YS/T 1065.1-2015 (YS/T1065.1-2015, YST 1065.1-2015, YST1065.1-2015) & related versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | See Detail | Status | Similar PDF |
YS/T 1065.1-2015 | English | 179 |
Add to Cart
|
3 days
|
Methods for physical performance determination of zeolite - Part 1: Determination of calcium binding capacity - EDTA titrimetric method
|
YS/T 1065.1-2015
| |
YST 1065.1-2015
|
YS/T 1065.1-2015
(Zeolite determination of physical performance - Part 1. Determination of calcium exchange capacity by titration with EDTA)
ICS 77.120.10
H21
People's Republic of China Nonferrous Metals Industry Standard
Zeolite determination of physical performance
Determination of calcium exchange capacity. Part 1
EDTA titration
Part 1. Determinationofcalciumbindingcapacity-
Issued on. 2015-04-30
2015-10-01 implementation
Ministry of Industry and Information Technology of the People's Republic of China released
Foreword
YS/T 1065-2015 "zeolite determination of physical performance" is divided into the following four parts.
--- Part 1. Determination of EDTA calcium exchange capacity of titration;
--- Part 2. Determination of particle size centrifugal sedimentation method;
--- Part 3. loss on ignition - Gravimetric method;
--- Part 4. Non-ionic liquid carrying capacity (LCC) measurement.
This is Part 1.
This section drafted in accordance with GB/T 1.1-2009 given rules.
The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) and focal points.
Drafting this Part. Aluminum Corporation of China Shandong Branch, China Aluminum Co., Ltd., Zhengzhou Light Metal Research Institute,
Shandong Liborihua Co., Ltd., Kunming Metallurgy Research Institute.
The main drafters of this section. Tian Rui, Li Jing, Wen Jinde, Wang Zheng, Xue Ning, Zhang Ping, Zhaode Ping.
Zeolite determination of physical performance
Determination of calcium exchange capacity. Part 1
EDTA titration
1 Scope
YS/T 1065 This section specifies the determination of calcium exchange capacity of the zeolite.
This section applies to the determination of calcium exchange capacity of the zeolite. Measurement range of 280mg/g ~ 320mg/g.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 8170 repair value represents about rules and limit values and judgment
YS/T 1065.3-2015 zeolite determination of physical performance - Part 3. loss on ignition - Gravimetric method
3 PRINCIPLE OF THE METHOD
4A zeolite Na can be replaced with Ca2 measuring Ca2 zeolite exchange capacity, in order to express 4A zeolite zeolite water softening
ability. Under certain conditions, zeolite and quantitative Ca2 adequate reaction solution, the filtrate was filtered, the remaining direct titration with EDTA standard solution
Remaining Ca2, to calculate the amount of zeolite for calcium exchange.
4 Reagents
4.1 Zinc oxide. the benchmark.
4.2 ammonia buffer solution. pH value of 10.
Weigh 54g ammonium chloride was added 350mL of aqueous ammonia (ρ = 0.9) was diluted with water to 1L, and mix.
4.3 Sodium hydroxide solution. 10g/L.
4.4 hydrochloric acid solution. 2.5mol/L.
4.5 chrome black T indicator. 5g/L.
4.6 ammonia solution. 110.
4.7 DETA Standard Solution (0.007133mol/L)
4.7.1 preparation
EDTA was previously dissolved in hot water, formulated as 7.5%. With cotton filter back. Pipette 365mL diluted to 10L.
4.7.2 Calibration
Weigh 0.2902g at (800 ± 50) ℃ in the high temperature furnace burning to a constant amount of zinc oxide (4.1), moist with a little water, add 3mL hydrochloric acid
Solution (4.4), transferred to 500mL volumetric flask. Dilute to volume, and mix. Take 20mL conical flask, add 70mL water, aqueous ammonia solution
(4.6) adjusted to pH 7 to 8, plus 10mL ammonia buffer solution (4.2), add 5 drops of chrome black T indicator (4.5), with EDTA standard drops
Fixed solution (4.7) calibration.
......
Standard ID | YS/T 1065.1-2015 (YS/T1065.1-2015) | Description (Translated English) | Methods for physical performance determination of zeolite. Part 1: Determination of calcium binding capacity. EDTA titrimetric method | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | Classification of Chinese Standard | H21 | Classification of International Standard | 77.120.10 | Word Count Estimation | 5,518 | Date of Issue | 2015-04-30 | Date of Implementation | 2015-10-01 | Quoted Standard | GB/T 8170; YS/T 1065.3-2015 | Drafting Organization | China Aluminum Co., Ltd. Shandong Branch, Aluminum Corporation of China Zhengzhou Light Metal Research Institute, Shandong Li Bo Daily Chemical Co., Ltd., Kunming Metallurgy Research Institute | Administrative Organization | National Non-Ferrous Metals Standardization Technical Committee (SAC/TC 243) | Regulation (derived from) | Ministry of Industry and Information Technology Announcement (2015 No. 28) | Proposing organization | National Non-Ferrous Metals Standardization Technical Committee (SAC/TC 243) | Issuing agency(ies) | Ministry of Industry and Information Technology of the People's Republic of China | Summary | This Standard specifies the determination of calcium exchange capacity of the zeolite. This Standard applies to the determination of calcium exchange capacity of the zeolite. Measurement range of 280 mg/g ~ 320 mg/g. |
|