Basic data

Standard ID CNCA C18-04-2014 (CNCA-C18-04-2014)
Description (Translated English) China Compulsory Certification Implementation Rules - Fire equipment products
Sector / Industry China Compulsory Certification (CCC) Implementation Rules
Classification of Chinese Standard CNC
Classification of International Standard CNCA 2014 Notice No. 15
Word Count Estimation 15,123
Date of Issue 5/30/2014
Date of Implementation 9/1/2014
Regulation (derived from) CNCA 2014 Notice No. 15
Issuing agency(ies) China National Accreditation Administration for Certification and Accreditation
Summary This standard specifies the China Compulsory Certification (CCC) implementation rules for Fire equipment products. This standard defines the Fire equipment products's certification unit; certification entrusting; document requirements; sample requirements

CNCA C18-04-2014: China Compulsory Certification Implementation Rules - Fire equipment products

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
CNCA -C18-04-2014 Number. CNCA -C18-04.2014 Mandatory product certification and implementation rules Fire Equipment Products Issued on. 2014-05-30 2014-09-01 implementation China Certification and Accreditation Administration Commission issued

table of Contents

0 Introduction 1 1. Scope ..1 2 Standards for Certification ..1 3 Authentication Mode 1 4 certification application unit 2 5 .2 for Certification 5.1 proposed commission of the certification and acceptance of .2 5.2 application information .2 5.3 implementation arrangements .3 6 .3 Certification 6.1 Type tests .. 3 6.2 Quality assurance and product consistency check (initial factory inspection) 4 6.3 Evaluation and Certification decisions 5 6.4 Time frame for certification 5 7-up inspection 5 After 7.1 certified sampling areas of use or to check .5 Follow-up examination after ..6 7.2 certified 7.3 certified production site inspection or sampling areas 6 7.4 up inspection frequency and time 7 7.5 certified after supervision records ..7 7.6 up inspection after evaluation of the results 7 8 Certificate .7 8.1 certificate is valid ..7 8.2 Certificate Content 8 Change 8.3 Certification/expansion ..8 8.4 certificate cancellation, suspension and revocation of 8 Use certificates 8 8.5 9 certification mark .8 9.1 of marks ..8 9.2 Requirements ..9 10 ..9 charges 11 certification responsibilities .9 12 Certification Rules .9 Fire accessory equipment products compulsory certification application unit and Standards for Certification ..11 0 Introduction These rules follow the laws and regulations on fire protection products market access basic requirements, based on fire-fighting equipment Security risks and risks certified product formulation, provides fire equipment products mandatory product recognition Certified basic principles and requirements. The rules and CNCA issued a "compulsory product certification and implementation rules, the company points Class management, authentication mode selection and determination "," compulsory product certification and implementation rules, the company seized Resources and measure results using other authentication "," compulsory product certification rules through factory inspection With the requirements "and supporting the use of general implementing rules. The certification body should be based on common rules and the implementation of this rule requires the preparation of certification implementation details, and with Sets common rules and implement common rules of this embodiment. Manufacturers should ensure that certified products can continue to meet the applicable standards and certification begging.

1 Scope

This rule applies to fire equipment products, including the following product categories. positive pressure firefighting air call Haustorium, firefighters personal protective equipment, fire motorcycles, rescue products, product escape from Rescue respirator.

2 Standards for Certification

Standards for Certification Annex "fire equipment products compulsory certification and certification according to cell division standard". These criteria should in principle be running the latest version of the national standardization administrative department issued when Need to use other versions of the standard, then the relevant standard shall apply the requirements of the state commission issued Announcement execution.

3 authentication mode

Basic authentication mode to implement mandatory certification of fire equipment products are. Type test corporate quality assurance and product consistency check after use certified areas Sampling and testing or inspection The certification body shall "compulsory product certification and implementation rules production enterprise management, identify Card mode selection and determination "requirements, the production enterprises category management, category management and combined Resulting in increased follow-up examination after granting the certificate, as appropriate, on the basis of the basic authentication mode after the production is now certified Field extraction and other related elements of sample testing or inspection to determine the client can authenticate the applicable certification mode.

4 certification application unit

In principle, the same producer (manufacturer), the same company (factory), the same category, The same structure, the same form, the same material as a certified unit. Certification means the principal basis for dividing principles for certification commission. Certification Unit Division Annex "fire equipment products compulsory certification and certification according to cell division standard".

5 certified delegate

5.1 certification commission proposed and accepted Certification principal needs in an appropriate manner to the certification commission for accreditation bodies, certification bodies respond Certification can be processed and certified in accordance with the Regulations of the time limits for accepting or not subject to feedback Management information. Not in accordance with national laws and regulations and relevant industrial policies, the certification body shall not accept the relevant Certification commission. Fire Motorcycle certified client to determine the company and its production process should meet the strong motorbike Relevant provisions of the compulsory product certification management. 5.2 Application Information The certification body should be based on laws, regulations, standards and certification and implementation of the necessary implementing regulations certification Clear application data list (or certification application shall include at least contract, certified principal/producer / Company registration certificate, etc.). Authentication Client shall provide the necessary funding in accordance with the Regulations of the certification requirements of the application lists Material. The certification body is responsible for audit, management, preservation, confidential information, and data audit results Inform the client authentication. 5.3 Implementation Arrangements The certification body and certification should be the principal sides agreed to implement all aspects of the relevant certification and responsibility Arrangement, and according to their actual production and management of classification, according to the rules and implementation of certification rules Requirements, determine the authentication implementation of specific programs and inform the authentication principal.

6 Certification

6.1 Type tests Designated laboratories shall sign a contract type testing and certification clients, including type testing of all Sample requirements and the number of testing standards projects. 6.1.1 Type test sample request The certification body should be based on the production of enterprise management, the implementation of certification rules expressly unit Or a combination of sample units/send samples of the specific requirements of the type test sample can be taken on-site sampling/sample letters party Formula obtained can also be certified in accordance with the above requirements the client to send samples. Authentication Client shall ensure the consistency of the sample and the actual production of products it provides. CB Structure and/or laboratory response authentication provided by the client to review the authenticity of the sample laboratory samples Authenticity of doubt, it should explain the situation to the certification body, and make the appropriate treatment. 6.1.2 Type test project Fire equipment type test shall be the basis for project certification standards. Implementation 6.1.3 type testing Type test should be completed by the national commission designated laboratories laboratory samples for type Test, and make a complete record of the whole process of detection and archive retained to ensure that the testing process and results Records traceable. 6.1.4 Type test report The certification body should specify a uniform type test report format. After the type test, the laboratory shall inform the certification body type test certification issued by the principal Inspection report. The test report shall contain all product-related information in the application and certification unit will be described. Certification principal shall ensure that in the follow-up inspection to be able to provide complete certification bodies and law enforcement agencies have Efficiency type test report. 6.2 Quality assurance and product consistency check (initial factory inspection) After the type test certificate for construction enterprise quality assurance and product consistency check. 6.2.1 Basic Principles The certification body should be clearly Manufacturer/producer corporate quality assurance certification capability and capacity in implementing regulations Product consistency control of basic requirements. Certification and principal producers/manufacturers should be certified in accordance with the relevant provisions of the Regulations, the establishment Maintaining effective corporate quality assurance and product consistency control system and maintain fire equipment Production conditions of products, ensure product quality, marks, logos continued compliance with relevant laws and regulations and standards Registration requirements to ensure that certified products continue to meet certification requirements. Producer/manufacturer shall establish the production, the flow of sales registration system, accurately record yield Product name, batch, size, quantity, destination marketing and so on. The certification body shall producer/manufacturer of quality assurance and product consistency control of feed Line compliance check. Approvals for producers/manufacturers, certification bodies can corporate quality assurance capabilities and The timing and content of the product consistency check to make proper adjustments, and clear in certification implementation details. 6.2.2 Quality assurance inspection capacity requirements Mandatory product certification inspector certification body should appoint a national registered qualifications composed inspection Investigation group, according to "fire products factory inspection General requirements" (GA 1035) and Certification Regulations The relevant requirements of the producer/manufacturer for quality assurance ability. Check shall cover all the authentication unit involved in the company, if necessary, the certification body to be born Place outside production companies to implement extended inspections. 6.2.3 product consistency inspection requirements Certification bodies by the producer/manufacturer, certificated products randomly selected for Certification Products in accordance with "Fire product consistency inspection requirements" (GA 1061) and the Regulations relating to certified Requirements for product consistency check. 6.3 Evaluation and Certification decisions The certification body type test, corporate quality assurance and product consistency check and conclusions Relevant data/information and a comprehensive evaluation, certification decision. To meet the certification requirements, recognition award Cert; the existence of unqualified conclusion, the certification body shall not be approved for Certification, certification terminated. 6.4 Time frame for certification The certification body shall limit certification to make clear that all sectors, and to ensure that related work on time Limit required to complete Authentication Client shall actively cooperate in certification activities. Under normal circumstances, since the subject Management certification from the commission to the authentication certificate issued by the client within 90 days. Standards for Certification of detections Head and the time required to have special requirements, the certification body should be clearly detected in the product certification implementing regulations time limit. 7-up inspection Certified after supervision refers to the certification body to the certified products and their producers/manufacturers to implement monitoring Governor Fire equipment products to take follow-up inspection after inspection using the sampling and testing in the field or check the square Type implementation. The certification body may also be combined with the production of certified enterprise management and the actual situation, increase up inspection Follow-up examination, after inspection production site sample or to check the way up inspection after the implementation, Specific requirements should be clear in certification implementation details. 7.1 Follow-up inspection or sampling areas of use 7.1.1 Principles Follow-up sampling and testing or inspection should cover a certain percentage of certified products in the field. After taking the field to use certified sampling or to check up inspection after the implementation of the certification commission People, producers, manufacturers and should be confirmed with samples taken from the field of use. 7.1.2 Content Follow-up sampling is used to detect areas. certification in accordance with standards and certification in accordance with requirements of the Regulations, After sampling fields of use, by a designated testing laboratory implementation. Follow-up sampling areas of use. According to "fire products on-site inspection to determine the rules" (GA 588), "fire inspection requirements for product consistency" (GA 1061) and certification requirements of the Regulations, By the certification body in the field of use of fire equipment products implement checks. The certification body should be used in the authentication implementation rules in the field sampling and testing or examination specifically certified Content, approach and requires special circumstances. Follow-up examination after 7.2 certified 7.2.1 Principles The certification body should be based on the production and enterprise management, the certified products and their producers/students Production enterprises to implement effective follow-up inspection to verify producer/manufacturer's quality assurance ability to continue Meet the certification requirements to ensure that certified products meet standard requirements and keep up with the type of test sample consistency. Follow-up examination after granting the certificate shall, at the producer/manufacturer of normal production, preferred without prior Inform the conduct of inspection side. For non-continuous production of the product, the client should Certification Certification Production-related agencies to submit plans to facilitate follow-up examination after granting the certificate effectively. Take follow-up examination after the implementation of the certified way certified after supervision, certification clients, producers, Production enterprises should cooperate. 7.2.2 Content The certification body shall "compulsory product certification and implementation rules factory quality assurance ability to Seek "," fire products factory inspection General requirements "(GA 1035)," Fire product consistency check Charles Requirements "(GA 1061), the contents of the authentication implementation rules expressly certified after the track inspection, Approach requirements and special circumstances. 7.3 certified production site in the field or after sampling inspection 7.3.1 Principles Follow-up sample detection or production site inspection should cover the certified products unit. After taking the certified production site inspection or sample detection mode after the implementation of certified oversight Authentication client, producers, production companies should cooperate. 7.3.2 Content After the certified production site sample testing. in accordance with the requirements of the standard for certification, is now in production Backcourt sample detected by designated laboratories implemented as the company with the "Compulsory Certification and implementation rules, the company testing resources and use requirements "Other certification and certification according to the results of According to requirements of the standard test conditions, the certification body can use company resources to implement detection detection (or Witnessed detection), and recognize the correlation results; such as production companies do not have the above test conditions, the sample should be Goods sent to the designated laboratory testing. The certification body should use authentication implementation rules expressly subject company Measured resources to implement the detection of specific requirements and procedures. Follow-up sample production site inspection. according to "fire inspection requirements for product consistency" (GA 1061) and the requirements of the certification implementation rules by the certification body at the production site of the fire equipment products real Shi checks. After the certification body should be clearly certified in certification implementation rules in the production site or sample detection Check the contents, requirements and approaches in special circumstances. 7.4 up inspection frequency and time The certification body should be based on the production of enterprise management, enterprise communications products produced by students Factory production batch and conduct sample testing or inspection of the different categories, the company does not take Supervision of certified after the same frequency to determine a reasonable time supervision, specific principles should be certified implementing regulations To be clear. 7.5 up inspection records The certification body shall record the whole process of follow-up inspection and archive retained to ensure certification Process and results traceable. After 7.6 certified evaluation of inspection results The certification body sample detection/inspection results and relevant data/information comprehensive evaluation. Comment By price, we can continue to maintain certification, the use of certification marks; evaluation is not adopted, the certification Configuration should be made cancellation/suspend/revoke certification process in accordance with the respective circumstances, and to the public.

8 Certification

8.1 certificate is valid Covered by this rule certificate is valid for 5 years within the validity period, the certificate has After the validity of the certification body depend certified inspection. Certificate expiry, the need to continue to use, should be the principal certification certification Before the expiry of accreditation commission 90 days after the last certificate is valid up inspection knot If qualified, the certification body shall issue a new certificate directly after receiving the certification commission. 8.2 Certificate Content Certificate content should follow the "compulsory product certification regulations," Article XXI requirements. Change 8.3 Certification/expansion Follow-up, when other matters involving certification, product features or the certification body occurs When changes need to be extended or authentication client has obtained certification covering product range, After the principal certification certification bodies should change/extension commission, change/extend the approval of certification bodies Before implementation. The certification body should be under the premise of risk control, certification implementing rules explicitly change/extension to Seek, and change/extend the content document review, inspection and/or inspection (where applicable), the evaluation through After only approve the change/extension. 8.4 certificate cancellation, suspension and revocation Cancellation of certificates, suspension and revocation, based on "compulsory product certification regulations," and "Compulsory Certification cancellation, suspension, revocation implementing rules" and the relevant provisions of the certification body Scheduled execution. The certification body shall determine does not meet the certification requirements and the scope of product categories, and to take appropriate It is announced by way of cancellation, suspension and revocation of certificates. 8.5 Use of certificates Use of the certificates shall comply with the "Regulations for Compulsory Product Certification" requirements.

9 certification mark

Certification mark of the management, use should follow the "Compulsory Certification Mark" to begging. 9.1 Shape Flag Certified fire equipment fire product should be used Class (F) certification mark, style is as follows. 9.2 Requirements Certification marks shall be applied on the apparent position of the product, the certification body should be certified implementing regulations Clear and specific requirements. 10 charges Certification fees by the certification bodies and laboratories on the national compulsory product certification fees in accordance with Provisions of the standard fee. The certification body shall be in accordance with national mandatory product certification fees on the initial factory inspection, Follow-up inspection fee prescribed man-days to review the standard, reasonably determine the specific charges man-days. 11 certification responsibilities The certification body shall be responsible for the certification results. The laboratory shall be responsible for test results and inspection reports. The certification body and respond appointed factory inspectors responsible for factory inspection. Certification principal responsible for the authenticity of their information and samples submitted legitimacy. 12 Certification Rules The certification body should be based on the principles and implementation of the r...