HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (12 Oct 2025)

GB/T 14316-2008 English PDF

US$579.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 14316-2008: PVC insulated ribbon cable with a pitch of 1, 27 mm suitable for insulation displacement termination
Status: Valid

GB/T 14316: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 14316-2008English579 Add to Cart 5 days [Need to translate] PVC insulated ribbon cable with a pitch of 1, 27 mm suitable for insulation displacement termination Valid GB/T 14316-2008
GB 14316-1993English639 Add to Cart 5 days [Need to translate] PVC insulated ribbon cable with a pitch of 1. 27mm suitable for insulation displacement termination Obsolete GB 14316-1993

PDF similar to GB/T 14316-2008


Standard similar to GB/T 14316-2008

GB/T 12706.3   GB/T 12706.1   GB/T 12706.4   GB/T 29631   GB/T 11017.1   GB/T 14315   

Basic data

Standard ID GB/T 14316-2008 (GB/T14316-2008)
Description (Translated English) PVC insulated ribbon cable with a pitch of 1, 27 mm suitable for insulation displacement termination
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K13
Classification of International Standard 29.060.20
Word Count Estimation 25,273
Date of Issue 2008-06-30
Date of Implementation 2009-04-01
Older Standard (superseded by this standard) GB 14316-1993
Adopted Standard IEC 60918-1987, MOD
Regulation (derived from) Announcement of Newly Approved National Standards No. 11 of 2008 (No. 124 overall)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard applies to a pitch of 1. 27mm, cable cores up to 64 cores PVC insulation displacement termination ribbon cable. The cable is long-term working temperature of -10��C ~ 90��C. Consultation with the manufacturer by the customer, the cable can be used in a specific period of time at a higher temperature, but the maximum temperature does not exceed 105��C.

GB/T 14316-2008: PVC insulated ribbon cable with a pitch of 1, 27 mm suitable for insulation displacement termination


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
PVC insulated ribbon cable with a pitch of 1, 27 mm suitable for insulation displacement termination ICS 29.060.20 K13 National Standards of People's Republic of China Replacing GB 14316-1993 1.27 m1 m1 pitch insulation displacement termination PVC insulated ribbon cable (IEC 60918. 1987, MOD) Posted 2008-06-30 2009-04-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Objective 1 3 1 Summary Cable structure 4 1 Mechanical properties 4 5 6 thermal stability requirements 4 7 5 electrical performance requirements 8 5 Inspection Rules Appendix A (informative) color-coded insulated core 6 Appendix B (normative) Test method for folding 7 B. 1 Sample Preparation 7 B. 2 Test procedure 7 B. 3 test results 7 Annex C (normative) tear trough tear tests 8 C. 1 Sample Preparation 8 C. 2 Test procedure 8 C. 3 8 test results Annex D (normative) Test method for flexibility 9 D. 1 Sample Preparation 9 D. 2 Test procedure 9 D. 3 9 test results Appendix E (normative) Thermal Shock Test Method 10 E. 1 Sample Preparation 10 E. Step 2 Test 10 E. 3 10 test results Annex F (normative) Test insulation TGA 11 F. 1 Sample Preparation 11 F. Step 2 Test 11 F. 3 11 test results Annex G (normative) Dimensional Stability Test Method 12 G. 1 Sample Preparation 12 G. Step 2 Test 12 G. 3 12 test results Annex H (normative) Insulation Resistance Test Method 13 H. 1 Sample Preparation 13 H. Step 2 Test 13 H. 3 13 test results Appendix J (normative) soaking pressure test 14 J. 1 Sample Preparation 14 J. Step 2 Test 14 J. 3 14 test results Annex K (normative) tear trough dimensional inspection 15 K. 1 Sample Preparation 15 K. Step 2 Test 15 K. 3 15 test results Annex L (normative) Inspection Rules 16 L. 16 1 Inspection Rules Annex M (informative) This standard reg number and IEC 60918. 1987 reg control number 17 Annex N (informative) Control of old and new versions of the standard clauses 19

Foreword

GB/T 14316-2008 "pitch 1.27mm insulation displacement termination PVC insulated ribbon cable" Edit international standards IEC 60918. 1987 "spaced 1.27mm insulation displacement termination PVC insulated ribbon cable," No. amendments IEC 60918.1992-06 "pitch 1.27mm insulation displacement termination PVC insulated ribbon cable" content is also included in the text, and in They involved the provisions margin identified by the vertical wire. This standard is based on IEC 60918. 1987 redrafted. The standard lists the reg number and IEC 60918 in the Appendix M. 1987 Reg number control list. Taking into account China's national conditions, in using IEC 60918. 1987, the standard of this made some changes, the relevant technical differences have been incorporated into the text, And they are involved in the provision of margin identified by a single vertical line. This standard and IEC 60918. 1987 differences are as follows. --- In order to unify the structure size inspection and test method to increase the "tear trough of dimensions" (this standard 4.3.3) and the "tear trough size detection Check "test method (This standard appendix K); --- Use as a guide, add "inspection rules" (The standard Chapter 8 and Appendix L). For ease of use, the IEC 60918. 1987, this section made the following editorial changes. --- Remove the IEC 60918. 1987 Introduction and Foreword; --- Chapter 2 applicable to the use of standard quotations removed IEC 60918. 1987 quotations. This standard replaces GB 14316-1993 "pitch 1.27mm insulation displacement termination PVC insulated ribbon cable." versus GB 14316-1993 compared to the main changes are as follows (see Appendix N). --- Adds summary (see Excerpts Chapter 3); --- Removed some content (1993 Edition Chapter 3, Chapter 4, 5.1.1, 9, and Appendix K), for example, delete the product code, Product labeling and other content; --- Rating no longer divided heat insulating materials (1993 version 5.1.2 and 5.3.2; edition 5.2); --- No longer divided into different product specifications Inspection Rules (1993 edition 5.3.9; edition 5.4); --- Increasing the pilot project "Insulation hardness test" (see this edition 5.5); --- The table is amended as Appendix (1993 edition Table 4; edition Appendix A); --- Modify the tear trough tear test technical requirements (the 1993 edition of Appendix C; edition 5.4 and Annex C); --- Increasing the thermal shock test of time requirements (Excerpts Appendix E); --- Increased normative appendix "Insulation weightlessness test" (see Appendix F); --- Increased normative appendix "insulation resistance test method" (see Appendix H); --- Increased normative appendix "immersion pressure test method" (see Appendix J); --- Merged content "test" and "inspection rules" (the 1993 version of Chapter 6 and Chapter 8; edition of Appendix L); --- Increase the informative appendix "old and new versions of the standard clauses control" (see Appendix N). The Standard Appendix A, Appendix M and Appendix N is an informative annex; Appendix B, Appendix C, Appendix D, Appendix E, Appendix F, Appendix G, Appendix H, Appendix J, Appendix K and Appendix L is a normative appendix. The standard proposed by China Electrical Equipment Industrial Association. This standard by the National Standardization Technical Committee wire and cable SAC/TC213. This standard was drafted. Shanghai Electric Cable Research Institute. The main drafters of this standard. Yang Yang, Xin Jimin. This standard replaces the previous editions of the standard. --- GB 14316-1993. 1.27 m1 m1 pitch insulation displacement termination PVC insulated ribbon cable

1 Scope

This standard applies to the spacing of 1.27mm, the cable core number is not more than 64 core insulation displacement termination PVC ribbon cable. The cable long-term working temperature of -10 ℃ ~ 90 ℃. By the customer in consultation with the manufacturer, the cable can be used on a particular time At higher temperatures, but the maximum temperature does not exceed 105 ℃. 1.1 Normative References The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 2951.12-2008 and optical cables - Common test methods for insulating and sheathing materials Part 12. General test method Thermal aging methods (IEC 60811-1-2.2000, IDT) GB/T 2951.32-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 32. Polyvinyl chloride mixture Methods specific weight loss test - Thermal stability test (IEC 60811-3-2.2003, IDT) GB/T 11327.1-1999 PVC insulated low-frequency telecommunication cables and wires - Part 1. General test and measurement Volume method (neqIEC 60189-1. 1986) GB/T 18213-2000 frequency cables and wires and coated free copper conductor resistance Calculation Guide (idt IEC 60344. 1980) GB/T 18380.12-2008 burning test and optical fiber cables under fire conditions - Part 12. single insulated wire or cable 1kW pre-mixed combustion test vertical flame test methods (IEC 60332-1-2.2004, IDT) ISO 868.2003 Plastics and rubber --- hard indentation hardness with a durometer (Shore hardness) IEC 60028. 1925 international standard copper resistance IEC 60304. 1982 frequency cables and wires with insulation standard colors Objective 2 This standard aims to regulate this soft, flat, unshielded PVC insulated cables (including solid conductors and stranded conductors) Technical requirements and size specifications. This displacement termination ribbon cable rated voltage of 300V and below of household appliances, electronic equipment within Unit to use. In order to facilitate transport, the cable needs to be wound on a cable tray can even withstand temperatures of -55 ℃. However, before use, the cable should At least 15 ℃ environment stable for some time.

3 Summary

The manufacturer has the responsibility to establish a quality assurance system, through quality control procedures to ensure that products meet the requirements of this standard. But that does not mean For each of the conductors and cables must be complete experimental verification. When customers have a designated product but acceptable testing requirements or When asked his quality program, the supply and demand sides should reach a consensus through coordination.

4 cable structure

4.1 Conductor 4.1.1 conductor by the annealing copper wire, copper wire material should be uniform, defect-free. Conductor resistance should be consistent with IEC 60028. 1925 requirements.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 14316-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 14316-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 14316-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 14316-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 14316-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 14316-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.