|
US$229.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 694.3-2017: (Deformed aluminum and aluminum alloy energy consumption per unit of product limit - Part 3: Foil) Status: Valid YS/T 694.3: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| YS/T 694.3-2017 | English | 229 |
Add to Cart
|
3 days [Need to translate]
|
(Deformed aluminum and aluminum alloy energy consumption per unit of product limit - Part 3: Foil)
| Valid |
YS/T 694.3-2017
|
| YS/T 694.3-2009 | English | 239 |
Add to Cart
|
3 days [Need to translate]
|
The norm of energy consumption per unit product of wrought aluminium and aluminium alloy. Part 3: Foils
| Obsolete |
YS/T 694.3-2009
|
PDF similar to YS/T 694.3-2017
Basic data | Standard ID | YS/T 694.3-2017 (YS/T694.3-2017) | | Description (Translated English) | (Deformed aluminum and aluminum alloy energy consumption per unit of product limit - Part 3: Foil) | | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | | Classification of Chinese Standard | F01 | | Word Count Estimation | 10,11 | | Date of Issue | 2017-11-07 | | Date of Implementation | 2018-04-01 | | Older Standard (superseded by this standard) | YS/T 694.3-2009 | | Regulation (derived from) | Ministry of Industry and Information Technology Bulletin 2017 No.48 | | Issuing agency(ies) | Ministry of Industry and Information Technology | | Summary | This standard specifies the technical requirements, calculation principles, calculation scope, calculation methods and energy conservation management and measures for energy consumption limits of deformed aluminum and aluminum alloy foil products. |
YS/T 694.3-2009: The norm of energy consumption per unit product of wrought aluminium and aluminium alloy. Part 3: Foils ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
The norm of energy consumption per unit product of wrought aluminium and aluminium alloy.Part 3. Foils
ICS 27.010
F01
People's Republic of China Nonferrous Metals Industry Standard
Wrought aluminum and aluminum alloy energy consumption per unit product
Part 3. foil
Posted 2009-12-04
2010-06-01 implementation
Ministry of Industry and Information Technology of the People's Republic of China released
Foreword
The provisions of this section in Chapter 4 of the existing production quota limits energy companies and new production enterprise energy consumption limits access value is mandatory
And the rest are recommended.
YS 694 "Wrought aluminum and aluminum alloy energy consumption per unit product" is divided into four parts.
--- Part 1. casting ingot;
--- Part 2. plate, strip;
--- Part 3. foil;
--- Part 4. extruded profiles and pipe.
This is Part 3 YS 694 of.
The non-ferrous metal part by the National Standardization Technical Committee and centralized.
This part mainly drafted by. Southwest Aluminum (Group) Co., Ltd., China Nonferrous Metals Industry Standards and Metrology Institute for Quality.
Participated in the drafting of this section. Northeast Light Alloy Co., Ltd., China Aluminum Industry Branch of Northwest Aluminum, Aluminum Foil Co. Xiashun
The company, Chinalco Ruimin Co., Ltd., Yunnan new Alcoa Aluminum Foil Co., North China Aluminum Co., Ltd., Guangdong East Sunshine Aluminum shares have
Limited, Alcoa Aluminum Co., Ltd. Jiangsu often participated in the drafting.
The main drafters of this section. Xia Qiming, Geli Xin, Hu Changyun, Lee Shui-shan, Wang Zhengan, Lv Xinyu, CIVIL Guojun, paragraph remifentanil,
Hou Bo, Bo Changhai.
Wrought aluminum and aluminum alloy energy consumption per unit product
Part 3. foil
1 Scope
This section provides aluminum foil unit product energy consumption (hereinafter referred to as energy) limit requirement calculation principles, calculation range, calculation method
And energy management and measures.
This section applies to aluminum foil production enterprises unit energy consumption calculation and assessment 1), as well as new projects of energy control.
1) yield the corresponding unit product energy consumption limits of enterprise products to corporate reporting period, production of various types of qualified products and the product of the limit test carried out
Nuclear assessment.
2 Normative references
The following documents contain provisions which, through reference YS/T 694 of this text, constitute provisions of this section. Cited documents dated, its
All subsequent amendments (not including errata content) or revisions do not apply to this section, however, encourage each agreement under this section
Are Prescriptions can use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.
3 Terms and Definitions
Terms and definitions YS 694.1-2009 provisions applicable to this section.
4 Requirements
Wrought aluminum and aluminum foil production enterprises existing limit energy consumption limits, the new company values and energy consumption limits access to quota
Binary values should be consistent with the requirements of Table 1. When business is located north of the Yangtze, the table shall be multiplied by the value of energy consumption limits south of the correction coefficient K (Shanhaiguan, take
K = 1.1; Shanhaiguan north, take K = 1.2); when business is located at an altitude of more than 1500m, the table should be multiplied by the value of energy consumption limits into 1.03
Line correction.
Table 1 unit product energy consumption limits
Product Categories
raw material
Unit product energy consumption limits/(kgce/t)
Existing production enterprises
Limit energy consumption limits 1)
New company
Energy consumption limits access value 2)
Energy consumption limits
Advanced value 3)
Integrated energy technology energy technology energy technology integrated energy consumption overall energy consumption
No Zero foil 0.1000 ~ 0.2000 cold-rolled ≤300 ≤335 ≤205 ≤225 ≤175 ≤195
Single zero foil 0.0100 ~ 0.0999 cold-rolled ≤335 ≤370 ≤225 ≤255 ≤190 ≤215
Double zero foil 0.0040 ~ 0.0099 cold-rolled ≤360 ≤410 ≤245 ≤280 ≤205 ≤230
Surface-treated aluminum foil 0.0040 ~ 0.2000 ≤150 ≤170 ≤120 ≤140 ≤100 ≤115
1) aluminum foil production process if there is no annealing step, the energy consumption values in the table minus 97.
2) aluminum foil production process if there is no annealing step, the energy consumption values in the table minus 89.
3) aluminum foil production process if there is no annealing step, the energy consumption values in the table minus 86.
5 energy calculation principles, calculation methods and calculation range
5.1 Energy consumption calculation principles
Energy consumption calculation principles should comply with the provisions of Article 5.1 YS 694.1-2009.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 694.3-2017_English be delivered?Answer: Upon your order, we will start to translate YS/T 694.3-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YS/T 694.3-2017_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 694.3-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version YS/T 694.3-2017?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 694.3-2017 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|