment systems - Part 1. General part; GB/T 10066.2 Test methods for electrothermal and electromagnetic treatment systems - Part 2. Direct electric arc furnace; --- GB/T 10066.3 Test methods for electroheating devices - Part 3. s. --- GB/T 10066.31 Test methods for electrothermal and electromagnetic treatment devices - Part 31 --- GB/T 10066.4 Test methods for electroheating equipment - Part 4. Indirect resistance furnaces; GB -T 10066.5 Test methods for electroheating devices - Part 5. Electrophysical and electro Test methods of electroheat and electromagnetic treatment systems - Part 6. Output power of industrial microwave heating devices test methods; GB/T 10066.7 Test methods for electroheating devices - Part 7. Electrothermal devices with electron guns; GB/T 10066.8 Test methods for electroheating devices - Part 8. Electroslag remelting furnaces; GB/T 10066.9 Test methods for electroheating devices - Part 9. Determination of output power of high-frequency medium heating devices; GB/T 10066.11 Test methods for electric heating devices - Part 11. Submerged arc furnaces; --- GB/T 10066.12 Test methods for electric heating devices - Part 12. Infrared heating devices. This part is the second part of GB/T 10066. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This part replaces GB/T 10066.10-2005 "Test methods for electric heating devices - Part 10. Direct electric arc furnace", and The main technical changes compared with GB/T 10066.10-2005 are as follows. --- The definition of the furnace type is more clear; --- Updated and supplemented with normative references and terminology; --- Added Chapter 4 "Characteristics of Electric Arc Furnace System", including general terms, electrical assembly of electric arc furnace, furnace structure, water cooling 4; --- Added consideration of safety standards in the "General Requirements" of Chapter 5, "General Test Conditions for Types of Tests and Their Performance", SVC, power fluctuations, measurement points, measurement equipment requirements; ---Modified the contents of the "Technical Test" (see Chapter 6, Chapter 5 of the.2005 edition); --- Simplify the wiring diagram of resistance and reactance measurement (see Figure 1,.2005, Figure 1, Figure 2 and Figure 3). This section uses the translation method equivalent to IEC 60676.2011 "Test methods for direct electric arc furnaces for industrial electric heating equipment". The documents of our country that have a consistent correspondence with the international documents referenced in this part are as follows. --- GB/T 5959.1-2019 Safety of electrothermal and electromagnetic treatment systems - Part 1. General requirements (IEC 60519-1.2015, IDT) Safety of electric heating installations - Part 2. Particular requirements for electric arc furnace installations (IEC 60519-4. 2006, IDT) GB/T 10066.1-2019 Test methods for electrothermal and electromagnetic treatment systems - Part 1. General part (IEC 60398. 2015, MOD) This section has made the following editorial changes. --- The standard name was changed to "Test method for electrothermal and electromagnetic treatment devices - Part 2. Direct electric arc furnace"; --- Delete the 3.6 (electric arc furnace) capacity in the unit description of the note "is metric units or British tons according to the pre-agreed"; ---3.21 units were changed to "MVA"; --- 6.2 units are modified to "Pa". This part was proposed by China Electrical Equipment Industry Association. This part is under the jurisdiction of the National Technical Committee for Standardization of Industrial Electric Heating Equipment (SAC/TC121). This section drafted by. Xi'an Electric Furnace Research Institute Co., Ltd., Suzhou Zhenwu Electric Furnace Co., Ltd., Shaanxi Hongxinyuan Metallurgical Equipment Industry Limited company, Xi'an Zhongye New Materials Co., Ltd., National Electric Furnace Quality Supervision and Inspection Center. The main drafters of this section. Yu Weijiang, Li Wei, Zhu Xingfa, Yan Xianbin, Tian Hangliang, Qi Jun, Zhang Yongwu, Huang Kuigang, Yang Jia. The previous versions of the standards replaced by this section are. ---GB/T 6542-1986; ---GB/T 10066.10-2005. Test method for electrothermal and electromagnetic treatment devices Part 2. Direct electric arc furnace

1 Scope

This part of GB/T 10066 specifies the test procedures, conditions and methods for electric arc furnace (EAF), based on which the capacity is determined. Main parameters and main operating characteristics of AC electric arc furnace (EAFac) or DC electric arc furnace (EAFdc) above 500kg/furnace. The electric arc furnace technology is also suitable for this type of furnace, ie the liquid metal in the furnace is kept at a high temperature or superheated to the pouring temperature [eg a steel ladle using AC) Furnace (LF)]. Test methods for certain special equipment, such as DC arc furnace controlled rectifiers, are specified in IEC 60146-1-1. The test method for the submerged arc furnace (SAF) is specified in IEC 60683.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. IEC 60398.1999 General test methods for industrial electrothermal installations (Industrial electroheatinginstalations-General Testmethods) Safety of electroheat installations - Part 1. General requirements (Safetyinelectroheatinginstalations- Part 1. Generalrequirements) Safety of electroheat installations - Part 4. Particular requirements for electric arc furnace installations (Safetyinelectroheatinstal- lations-Part 4.Particularrequirementsforarcfurnaceinstalations)

3 Terms and definitions

The following terms and definitions as defined in IEC 60519-1.2010 apply to this document. Note. The general definition refers to IEC 60050 International Electrotechnical Vocabulary. Terms related to industrial heating are specified in IEC 60050-841. 3.1 Active power activepower The average value of the instantaneous power p (kW) in the cycle time T(h) in the periodic state. P= T∫ Pdt Note. The active power instantaneous value (root mean square value) can be measured at any time, including all phases. [IEC 60050-131.2002, 131-11-42, revised] 3.2 Apparent power apparentpower The rated power (MVA) of the transformer that supplies the electric arc furnace. S= 3UI

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 10066.2-2019_English be delivered?

Answer: Upon your order, we will start to translate GB/T 10066.2-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 10066.2-2019_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 10066.2-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 10066.2-2019?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 10066.2-2019 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.