US$769.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. YY/T 0084.1-2009: Strength calculation and relevant regulations of primary pressure components of cylindrical pressure steam sterilizer YY/T 0084.1: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| YY/T 0084.1-2009 | English | 769 |
Add to Cart
|
4 days [Need to translate]
|
Strength calculation and relevant regulations of primary pressure components of cylindrical pressure steam sterilizer
| |
YY/T 0084.1-2009
|
| YY/T 0084.1-1992 | English | 919 |
Add to Cart
|
6 days [Need to translate]
|
Major pressure component of round pressure and steam sterilizer Calculation of intension and related stipulations
| Obsolete |
YY/T 0084.1-1992
|
PDF similar to YY/T 0084.1-2009
Standard similar to YY/T 0084.1-2009 YY/T 0802.1 YY/T 1268 YY 0451 YY/T 0802.2
Basic data | Standard ID | YY/T 0084.1-2009 (YY/T0084.1-2009) | | Description (Translated English) | Strength calculation and relevant regulations of primary pressure components of cylindrical pressure steam sterilizer | | Sector / Industry | Medical Device & Pharmaceutical Industry Standard (Recommended) | | Classification of Chinese Standard | C47 | | Classification of International Standard | 11.080.99 | | Word Count Estimation | 22,261 | | Date of Issue | 2009-06-16 | | Date of Implementation | 2010-12-01 | | Older Standard (superseded by this standard) | YY/T 0084.1-1992 | | Quoted Standard | GB 150-1998; GB 4793.4-2001; JB/T 4755-2006; JB/B 4734-2002; YY 0154; YY/T 0159; Pressure Vessel Safety Technology Supervision 1999 | | Regulation (derived from) | Industry standard filing Notice 2009 No. 9 | | Issuing agency(ies) | State Food and Drug Administration | | Summary | This standard specifies the single, double round pressure steam sterilizer main pressure components strength calculation and the relevant provisions of this section have not been provided for by the relevant standards. This standard applies to the design pressure of not more than 0. 4MPa circular pressure steam sterilizer. Also suitable for carrying a circular negative pressure steam sterilizer. |
YY/T 0084.1-2009: Strength calculation and relevant regulations of primary pressure components of cylindrical pressure steam sterilizer ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Strength calculation and relevant regulations of primary pressure components of cylindrical pressure steam sterilizer
ICS 11.080.99
C47
People's Republic of China pharmaceutical industry standards
Replacing YY/T 0084.1-1992
Round Pressure Steam Sterilizer
The main pressure parts strength calculation and the relevant provisions
Posted 2009-06-16
2010-12-01 implementation
State Food and Drug Administration issued
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 Materials 4
5 sterilizer cylinder strength calculation 5
6 head 7
7 cover 10
8 with the coupling flange 12
Safety accessories 9 sterilizers and related provisions 17
Foreword
YY/T 0084 is divided into two parts.
--- Round Pressure Steam Sterilizer main pressure parts strength calculation and the relevant regulations;
--- Rectangular Pressure Steam Sterilizer main pressure parts strength calculation and the relevant regulations.
This section YY/T Section 10084 of.
This section instead of YY/T 0084.1-1992 "Round Pressure Steam Sterilizer main pressure parts strength calculation and the relevant provisions."
Section compared with YY/T 0084.1-1992 The main changes are as follows.
--- All the symbols in this section, the terms, definitions, formulas, selection of materials according to the provisions of GB 150-1998, in addition to special
Special type flange strength calculations.
--- Main pressure computing element.
1) The main pressure components. cylinder, stiffening ring, head, cover, flange calculations using the appropriate strength GB 150-1998
Calculation formula to calculate the sterilizer remains common structure;
A unified formula by calculating the thickness δ, without design thickness δ '.
2) on the cylinder head, computing cover, in particular, the strength of the external pressure calculation chart uses specified in GB 150-1998
Determining deleting the original standard, "Ram formula" and so on;
3) to retain the original standard loose flange, integral flange and any type flange type. And the figures are calculated using formulas symbol
GB 150-1998 standard (except for special types of flange);
4) retention patterns and formulas YY/T 0084.1-1992 commonly used in sterilization of the flange to retain the calculation of the coupling member
formula;
5) safety accessories sterilizer and its relevant regulations, legal standards promulgated by various safety accessories new execution; according to GB 4793.4-
2001 and "Pressure Vessel Safety Technology Supervision" provides the development of security requirements.
6) Delete YY/T 0084.1-1992 "5 and the welding seam coefficient", "6 qualifications and responsibilities." Relevant regulations and strength calculation
Set, is described in Chapter 9.
This part is proposed by the State Food and Drug Administration.
This part of the National Standardization Technical Committee centralized disinfection technology and equipment.
This section is drafted. Shanghai Hua nuclear Line Medical Instrument Co., Ltd., Guangzhou, the State Food and Drug Administration Medical Devices Quality supervision
Governor Inspection Center of Shandong Xinhua Medical Instrument Co., Ltd.
The main drafters of this section. Zhong Bo cattle, Zhenghong Qin, Xu Honglei, Wang Daojun.
This part of the standard replaces the previous editions are.
--- WS2/Z-19-1975, YY/T 0084.1-1992.
Round Pressure Steam Sterilizer
The main pressure parts strength calculation and the relevant provisions
1 Scope
YY/T 0084 provisions of this part of the single, double round pressure steam sterilizer (hereinafter referred to as sterilization) main pressure parts strength
Calculation and the relevant provisions of this Part were not specified by the corresponding standards.
This section applies to the design pressure is less than 0.4MPa circular pressure steam sterilizer.
This section also applies to circular bearing negative pressure steam sterilizer.
2 Normative references
The following documents contain provisions which, through reference YY/T 0084 to the present, constitute provisions of this section. For dated reference documents
Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section
Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this
section.
GB 150-1998 Steel Pressure Vessels
GB 4793.4-2001 measurement, control and laboratory use electrical safety laboratory equipment used in the processing of medical materials autoclave
Particular requirements (IEC 61010-2-041.1995, IDT)
JB/T 4755-2006 Copper Pressure Vessels
JB/B4734-2002 welding aluminum container
YY 0154 pressure steam sterilization equipment with a spring-loaded safety valve
YY/T 0159 Pressure Steam sterilization equipment with trap
Pressure Vessel Safety Technology Supervision 1999
3 Terms and Definitions
The following terms and definitions apply YY/T 0084 of this section.
3.1
Design pressure means the maximum pressure setting sterilizer top of the container, together with the corresponding design temperature as the design load condition, its value is not
Lower than the operating pressure.
3.2
Calculation means at a pressure corresponding to the design temperature, the pressure used to determine the thickness of the component, including the static pressure liquid column. When the element is exposed
When the liquid column static pressure is less than 5% of the design pressure is negligible.
3.3
Design temperature sterilizer means under normal working conditions, the temperature of the metal elements is set (in the average temperature of the metal section member).
Design temperature and design pressure together as the design load conditions.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY/T 0084.1-2009_English be delivered?Answer: Upon your order, we will start to translate YY/T 0084.1-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YY/T 0084.1-2009_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 0084.1-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version YY/T 0084.1-2009?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY/T 0084.1-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|