GB/T 6829-2024 English PDF

US$1054.00 · In stock
Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 6829-2024: General safety requirements for residual current operated protective devices
Status: Valid

GB/T 6829: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 6829-2024English1054 Add to Cart 7 days [Need to translate] General safety requirements for residual current operated protective devices Valid GB/T 6829-2024
GB/T 6829-2017English1439 Add to Cart 7 days [Need to translate] General requirements for residual current operated protective devices Obsolete GB/T 6829-2017
GB 6829-1995EnglishRFQ ASK 11 days [Need to translate] General requirements for residual current operated protective devices Obsolete GB 6829-1995
GB 6829-1986EnglishRFQ ASK 3 days [Need to translate] Residual current operated protective devices Obsolete GB 6829-1986

PDF similar to GB/T 6829-2024


Standard similar to GB/T 6829-2024

GB/T 7251.2   GB/T 7251.1   GB 7251.12   

Basic data

Standard ID GB/T 6829-2024 (GB/T6829-2024)
Description (Translated English) General safety requirements for residual current operated protective devices
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K31
Word Count Estimation 52,586
Date of Issue 2024-05-28
Date of Implementation 2024-12-01
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 6829-2024: General safety requirements for residual current operated protective devices

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 29.120.50 CCSK31 National Standards of People's Republic of China Replaces GB/T 6829-2017 General safety requirements for residual current operated protective devices (IEC 60755.2017, IDT) Released on 2024-05-28 2024-12-01 implementation State Administration for Market Regulation The National Standardization Administration issued

Table of Contents

Preface III Introduction IV 1 Scope 1 2 Normative references 1 3 Terms and definitions 3 4 Categories 3 4.1 According to the action mode, 3 4.2 According to the device type 3 4.3 Classification according to the possibility of adjusting the residual operating current 4.4 When the residual current contains a DC component, the following three types of 4.5 Delay division according to (when residual current greater than IΔn occurs) 3 4.6 Classification based on protection against external influences 4.7 According to the installation method 4.8 According to the wiring method 4.9 Classification by terminal type 4.10 Classification according to the number of poles and current loops 4.11 Classification by instantaneous tripping current 4.12 Classification based on I2t characteristics 5 4.13 According to overcurrent protection 5 4.14 According to the structural type 5 4.15 According to the intended use 5 4.16 According to the ambient air temperature range 5 5 Characteristics of RCD 5 5.1 Feature Overview 5 5.2 Rated capacity and other characteristics 6 5.3 Standard values and preferred values 8 5.4 Coordination with short-circuit protection devices (SCPD) 9 6 Logo and other product information 9 6.1 Marking and information for RCDs classified according to 4.15.1 9 6.2 Marking and information for RCDs classified according to 4.15.2 and 4.15.3 10 7 Standard working conditions for use and installation 10 7.1 Preferred application range, reference values of influencing quantities/factors and related test tolerances 10 7.2 Installation conditions 10 7.3 Pollution degree 11 7.4 Additional standard conditions for use and installation when RCDs are incorporated into or built into equipment 11 8 Structural and operational requirements 11 8.1 Mechanical Design 11 8.2 Protection against electric shock 13 8.3 Dielectric properties and isolation capabilities 14 8.4 Temperature rise 14 8.5 Action Characteristics 14 8.6 Mechanical and electrical life 15 8.7 Performance under short-circuit current 16 8.8 Mechanical shock and impact resistance 16 8.9 Heat resistance 16 8.10 Resistance to abnormal heat and flame retardancy 16 8.11 Test equipment 16 8.12 Requirements for RCDs in the event of power failure 16 8.13 Performance of RCD in case of main circuit overcurrent 16 8.14 Performance of RCDs in the presence of surge currents caused by impulse voltage 16 8.15 Empty 17 8.16 Reliability 17 8.17 Electromagnetic Compatibility (EMC) 17 8.18 Transient Overvoltage Withstand (TOV) 17 9 Drafting of test clauses for RCD product standards and test clauses for RCDs contained in or embedded in equipment 17 9.1 General requirements 17 9.2 Action Characteristics 18 9.3 Electrical life test 22 9.4 Performance test of RCD under short-circuit conditions 22 9.5 Verification of free tripping mechanism 23 9.6 Verification of the operation of the test device 23 9.7 Verifying the performance of RCD under surge current generated by impulse voltage 24 9.8 Reliability test 25 9.9 Electromagnetic compatibility test (EMC) 25 Appendix A (Informative) Recommended circuit diagram for short-circuit test 36 Appendix B (Informative) Possible load current and fault current 39 Appendix C (Informative) Correspondence between clauses and modules 42 Appendix D (Informative) Relationship with product standards 44 Reference 45

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents" Drafting. This document replaces GB/T 6829-2017 "General requirements for residual current operated protective devices (RCD)" and is compatible with GB/T 6829-2017 Compared with the previous version, in addition to structural adjustments and editorial changes, the main technical changes are as follows. --- Deleted the voltage limit of 440V in the range (see Chapter 1 of the.2017 edition); --- Changed the terms and definitions (see Chapter 3, Chapter 3 of the.2017 edition); --- Changed the content of "based on the mode of action" (see 4.1, 4.1 of the.2017 edition); --- The classification has been added with "based on protection against external influences", "based on installation method", "based on wiring method" and "based on intended use". points” (see 4.6, 4.7, 4.8 and 4.15); --- "Based on whether there is automatic reclosing" has been deleted from the classification (see 4.11 of the.2017 edition); --- For equipment combined with RCD or embedded with RCD, product marking requirements, mechanical design requirements and action characteristics requirements are added (see 6.2, 8.1.1.2 and 8.5.4); --- Deleted the additional requirements for RCDs whose operating functions are related to the power supply voltage (see 8.3.3 of the.2017 edition); --- Added transient overvoltage (TOV) performance requirements (see 8.18); --- Added "Drafting of test clauses for RCD product standards and test clauses for RCD contained or embedded in equipment" (see Chapter 9); --- Added the relationship with product standards and gave the products related to this document (see Appendix D). This document is equivalent to IEC 60755.2017 "General safety requirements for residual current operated protective devices". The following minimal editorial changes were made to this document. --- Add Note 3 to the scope, and introduce informative Appendix C; --- Move the informative reference IEC 60068-3-4 from Chapter 2 to the references. Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document was proposed by the China Electrical Equipment Industry Association. This document is under the jurisdiction of the National Technical Committee for Low Voltage Electrical Appliances Standardization (SAC/TC189). This document was drafted by. Shanghai Electric Science Research Institute, Changshu Switch Manufacturing Co., Ltd. (formerly Changshu Switch Factory), Shanghai Siemens Circuit Protection Systems Co., Ltd., Zhejiang Chint Electric Co., Ltd., Zhejiang Tianzheng Electric Co., Ltd., Qingdao Dingxin Communication Co., Ltd. Company, Shanghai Liangxin Electric Co., Ltd., Suzhou Yieryi Electric Manufacturing Co., Ltd., Zhongshan Kaipu Electric Co., Ltd., Panasonic Information Instrument (Shanghai) Co., Ltd., Jiangsu Daquan Kaifan Switchgear Co., Ltd., Eaton Electric Co., Ltd., Beijing ABB Low Voltage Electrical Co., Ltd. Garcia Electronics Co., Ltd., Jiangsu Luokai Electromechanical Co., Ltd., Shanghai Chint Intelligent Technology Co., Ltd., Xinchi Electric Group Co., Ltd., Wenzhou Huajia Electric Co., Ltd., Xiamen Zhentaicheng Technology Co., Ltd., Guangzhou Baiyun Electric Equipment Co., Ltd., Shanxi Guojian Engineering Inspection and Testing Co., Ltd., Wasion Energy Technology Co., Ltd., Hangzhou Electric Power Equipment Manufacturing Co., Ltd. Yuhang Qunlicheng Electric Manufacturing Branch, Guizhou Taiyong Changzheng Technology Co., Ltd. The main drafters of this document are. Yin Tianwen, Wang Yuxuan, Guan Ruiliang, Chen Jia, Si Yingge, Yang Hongyi, Li Fangwei, Wei Xi, Li Chengli, Yu Xingjin, Chen Yijie, Li Tao, Wang Xingyang, Zhang Jun, Wu Manhuai, Tan Jianping, Zhou Changqing, Xia Chuyang, Huang Guangfa, Cai Chongsheng, Zeng Bo, Zhu Wenjuan, Tan Sai, Miao Yufeng, Zhang Zhiyu. The previous versions of this document and the documents it replaces are as follows. --- First issued as GB 6829-1986 in 1986 and first revised in.1995; --- Revised for the second time in.2008, the number was adjusted to GB /Z 6829-2008; --- Revised for the third time in.2017, the number was adjusted to GB/T 6829-2017; ---This is the fourth revision.

Introduction

This document is intended primarily for technical committees preparing residual current units, power supplies and other components for use in providing protection according to IEC 60364 (all parts). Use when the energy or electrical appliance is in compliance. There are two basic types of protection against electric shock hazards. fault protection (indirect contact) and basic protection (direct contact). Fault protection means that the appliance is used to prevent the continuous dangerous voltage on the accessible metal parts of the electrical device in the event of a ground fault. Under these circumstances, these grounded metal parts will become electrically charged. In this case, the danger comes from the user coming into contact with a grounded metal part which itself is in contact with a live conductive part. contact with live conductive parts rather than direct contact with them. The main function or basic function of residual current operated protective devices is to provide fault protection. The operating current does not exceed 30mA. It can also provide additional protection for people or livestock who are in direct contact with live conductors when other protective measures fail. Protect. Therefore, the operating characteristics given in this document are based on such requirements, which themselves are based on IEC 60479-1 and IEC 60479-2. Information included. The residual current operated protective device with a rated residual operating current not exceeding 300mA can also respond to long-term continuous ground fault current (not Provide protection against fire hazards caused by overcurrent protection devices. General safety requirements for residual current operated protective devices

1 Scope

This document specifies the minimum standards for the drafting of standards for residual current operated protective devices (hereinafter referred to as "residual current protective devices, RCDs"). Requirements, recommendations and information. This document applies to any electrical appliance providing residual current protection, primarily intended to prevent risk of electric shock. NOTE 1 This document does not include residual current monitors (RCMs) in accordance with IEC 62020, which are intended to monitor electrical installations rather than provide protection and cannot be considered Similar to or equal to RCD. NOTE 2 RCDs for DC systems are under consideration. Note 3.The correspondence between the clauses and modules of this document is shown in Appendix C. Note 4.The connection between RCD product standards and this document is shown in Appendix D. This document is mainly used as a reference for drafting product safety standards for "RCD" or "Residual Current Devices". These devices are used for general It is also installed or embedded in the device. This document is also used as a reference to specify the design requirements and applicable test procedures for RCDs installed or embedded in equipment. This common safety publication is intended for technical committees to prepare documents based on the principles specified in IEC Guide 104 and ISO /IEC Guide 51. It is used when formulating standards and is not intended for use by manufacturers or certification bodies. It is the responsibility of the technical committee to use common safety publications when preparing publications, where applicable. Otherwise, the requirements, test methods or test conditions of this common safety publication do not apply.

2 Normative references

The contents of the following documents constitute the essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document. GB/T 2423.4-2008 Environmental testing for electric and electronic products Part 2.Test methods Test Db. Cyclic damp heat (12h 12h cycle) (IEC 60068-2-30.2005, IDT) ISO /IEC Guide 51 Safety aspects - Guidelines for incorporating safety aspects into standards Note. GB/T 20002.4-2015 Drafting of specific contents in standards Part 4.Contents related to safety in standards (ISO /IEC Guide 51. 2014,MOD). Note. GB/T 16927.1-2011 High voltage test technology Part 1.General definitions and test requirements (IEC 60060-1.2010, MOD). Measuring systems Note. GB/T 16927.2-2013 High voltage test technology Part 2.Measurement system (IEC 60060-2.2010, MOD). Note. GB/T 16895 (all parts) Low voltage electrical installations [IEC 60364 (all parts)]. IEC 60364-4-41 Low-voltage electrical installations Part 4-41.Safety protection against electric shock (Low-voltage electrical in-

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 6829-2024_English be delivered?

Answer: Upon your order, we will start to translate GB/T 6829-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 6829-2024_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 6829-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 6829-2024?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 6829-2024 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.