TSG
SAFETY TECHNICAL SPECIFICATION OF SPECIAL EQUIPMENT
Pressure piping components type test regulation
Issued by: State Administration for Market Regulation
July 07, 2023
Table of Contents
Foreword ... 2
1 General provisions ... 5
2 Type test procedures and requirements ... 7
3 Supervision and administration ... 14
4 Supplementary provisions ... 16
Appendix A Type test product list of pressure piping component ... 18
Appendix B Type test application form of pressure piping component ... 21
Appendix C Type test items and their contents, methods and requirements of pressure
piping ... 22
Appendix D Type test items and their contents, methods, requirements for pressure
pipeline fittings ... 38
Appendix E Type test items and their contents, methods, requirements of pressure
pipeline valve ... 46
Appendix F Type test items and their contents, methods and requirements of pressure
pipeline flange ... 62
Appendix G Type test items and their contents, methods and requirements for pressure
piping compensator ... 64
Appendix H Type test items and their contents, methods and requirements for pressure
pipeline sealing element ... 71
Appendix J Type test items and their contents, methods and requirements for anti-
corrosion piping components of pressure pipelines ... 80
Appendix K Type test items and their contents, methods and requirements for pressure
piping component combination device ... 84
Appendix L Contact sheet for technical document review of pressure piping component
... 92
Appendix M Type test sampling sheet for special equipment ... 93
Appendix N Type test report of special equipment ... 94
Appendix P Type test certificate of special equipment (pressure piping components)
... 101
Pressure piping components type test regulation
1 General provisions
1.1 Purposes
In order to standardize the type test of pressure piping components, this “Regulation”
is formulated, in accordance with the "Special Equipment Safety Law of the People's
Republic of China", "Special Equipment Safety Supervision Regulations", as well as
other relevant laws and regulations.
1.2 Type test
Type test of pressure piping components (hereinafter referred to as type test) is carried
out by an approved inspection agency, that is responsible for type test (hereinafter
referred to as type testing agency), based on the quality inspection and test pass of the
pressure piping component manufacturer (hereinafter referred to as the manufacturer),
in accordance with the provisions of this “Regulation”, to verify its safety and reliability,
by checking whether the product complies with the safety technical specification,
through technical data review, safety performance inspection and test.
1.3 Scope of application
This “Regulation” applies to pressure piping components within the scope of the
"Special Equipment Catalog", which is used within the territory of the People's
Republic of China. For specific products, see Appendix A of this “Regulation”.
1.4 Type testing agency and type testing personnel
1.4.1 Type testing agency
(1) The type testing agency shall obtain corresponding qualifications and engage in
type testing within the approved scope;
(2) The type testing agency shall establish a quality management system and maintain
effective implementation;
(3) After receiving the type test application (or contract), the type testing agency shall
formulate a type test plan in a timely manner and notify the manufacturer to
prepare for the type test;
(4) The type testing agency shall provide the manufacturer with the type testing plan
and the qualifications of the type testing personnel;
(7) When new materials, new technologies, new processes used in manufacturing are
inconsistent with safety technical specifications or there are no requirements that
may have a significant impact on safety performance, review whether the
technical review has been passed and the corresponding approval procedures
have been performed.
2.5.3 Processing of review results
When the design documents and manufacturing process documents comply with
relevant safety technical specifications and the provisions of the based product
standards, the technical documents will be reviewed and determined to be in
compliance. When the technical document review fails to meet the requirements, the
type testing agency shall issue a "Contact sheet for review of technical documents of
pressure piping components" (see Appendix L, hereinafter referred to as "Contact
sheet"), to the manufacturer, to put forward written rectification opinions, AND confirm
the rectification actions of the manufacturer.
2.6 Sampling
2.6.1 Sampling method
Sampling methods shall meet the following requirements:
(1) Type test samples are selected by sampling personnel (type test personnel of the
type testing agency) from the finished product warehouse of the manufacturer
OR the products that have passed the exit-factory inspection and are waiting to
be put into the warehouse at the end of the production line, using random
sampling methods;
(2) Sampling personnel shall be familiar with the structure and manufacturing process
of the samples to be taken. There shall be no less than 2 sampling personnel;
they shall be separated from the personnel responsible for inspection and testing
(except for the items that can be inspected outside the sampling site, in
accordance with the provisions in Appendix C to Appendix K of this
“Regulation”);
(3) Sampling personnel shall verify the production equipment and testing equipment
of the main processes on site; confirm the consistency with the equipment list at
the time of application;
(4) When sampling, the sampling personnel shall review the technical documents,
production records, inspection records and reports of the type test samples; sign
and confirm the reviewed materials.
2.6.2 Sample sealing
After sampling, the sample shall be sealed and meet the following requirements:
(1) The sampling personnel shall fill in the "Special equipment type test sampling
form" (see Appendix M, hereinafter referred to as the "Sampling form"). The
sampling form shall be signed and chopped by both the sampling personnel and
the manufacturer;
(2) The sampling personnel shall seal the samples taken; if necessary, seal copies of
design documents, manufacturing process documents, sample inspection data,
etc., together with the samples;
(3) When samples need to be sent, the date and location of sample delivery shall be
indicated on the "Sampling form".
2.7 Inspection and testing of samples
2.7.1 Basic requirements
The inspection and testing of samples shall meet the following requirements:
(1) The type testing agency shall inspect and test the samples, in accordance with the
type testing plan. Unless otherwise provided in Appendixes C to K of this
“Regulation”, or unless special circumstances require the use of other
professional testing equipment, THEN, the inspection and testing shall be
carried out in the premises where the type testing agency conducts type
inspection and testing.
(2) The type testing agency can recognize the chemical composition and mechanical
properties of the raw materials provided by the manufacturer, as well as the
inspection and test results of non-destructive testing. When there is any doubt,
it shall be inspected and tested.
2.7.2 Test equipment and locations
Test equipment and locations shall meet the following requirements:
(1) Type testing agency need to prepare verification or calibration procedures for
inspection and testing equipment, to ensure that during the testing process, the
instruments and devices used for type testing have been verified or calibrated
and are within the validity period
(2) Control the places that affect the quality of inspection and testing; formulate safety
protection measures, to ensure that environmental conditions will not invalidate
or adversely affect the test results;
(3) Under special circumstances, when other professional test equipment is needed,
type test personnel shall confirm the test equipment; confirm the test process
and test data at the test site.
3 Supervision and administration
3.1 Certificate validity period
The type test certificate is valid for 4 years.
3.2 Certificate extension
3.2.1 Certificate extension application
Six months before the expiration of the type test certificate (and no more than 12
months), the manufacturer can apply for certificate extension to the prototype type
testing agency, by submitting a self-declaration letter of commitment and other
materials. The extension is valid for 4 years. The manufacturer shall not apply for type
test certificate extension twice in a row.
The self-declaration commitment letter of the manufacturer shall at least include its
commitment to comply with laws and regulations related to special equipment; a
description of compliance of resource conditions, production performance (the
production performance of each product during the certification period is no less than
5 batches), product safety performance status with relevant regulations; the description
of quality and safety consistency with the type test prototype (sample); a description of
the continuous and effective implementation of the quality management system; a
description of the absence of administrative penalties, liability accidents, equipment
safety performance issues, unsolved quality complaints related to special equipment.
The type testing agency shall complete the data review within 20 working days after
receiving the application data. If the data does not meet the requirements, it shall notify
the manufacturer in writing and explain the reasons. The certificate extension
conclusion is that it does not meet the requirements. If the data meets the requirements,
it shall formulate an on-site verification plan; notify the manufacturer in writing and
conduct on-site verification in a timely manner.
3.2.2 On-site verification
The type testing agency shall conduct on-site verification of the products, which are
manufactured within the validity period of the manufacturer's certificate, as well as the
technical documents and inspection data of products in manufacturing or in stock. If
necessary, it may conduct product exit-factory inspection at the manufacturer's site. The
main contents of the on-site verification are as follows:
(1) Randomly check whether the product is covered by the type test certificate
(2) Randomly check the compliance of the design, manufacturing process and other
information of the product with the type test report sample:
(3) Randomly check whether the main safety performance of the product is qualified.
The type testing agency shall notify the manufacturer in writing of the on-site
verification conclusions.
3.2.3 Approval of renewal of certificate
If the on-site verification concludes that the certificate is in compliance, the certificate
extension conclusion will be in compliance and a new type test certificate will be issued.
The validity period will be calculated from the expiration date of the original certificate.
If the on-site verification conclusion is non-compliance, the certificate extension
conclusion is non-compliance; it shall report to the provincial and prefecture-level
market regulatory authorities where the manufacturer is located in a timely manner.
3.3 Changes to type test certificates
3.3.1 Meaning of change
Certificate change means that during the validity period of the certificate, one of the
following situations occurs in the manufacturer:
(1) Change of organization name;
(2) Change of name of residence and manufacturing address (hereinafter collectively
referred to as address name change).
3.3.2 Change application
If a manufacturer changes its name or address, it shall submit a change application to
the prototype testing agency, within 30 working days after obtaining a new business
license from the market supervision and administration authority; meanwhile submit
the following materials:
(1) Application for change of special equipment type test certificate;
(2) Prototype test certificate (original);
(3) Business license before and after the change (when it cannot be verified online);
(4) Other materials that need explanation.
3.3.3 Certificate changes
The type testing agency shall make a decision on whether to approve the change within
20 working days from the date of receipt of the change application data. If the change
is approved, a new type test certificate will be issued and the original type test certificate
will be withdrawn. If the change is not approved, it shall notify the manufacturer in
written and describe the reasons.
Appendix C
Type test items and their contents, methods and requirements of pressure piping
C1 Seamless steel pipe
C1.1 Type test items
C1.1.1 Technical document review
(1) Quality control of raw materials (pipe blanks), including manufacturing standards,
manufacturing methods, acceptance requirements, etc.;
(2) Process documents such as steel pipe forming and heat treatment;
(3) Inspection and testing technology, including non-destructive testing, physical and
chemical testing, process performance testing, hydraulic testing, etc.
C1.1.2 Inspection and testing
(1) Appearance and geometric dimensions;
(2) Chemical composition;
(3) Mechanical properties, including tensile test, normal temperature impact test, low
temperature impact test (group IV materials in Table C-1), hardness test, etc.;
(4) Steel pipe process performance tests, including flaring tests, flattening tests,
bending tests, etc.;
(5) Metallographic examination, including low-magnification structure, grain size,
non-metallic inclusions, microstructure, etc.;
(6) Intergranular corrosion of stainless steel and pitting corrosion of duplex stainless
steel;
(7) Non-destructive testing or hydraulic testing;
(8) High-temperature tensile test, which has a temperature interval of 50 °C, within
the use temperature range (up to 50 °C exceeding the maximum allowable
operating temperature) (materials in groups II, III, V, VI in Table C-1), including
tensile strength, yield strength, elongation after fracture, reduction of area;
(9) Physical tests under simulated working conditions of threaded steel pipes for oil
and gas use, including shackle installation and removal tests, tensile to failure
tests, hydrostatic and internal pressure to failure tests, external pressure to failure
tests, air tightness tests (where applicable).
Note C-2: S and S* are respectively the nominal wall thickness of the sample and the
nominal wall thickness of the products within the coverage range. The same below.
C2.4 Test methods and acceptance requirements for main test items
C2.4.1 Steel pipe's resistance to large deformation test
C2.4.1.1 Longitudinal tensile test of steel pipe
Conduct longitudinal tensile tests on the steel pipe, before and after artificial aging
(heating temperature: 200 °C ± 5 °C; holding time: 5 min). Sampling and testing shall
be carried out, in accordance with the provisions of GB/T 228.1 "Metallic materials -
Tensile testing - Part 1: Method of test at room temperature". The test measurements
include but are not limited to the longitudinal yield strength (Rt0.5), tensile strength (Rm),
yield ratio (Rt0.5/Rm), stress ratio, uniform elongation (Agt), full tensile curve, etc., of
the steel pipe.
C2.4.1.2 Physical compression test of steel pipe
The length of the steel pipe for compression test shall not be less than 2.0 times the
nominal diameter; the two end faces of the pipe shall be parallel to each other and
perpendicular to the axis of the pipe. Before the test, measure the outer diameter and
wall thickness of the specimen; arrange strain gauges at specific positions (on steel pipe
busbars separated by 90° or 120°, arrange strain gauges at equal intervals along the
axial direction. The spacing shall be determined, based on the specific steel pipe size,
which is generally 1/5 to 1/2 of the radius of the steel pipe. In areas where buckling
may occur where strain is concentrated, the density of the arrangement of strain gauges
shall be appropriately increased). During the test, the loading rate of hydraulic
compression load is controlled below 20 mPa/s or 20 mm/min. Collect load, strain,
displacement throughout the process, to draw load-displacement and load-strain curves.
The maximum compressive strain of the buckling part at the moment of buckling is not
less than the design strain requirement.
C2.4.1.3 Physical bending test of steel pipe
The bending test is carried out, in accordance with the provisions of SY/T 7318.3 "Test
methods for special performance of oil and gas pipelines - Part 3: Full-size bending
test". The length of the specimen is not less than 6 times the nominal outer diameter of
the steel pipe; both ends are welded to the test nipple and sealed. Before the test,
measure the wall thickness and pipe diameter of the specimen. Arrange strain gauges at
specific positions (on steel pipe busbars separated by 30° or 45°, arrange strain gauges
at equal intervals along the axial direction. The spacing shall be determined, based on
the specific steel pipe size, which is generally 1/5 to 1/2 of the radius of the steel pipe.
In the middle of the bending compression side of the steel pipe, that is, the location
where the maximum compression deformation occurs, the arrangement density of the
strain gauges shall be appropriately increased). The test is carried out in a special
bending testing machine. Load, strain, displacement is collected throughout the test, to
draw the load-displacement and load-strain curves. The maximum compressive strain
of the buckling part at the moment of buckling is not less than the design strain
requirement.
C2.4.1.4 Longitudinal tensile test of steel pipe's butt girth weld
The length of the steel pipe for physical tensile test is not less than 2.0 times the nominal
diameter; the two end faces of the pipe are parallel to each other and perpendicular to
the axis of the pipe. The girth weld is placed in the middle of the specimen; defects of
specific sizes can be prefabricated as needed. During the test, it shall apply the tensile
loads controlled by internal pressure and displacement; it shall collect the data such as
load, displacement, crack opening, etc. The far-end strain corresponding to the load
drop, crack initiation, instability expansion, etc., can be used as the tensile strain
capability of the girth welded joint, as needed. The strain obtained by the physical
tensile test is not less than the design strain requirement, which is generally not less
than 0.5%.
C2.4.1.5 Wide plate tensile test of steel pipe's butt girth weld
The wide plate tensile test is carried out, in accordance with the provisions of SY/T
7318.1 "Standard test method for special properties of line pipe - Part 1: Curved wide
plate tensile testing". The width within the gauge length of the specimen shall not be
less than 300 mm (in cases where the outer diameter is less than 800 mm, it may be
specified separately), the length of the specimen shall not be less than 4 times the width.
Placing the girth weld in the middle of the specimen can prefabricate defects of specific
sizes as needed. During the test, it shall apply a displacement-controlled tensile load;
collect the data such as load, displacement, crack opening. The far-end strain of the pipe
corresponding to the load drop, crack initiation, instability expansion, etc. can be used
as the tensile strain capability of the girth welded joint, as needed. The tensile strain,
which is determined by the wide plate tensile test, is not less than the design strain
requirement, which is generally not less than 0.5%.
C2.4.2 Physical test under simulated working conditions
Same as Article C1.4.2 of this “Regulation”.
C3 Nonferrous metal pipe
C3.1 Type test items
C3.1.1 Technical document review
(1) The process documents of forming, welding, heat treatment of non-ferrous metal
pipe;
(2) Inspection and testing processes, including non-destructive testing, physical and
limit.
b) Welded pipe
Materials of the same base metal category in NB/T 47014 "Welding procedure
qualification for pressure equipment" can cover each other.
(3) Specification coverage
a) Seamless pipe
When 50 mm ≤ DN < 150 mm, 50 mm ≤ DN* < 150 mm;
When DN ≥ 150 mm, 150 mm ≤ DN* < DN.
b) Welded pipe
Large wall thicknesses can cover small wall thicknesses.
0.5S/DN ≤ S*/DN* ≤ 3S/DN.
C4 Ductile iron pipe
C4.1 Type test items
C4.1.1 Technical document review
(1) Process documents for ductile iron pipe casting, heat treatment, coating, etc.;
(2) Inspection and testing technology, including mechanical property testing, pressure
testing, sealing testing, etc.
C4.1.2 Inspection and testing
(1) Appearance and geometric dimensions (including coating layer);
(2) Tensile test;
(3) Brinell hardness;
(4) Metallographic examination (when applicable);
(5) Pressure test;
(6) Air tightness test;
(7) Interface sealing test.
Appearance and geometric dimensions, pressure test, air tightness test, interface sealing
test can be conducted at the manufacturer's premises.
of lined composite steel pipe);
(6) Hydrostatic pressure test;
(7) Intergranular corrosion test (when applicable);
(8) Non-destructive testing.
Appearance, geometric dimensions, non-destructive testing, hydrostatic test items can
be carried out at the manufacturer's premises.
Note C-3: If the base pipe and liner pipe for manufacturing lined composite steel pipes have
completed chemical composition and mechanical property tests before compositing, the
relevant reports can be confirmed. For inner cladding composite steel pipes manufactured using
the surfacing process, it may be exempted from the shear strength test. For lined composite
steel pipes manufactured using hydraulic composite technology, it may be exempted from the
hydrostatic tests.
C5.2 Sampling rules
Same as item 2.4.3(2) of this “Regulation”.
C5.3 Coverage range
Coverage range shall meet the following conditions at the same time:
(1) Manufacturing process coverage
The manufacturing process of lined composite steel pipes includes hydraulic,
deflagration, spinning and other mechanical composite processes; the
manufacturing process of inner cladding composite steel pipes includes composite
steel plate forming welding, base pipe inner surface surfacing, hot rolling, hot
extrusion (including hot isostatic pressing), explosive compositing, powder
metallurgy or other metallurgical composite processes. Different composite
processes cannot cover each other.
(2) Material coverage
The lining and inner cladding materials include stainless steel, duplex stainless
steel and nickel-based alloys. Duplex stainless steel can cover stainless steel;
nickel-based alloy can cover stainless steel and duplex stainless steel.
(3) Specification coverage
When 50 mm ≤ DN < 300 mm, 50 mm ≤ DN* < 300 mm;
When DN ≥ 300 mm, 300 mm ≤ DN* ≤ DN.
......
TSG
Special Equipment Safety Technical Regulation
Pressure Piping Components Type Test
Regulation
Issued by General Administration of Quality Supervision, Inspection
and Quarantine of the People's Republic of China
October 27, 2006
Contents
Pressure Piping Components Type Test Regulation ... 1
Appendix A ELementary Items and Requirements of Pressure Piping Components Type Test
... 4
Appendix B Items, Contents, Methods and Requirements of Type Test on Typical Metallic
Pressure Piping Components ... 10
Appendix C Items, Contents, Methods and Requirements of Type Test on Typical Nonmetallic
Pressure Piping Components ... 33
Appendix D Items, Contents, Methods and Requirements of Type Test on Typical Pressure
Piping Metal Valve Products ...48
Appendix E Items, Contents, Methods and Requirements of Type Test on Typical Pressure
Piping Compensators ... 58
Appendix F Items, Contents, Methods and Requirements of Typical Type Test on Pressure
Piping Sealing Components ... 67
Appendix G Items, Contents, Methods and Requirements of Type Test on Typical Anti-
corrosive Pressure Piping Components ... 71
Appendix H Items, Contents, Methods and Requirements of Type Test on Special Steel
Plate and Steel Band for Manufacturing Pressure Pipes ... 79
Appendix I Items, Contents, Methods and Requirements of Type Test on Polyethylene (PE)
Raw Material ... 81
Appendix J Special Equipment Type Test Report ... 82
Appendix K Special Equipment Type Test Certificate ... 89
Appendix L Summary Statement of Pressure Piping Components Type Test ... 91
Pressure Piping Components Type Test Regulation
1 This regulation was formulated according to the "Regulation on Safety Supervision of
Special Equipment" (hereinafter referred to as "Regulation") with a view to specifying the
pressure piping components type test work and ensuring the manufacturing quality of pressure
piping components.
2 The pressure piping components type test specified in this regulation is the technical
document examination, specimen inspection and test as well as safety feature test conducted
in order to verify whether the product safety meets the safety technical requirements.
3 For all the pressure piping components applied in the People's Republic of China and
meeting the application scope of ''Regulation", their type test shall meet those specified in this
regulation, and their safety performances shall meet the relevant safety technique
specifications and the basic requirements specified in corresponding standards. In principle,
the safety performances of the imported pressure piping components shall not be less than the
basic requirements on safety performances of the pressure piping components in China.
This regulation excludes the type test of safety valves.
4 The pressure piping components type test shall be carried out by the Type Test Institutions
that are authorized by the General Administration of Quality Supervision, Inspection and
Quarantine. The Type Test Institution shall carry out the pressure piping components type test
within its authorized scope.
5 After accepting the type test invitation of the pressure piping components manufacturing
organization or its entrusted import commission agent, the pressure piping components type
test institution shall develop the type test scheme according to those specified in the relevant
appendix in this regulation, and also shall inform the specific testing time.
6 The manufacturing organization of pressure piping components ot its entrusted import
commission agent shall provide the following data when applying for the type test to the Type
Test Institution.
(1) Name and address of the manufacturing organization (the import commission agent
still shall provide its name and address);
(2) Name, specification scope, technical parameter as well as the accepted standards of
the products applying for type test;
(3) Written statement on not reporting the same application to any other type test
institutions in the past;
( 4) Other data including the design documents needed in the type test.
7 The pressure piping components type test includes the design examination (including the
design documents and manufacture technological documents) and the specimen (test sample)
inspection and test.
The type test procedures include design review, extracting test specimens (test samples),
inspection and test, management of test specimens, issuing type test report and type test
certificate.
See Appendix A for the elementary items and requirements of type test, and see
Appendixes B~I for the the items, contents, methods and requirements of the type tests on
typical products.
Appendixes B~I in this regulation cover the basic requirements on the type test of of the
typical products of pressure piping components, the Type Test Institution shall formulate
detailed type test scheme aiming at specific product structures.
8 The pressure piping components meeting one of the following conditions shall be carried
out with type test.
(1) The manufacturing organization manufactures the typical pressure piping components
specified in Appendixes B~I of this regulation for the first time or for addtional projects;
(2) The manufacturing of pressure piping components is allowed to adopted type test
method;
(3) Requirement specified in the safety technique specifications.
9 The pressure piping components type test shall cover certain range of products in different
test units. The test units shall be divided according to the process function, manufacture
process, design method, structural style and failure mode of the pressure piping components,
ans please see Appendiexes ~I for the range of products covered by the pressure piping
components type test.
10 The Type Test Institution shall carry out inspection and test on the specimens (test
samples) as required. The inspecters and testers shall be responsible for the correctness of the
inspection and test results, anyone shall not fabricate or distort the inspection and test results.
Except for those inspection and test that must be carried out at the sampling site or need
special professional equipments, the test shall be carried out in the test and inspection sites of
the Type Test Institution.
11 After completing the type test, the Type Test Institution shall summarize the data timely
and issue the type test report and certificate (see Appendix J and Appendix K for specific
formats and contents) to its client. If the products are rejected in the type test, the Type Test
Institution still shall report the type test report to the examination and approval authority that
authorizes the manufacturing of pressure piping components.
The Type Test Institution shall keep the relevant original records of type test and the type
test report for a long term.
The Type Test Institution shall fill in the "Summary Statement of Pressure Piping
Components Type Test" (see Appendix L) of the current year to the General Administration of
Quality Supervision, Inspection and Quarantine at the end of one year annually.
12 The type test shall be carried out again when any one of the following conditions is met.
Appendix A ELementary Items and Requirements of Pressure
Piping Components Type Test
Al Design review
The design review includes the examinations on design documents and manufacture
technological documents. As for the pipes, pipe fittings and potted components for the
pressure pipes specified in the national standards, their design documents may not be
examined.
Al.1 Design document examination
The broad contents and requirements of design document examination are as follows.
(1) Whether the design documents such as design drawings and design calculation
sheet are intact, whether the calculation methods adopted in the design are right, and whether
the design data and their sources are approciate;
(2) Whether the structure design that influences the safety performances of products
meets those specified in the technical regulations and standards;
(3) If necessary, the confirmatory calculation shall be conducted so as to determine
whether the design of sampled products has any defects that may impact the safety
performances.
When the relevant safety technique specifications or standards cover no corresponding
structural shapes or design calculation methods on the products produced by the manufacturing
organization, the manufacturing organization shall provide the operating principle introductions
of its products or explanations of design calculation method in its design calculation sheet that
are submitted for examination.
Al.2 .Manufacture technological document examination
The broad contents of examination include whether the manufacture process of the major
production procedures of products meets those specified in the relevant safety technique
specifications and standards and whether the acceptance requirements of products meet the
specifications.
Al.3 Examination result reduction
After the design review, the Type Test Institution shall timely communicate with the
manufacturing organization. When the design documents and manufactur technological
documents fail to meet the relevant provisions, the Type Test Institution shall propose its
correction opinions in written form to the manufacturing organization and also shall confirm
the correction conditions of manufacturing organization.
A2 Sampling
A2.1 Sampling method
A3.3 Testers
The Type Test Institution shall ensure rhw operators of special equipments and the
inspecters and testers be with the corresponding abilities and qualifications.
A3.4 Test equipments and test sites
The test equipments and sites shall meet the following requirements.
(1)...
......
Standard ID | TSG D7002-2023 (TSGD7002-2023) | Description (Translated English) | Pressure Piping Components Type Test Regulation | Sector / Industry | Special Equipment Industry Standard | Word Count Estimation | 76,765 | Date of Issue | 2023-07-07 | Date of Implementation | 2023-10-01 | Summary | This standard applies to pressure piping components within the scope of the "Special Equipment Catalogue" used in the territory of the People's Republic of China. For specific products, see Appendix A of this standard. | Standard ID | TSG D7002-2006 (TSGD7002-2006) | Description (Translated English) | Pressure Piping Components Type Test Regulation [Quasi-Official / Academic version - scanned PDF, translated by Standard Committee / Research Institute in China] | Sector / Industry | Special Equipment Industry Standard | Classification of Chinese Standard | J74 | Classification of International Standard | 23.020.30 | Word Count Estimation | 86,872 | Date of Issue | 2006-10-27 | Date of Implementation | 2006-10-27 | Drafting Organization | Jiangsu Province Special Equipment Safety Supervision Inspection Institute | Administrative Organization | ?PRC AQSIQ | Regulation (derived from) | ?AQSIQ Announcement 2006 No.163 | Summary | This standard specifies the type test pressure piping components-verification of product safety performance meets safety requirements, technical document review, sample inspection testing and safety performance test. This rule does not include a safety valve type test. |
|