YS/T 901-2024EnglishRFQ ASK 3 days [Need to translate] (Chemical analysis method for high purity tungsten - Determination of trace element content - Glow discharge mass spectrometry) Valid YS/T 901-2024
YS/T 901-2013English239 Add to Cart 3 days [Need to translate] Methods for chemical analysis of high purity tungsten. Determination of trace impurity element content. Glow discharge mass spectrometry Obsolete YS/T 901-2013

Basic data

Standard ID YS/T 901-2024 (YS/T901-2024)
Description (Translated English) (Chemical analysis method for high purity tungsten - Determination of trace element content - Glow discharge mass spectrometry)
Sector / Industry Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard H14
Classification of International Standard 77.120.99
Date of Issue 2024-10-24
Date of Implementation 2025-05-01
Older Standard (superseded by this standard) YS/T 901-2013
Issuing agency(ies) Ministry of Industry and Information Technology
Summary This standard specifies the determination method of trace element content in high-purity tungsten by glow discharge mass spectrometry. This standard is applicable to the determination of trace element content in high-purity tungsten.

YS/T 901-2013: Methods for chemical analysis of high purity tungsten. Determination of trace impurity element content. Glow discharge mass spectrometry


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of high purity tungsten. Determination of trace impurity element content. Glow discharge mass spectrometry ICS 77.120.99 H63 People's Republic of China Nonferrous Metals Industry Standard Methods for chemical analysis of high purity tungsten Determination of trace elements Glow Discharge Mass Spectrometry Issued on. 2013-10-17 2014-03-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard by the national non-ferrous metals Standardization Technical Committee (SAC/TC243) centralized. This standard was drafted. Beijing Nonferrous Metal Research Institute, Jinchuan New Material Technology Co., Ltd., Dongfang Electric Group Emei semiconductor Material Co., Ltd. The main drafters of this standard. Li Po City, Liu Ying, Sun Zeming, Tong Jian, Li Jidong, Zang Muwen, Li Na, Chengzi Hui, Zhangjiang Feng, Qiu Ping, Qinfang Lin, Wenying, Wang Panfeng. Methods for chemical analysis of high purity tungsten Determination of trace elements Glow Discharge Mass Spectrometry

1 Scope

This standard specifies the method for the determination of trace elements in high purity tungsten content, the determination of elements in Table 1. This standard applies to the determination of trace elements in high purity tungsten content. Determination of the elements in the range of 1μg/kg ~ 5000μg/kg.

2 principle of the method

Sample as the cathode glow discharge, and the surface thereof is sputtered atoms from the sample into the plasma in the glow discharge, is ionized and then Import mass spectrometer for measurement. In each element isotope mass number punishable by default scan points and the integration time of the corresponding peak integration, the Area of peak intensity is obtained. In the absence of a standard sample, according to the instrument computer software "typical relative sensitivity factor" calculated automatically The mass fraction of the elements; when the standard sample is required by the sample in the same assay conditions, the ion source structure and the test conditions Under the standard sample was determined by independent relative sensitivity factor, the application of the relative sensitivity factor to calculate the mass fraction of the elements. Element content measured in mass fraction w (X) dollars, to μg/kg expressed by the formula (1). w (X) = RSF (X/W) · IX · AW IW · AX · W (W) (1) Where. w (X) --- analyte concentration, in micrograms per kilogram (μg/kg); RSF (X/W) --- W is the correction coefficient of the element X was measured under specified conditions of glow discharge; Isotope peak intensity IX --- tested element X, cps; Isotope peak intensity IW --- W elements, cps; AX --- analyte X isotopic abundance; AW --- W isotope abundances of elements; Definition mass fraction w (W) --- W is 1.00 × 109μg/kg.

3 Reagents and materials

Unless otherwise indicated, the reagents used in the analysis are excellent pure; water used as a water. 3.1 ethanol. 3.2 Argon (φ≥99.999%). 3.3 Hydrofluoric acid (19). 3.4 W standard sample, measured elements mass fraction of 50μg/kg ~ 500μg/kg. 3.5 tungsten blank samples, measured element quality requirements over the sample under test scores below 10 times.

4 Instrument

4.1 high resolution glow discharge mass spectrometer, under the resolution mode resolution of up to 3000 to 4000, high-resolution mode resolution Rate of up to 9,000 to 10,000.