HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (25 Oct 2025)

YS/T 581.16-2008 English PDF

US$209.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YS/T 581.16-2008: Chemical analysis methods and determination of physical performance of industrial aluminium fluoride. Part 16: X-ray fluorescence spectrometric method for the determination of elements content
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YS/T 581.16-2008English209 Add to Cart 3 days [Need to translate] Chemical analysis methods and determination of physical performance of industrial aluminium fluoride. Part 16: X-ray fluorescence spectrometric method for the determination of elements content Valid YS/T 581.16-2008

PDF similar to YS/T 581.16-2008


Standard similar to YS/T 581.16-2008

YS/T 575.23   GB/T 23615.1   YS/T 575.24   YS/T 581.8   YS/T 581.9   YS/T 581.19   

Basic data

Standard ID YS/T 581.16-2008 (YS/T581.16-2008)
Description (Translated English) Chemical analysis methods and determination of physical performance of industrial aluminium fluoride. Part 16: X-ray fluorescence spectrometric method for the determination of elements content
Sector / Industry Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard H30
Classification of International Standard 77.120.10
Word Count Estimation 8,820
Date of Issue 2008-03-12
Date of Implementation 2008-09-01
Regulation (derived from) NDRC Notice No. 25 of 2008
Issuing agency(ies) National Development and Reform Commission
Summary This standard specifies the aluminum fluoride, fluorine, aluminum, sodium, silicon, iron, sulfur, and phosphorus content (in F, Al, Na, SiO2, Fe2O3, SO42-, P2O5: representation) measurement method. This standard applies to aluminum fluoride, fluorine, aluminum, sodium, silicon, iron, sulfur and phosphorus content. Measuring range in Table 1.

YS/T 581.16-2008: Chemical analysis methods and determination of physical performance of industrial aluminium fluoride. Part 16: X-ray fluorescence spectrometric method for the determination of elements content



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Chemical analysis methods and determination of physical performance of industrial aluminium fluoride.Part 16. X-ray fluorescence spectrometric method for the determination of elements content ICS 77.120.10 H30 People's Republic of China Nonferrous Metals Industry Standard Aluminum fluoride Chemical analysis methods and physical properties Measuring methods - Part 16. X-ray fluorescence Spectrometry determination of elements content Posted 2008-03-12 2008-09-01 implementation National Development and Reform Commission issued

Foreword

YS/T 581 "aluminum fluoride chemical analysis methods and determination of physical performance" is divided into 16 parts. --- Part 1. Determination of the content of water in wet weight method; --- Part 2. Determination of burning reductions; --- Part 3. distillation - thorium nitrate volumetric method for the determination of fluorine content; --- Part 4. Determination of aluminum content - EDTA volumetric method; --- Part 5. Determination by flame atomic absorption spectrometry sodium content; --- Part 6. molybdenum blue spectrophotometric determination of silicon dioxide content; --- Part 7. phenanthroline spectrophotometric determination of ferric oxide content; --- Part 8. Determination of sulfate content barium sulphate gravimetric method; --- Part 9. molybdenum blue spectrophotometric determination of phosphorus pentoxide content; Part --- Article 10. X-ray fluorescence spectrometric method for the determination of sulfur content; --- Part 11. sample preparation and storage; --- Part 12. Determination of particle size distribution - sieving method; --- Part 13. Determination of angle of repose; --- Part 14. Determination of bulk density; --- Part 15. Determination of free alumina content; --- Part 16. Determination of Elements in X-ray fluorescence spectroscopy. This is Part 16. Appendix A of this section is an informative annex. The non-ferrous metal part by the National Standardization Technical Committee and centralized. This part of the Aluminum Corporation of China Zhengzhou Research Institute, China Nonferrous Metals Industry Institute of Standards Metrology and Quality is responsible for drafting. This section is more fluoride Chemical Co., Neimengguhuo coal Hongjunlvdian limited liability company, Fujian Nanping Aluminium Co., Ltd. participated Drafted. The main drafters of this section. Zhangai Fen, Zhang North Korea, Mahui Xia, Xi Huan, Xu Jin Xue, Li Zhihui, Shiji Qin. Aluminum fluoride Chemical analysis methods and physical properties Measuring methods - Part 16. X-ray fluorescence Spectrometry determination of elements content

1 Scope

This section provides aluminum fluoride, fluorine, aluminum, sodium, silicon, iron, sulfur, phosphorus content (F, Al, Na, SiO2, Fe2O3, SO2-4, P2O5 represented) Measurement method. This section applies to fluorine, aluminum, sodium, silicon, iron, sulfur, aluminum fluoride determination of phosphorus content. Determination of the range in Table 1. Table 1 Component measuring range /% F 50.00 ~ 68.00 Al 25.00 ~ 36.00 Na 0.020 ~ 10.00 SiO2 0.010 ~ 0.60 Component measuring range /% Fe2O3 0.010 ~ 0.50 SO2-4 0.10 ~ 2.00 P2O5 0.0020 ~ 0.30

2 principle of the method

Sample anhydrous lithium tetraborate and lithium metaborate mixed flux melted, add a small amount of lithium bromide (or iodide) as a release agent. In the melt prototype Melted into glass samples. Measured by X-ray fluorescence spectrometer. Theoretical coefficient α or fundamental parameter calibration between the absorbent element - Enhancement.

3 Reagents

3.1 anhydrous lithium tetraborate and lithium metaborate mixed flux [Li2B4O7 (67%) + LiBO2 (33%)]. at 700 ℃ burning 2h, dry place Dryer saved. 3.2 remover. a saturated solution of lithium bromide or ammonium iodide solution (300g/L). 3.3 Sample Monitoring. Monitor sample should be stable glass, contains all the elements of calibration, so that its content should be less than the statistical error count rate Or equal to the count rate calibration element statistical error.

4 Instrument

Platinum 4.1 - gold alloy crucible (95% Pt + 5% Au). 4.2 platinum - gold alloy casting (95% Pt + 5% Au). bottom mold material thickness of about 1mm, making it difficult to deformation. Note. The sample vessel melt casting mold can be combined. If the sample in the crucible directly after melt molding, the bottom surface of the inner wall of the crucible is required smooth. 4.3 fusion machine. automatic flame melt melting prototype prototype or high-frequency inductors, if other types of prototype melting temperature not lower than 1100 ℃, and can be controlled Temperature, temperature control accuracy of ± 15 ℃. 4.4 wavelength dispersive X-ray fluorescence spectrometer. end window rhodium anode X-ray tube.

5 Sample

The specimen shall conform YS/T 581.11 in 3.3 requirements.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YS/T 581.16-2008_English be delivered?

Answer: Upon your order, we will start to translate YS/T 581.16-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YS/T 581.16-2008_English with my colleagues?

Answer: Yes. The purchased PDF of YS/T 581.16-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.