HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (12 Oct 2024)

SN/T 2210-2021 related PDF English (SNT2210-2008)

SN/T 2210-2021 (SN/T2210-2021, SNT 2210-2021, SNT2210-2021) & related versions
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusSimilar PDF
SN/T 2210-2021English245 Add to Cart 0-9 seconds. Auto delivery. Determination of hexavalent chromium in foods for export SN/T 2210-2021 Valid SNT 2210-2021
SN/T 2210-2008English719 Add to Cart 3 days Determination of hexavalent chromium in health foods. IC-ICP-MS method SN/T 2210-2008 Obsolete SNT 2210-2008
Buy with any currencies (Euro, JPY, KRW...): SN/T 2210-2021    Preview this PDF: SN/T 2210-2021



SN/T 2210-2021 SN ENTRY-EXIT INSPECTION AND QUARANTINE INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 67.050 CCS X 04 Replacing SN/T 2210-2008 Determination of hexavalent chromium in foods for export ISSUED ON: NOVEMBER 22, 2021 IMPLEMENTED ON: JUNE 01, 2022 Issued by: General Administration of Customs of the People's Republic of China Table of Contents Foreword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Terms and definitions ... 4 4 Method summary ... 4 5 Reagents and materials ... 4 6 Instruments and equipment ... 5 7 Specimen preparation and storage ... 6 8 Determination steps ... 6 9 Result calculation and expression ... 7 10 Limit of quantitation, recovery rate and precision ... 8 11 Method summary ... 8 12 Reagents and materials ... 8 13 Instruments and equipment ... 9 14 Sample preparation and storage ... 9 15 Determination steps ... 9 16 Result calculation and expression ... 10 17 Limit of quantitation, recovery and precision ... 11 Annex A (informative) Working conditions of inductively coupled plasma mass spectrometry ... 12 Annex B (informative) Standard solution chromatogram ... 13 Annex C (informative) Addition recovery rate and precision of hexavalent chromium in different samples (n=6) ... 14 Determination of hexavalent chromium in foods for export 1 Scope This document specifies the determination method for hexavalent chromium in foods for export. This document is applicable to the determination of hexavalent chromium in health foods, cereals, vegetables, meat, aquatic products, candy and other foods. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 6682, Water for analytical laboratory use -- Specification and test methods 3 Terms and definitions There are no terms or definitions to be defined in this document. Method One -- High performance liquid chromatography-inductively coupled plasma mass spectrometry 4 Method summary The chromate ions (CrO42-) in the sample are extracted using dipotassium hydrogen phosphate buffer solution (0.1 mol/L) with a pH of 7.9~8.1. After high-speed centrifugation, it is passed through a 0.45 μm filter membrane for high-performance liquid chromatography-inductively coupled plasma mass spectrometry measurement. Quantify by external standard method. 5 Reagents and materials Unless otherwise stated, all reagents used are analytically pure, and the water is grade one water specified in GB/T 6682. 5.1 Nitric acid (p=1.42 g/mL): guaranteed reagent. 5.2 Dipotassium hydrogen phosphate. 5.3 Ammonia. 5.4 n-Hexane. 5.5 Dipotassium hydrogen phosphate buffered extraction solution (0.1 mol/L): Dissolve 22.822 g of dipotassium hydrogen phosphate in water. Add nearly 1000 mL of water. Mix well. Use phosphoric acid solution or potassium hydroxide solution to adjust the pH to pH 7.9 ~8.1. Set the volume to 1000 mL. 5.6 Hexavalent chromium standard solution: 100 mg/L hexavalent chromium standard solution. It is certified reference material. 5.7 Hexavalent chromium standard stock solution: Dilute the hexavalent chromium standard stock solution with water step by step to a 100 μg/L solution. Prepare when needed. 5.8 Hexavalent chromium standard curve solution: Pipette 0 mL, 0.125 mL, 0.5 mL, 1.25 mL, 2.5 mL, and 5 mL of standard stock solution (5.7) into 25 mL volumetric flasks. Set the volume up to the mark with water. Mix well. The standards of this standard series are: 0 μg/L, 0. 5 μg/L, 2 μg/L, 5 μg/L, 10 μg/L, and 20 μg/L. Prepare when needed. 5.9 Mobile phase (56 mmol/L nitric acid-67 mmol/L ammonia, pH 9.0): Accurately pipet 2.00 mL of nitric acid and 2.50 mL of ammonia solution into a beaker. Add nearly 500 mL of water. Mix well. Adjust the pH to 9.0 with ammonia or nitric acid solution, and transfer it to a 500 mL volumetric flask. Set the volume to the mark with water. Conduct ultrasonic degassing for 10 min. 6 Instruments and equipment 6.1 High performance liquid chromatography-inductively coupled plasma mass spectrometer. 6.2 Ultrasonic generator. 6.3 Vortex mixer. 6.4 Oscillator. 6.5 Refrigerated centrifuge: the rotation speed is greater than 10000 r/min; the minimum temperature is less than 4℃. 6.6 Analytical balance: sensitivity is 1 mg. 7 Specimen preparation and storage 7.1 Specimen preparation Take about 500 g of representative sample from all the samples taken. Grind solid samples to powders. Those with high moisture content are beaten into a paste. Mix well. Divide into two equal portions. Put them into clean containers separately. Seal them as specimens. Indicate the mark. For health care capsule samples, discard the capsule shell and remove the entire contents. 7.2 Specimen storage Specimens with high moisture content shall be frozen and stored below -18°C. 8 Determination steps 8.1 Sample processing Weigh 0.5 g of powder sample and 0.5 g~1.0 g (accurate to 0.001 g) of the sample with high moisture content in a 50 mL centrifuge tube. Add dipotassium hydrogen phosphate extraction solution (5.5). Dilute to 25 mL. The sample is vortexed for 2 min, ultrasonic extracted for 20 min, extracted on a shaking table for 30 min, and centrifuged at 10000 r/min for 5 min. Take 4 mL of the supernatant into a 15 mL centrifuge tube. Add 1 mL of n-hexane. Then conduct high-speed centrifugation at 10000 r/min for 5 min. Remove 2 mL of supernatant. Pass through a 0.45 μm aqueous phase filter membrane and wait for measurement on the machine. Complete the measurement within 2 h. 8.2 Determination 8.2.1 Liquid chromatography reference conditions Liquid chromatography reference conditions are listed below: a) Chromatographic column: anion exchange column, 250 mm × 4.1 mm (inner diameter), 10 μm, or one with equivalent performance. b) Mobile phase: 56 mmol/L nitric acid-67 mmol/L ammonia, pH 9.0 (5.9). c) Flow rate: 1.0 mL/min. d) Injection volume: 50 μL. 8.2.2 Inductively coupled plasma-mass spectrometry conditions 10 Limit of quantitation, recovery rate and precision 10.1 Limit of quantification (LOQ) The limit of quantitation of this method is 0.05 mg/kg. 10.2 Recovery rate and precision The recovery and precision results of this method at the added concentration are shown in Table C.1. Method Two -- Ion chromatography post-column derivatization 11 Method summary Use dipotassium hydrogen phosphate buffer solution (0.1 mol/L) with pH 7.9~8.1 to extract chromate ions (CrO42-) in the specimen. After high-speed centrifugation, the extract is filtered through a 0.45 μm filter. Interfering substances are separated by ion chromatography. Mix with derivatization reagent (diphenylcarbazide). Utilizing the strong oxidizing property of chromate, diphenylcarbazide is oxidized in an acidic environment and complexed into a purple-red complex. The absorbance is measured at 540 nm. Use external standard method to quantify. 12 Reagents and materials Unless otherwise stated, all reagents used are analytically pure, and the water is grade one water specified in GB/T 6682. 12.1 Nitric acid (p =1.42 g/mL): guaranteed reagent. 12.2 Dipotassium hydrogen phosphate. 12.3 Ammonia. 12.4 n-Hexane. 12.5 Methanol: chromatographically pure. 12.6 Sulfuric acid (p =1.84 g/mL). 12.7 Diphenylcarbohydrazide: chromatographically pure. 12.8 Dipotassium hydrogen phosphate buffer solution (0.1 mol/L): see (5.5). 12.9 2 mol/L sulfuric acid solution: Measure 108.7 mL of concentrated sulfuric acid. Slowly transfer into a beaker containing approximately 800 mL of water. Stir constantly while doing so. After the solution cools to room temperature, transfer it to a 1000 mL volumetric flask. Add water to the mark. 12.10 Post-column derivatization solution: Weigh 0.4 g of diphenylcarbazide. Dissolve with 50 mL of methanol. Transfer to a 500 mL volumetric flask. Measure 50 mL of 2 mol/L sulfuric acid and add it to the 500 mL volumetric flask. Shake well. Add water to set the volume to the mark. 12.11 Hexavalent chromium standard solution: 100 mg/L hexavalent chromium standard solution. It is certified reference material. 12.12 Hexavalent chromium standard stock solution: see (5.7). 12.13 Hexavalent chromium standard curve solution: see (5.8). 12.14 Mobile phase: Accurately pipet 2.5 mL of nitric acid and 3.5 mL of ammonia solution into a 500 mL volumetric flask. Use water to set the volume to the mark. Conduct ultrasonic degassing for 10 min. 13 Instruments and equipment 13.1 Ion chromatograph with post-column derivatization device, diode array or UV- visible detector. 13.2 Ultrasonic generator. 13.3 Vortex mixer. 13.4 Oscillator. 13.5 Refrigerated centrifuge: the rotation speed is greater than 10000 r/min; the minimum temperature is less than 4℃. 13.6 Analytical balance: sensitivity is 1 mg. 14 Sample preparation and storage See Chapter 7. 15 Determination steps 15.1 Sample processing See 8.1. ......

BASIC DATA
Standard ID SN/T 2210-2021 (SN/T2210-2021)
Description (Translated English) Determination of hexavalent chromium in foods for export
Sector / Industry Commodity Inspection Standard (Recommended)
Classification of Chinese Standard X04
Classification of International Standard 67.050
Word Count Estimation 12,169
Date of Issue 2021-11-22
Date of Implementation 2022-06-01
Older Standard (superseded by this standard) SN/T 2210-2008
Drafting Organization Shanghai Customs, Tianjin Customs, Guangzhou Pu Linsheng Technology Co., Ltd., etc.
Administrative Organization General Administration of Customs of the People's Republic of China
Regulation (derived from) General Administration of Customs Announcement No. 97 of 2021
Proposing organization Shanghai Customs, Tianjin Customs, Guangzhou Pu Linsheng Technology Co., Ltd., etc.
Issuing agency(ies) General Administration of Customs

BASIC DATA
Standard ID SN/T 2210-2008 (SN/T2210-2008)
Description (Translated English) Determination of hexavalent chromium in health foods. IC-ICP-MS method
Sector / Industry Commodity Inspection Standard (Recommended)
Classification of Chinese Standard X04
Word Count Estimation 18,149
Date of Issue 2008-11-18
Date of Implementation 2009-06-01
Drafting Organization China Shanghai Entry-Exit Inspection and Quarantine Bureau picking
Administrative Organization National Certification and Accreditation Administration Committee
Regulation (derived from) National Quality Inspection [2008] No. 577
Proposing organization National Certification and Accreditation Administration Standardization Committee
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Summary This standard specifies the health food hexavalent chromium ion chromatography inductively coupled plasma mass spectrometry. This standard applies to hypoglycemic milk, nutritional supplements, health drinks Determination of hexavalent chromium.

BASIC DATA
Standard ID ()
Description (Translated English) (Technical specifications for ceramic capacitive sensor type partial discharge monitoring devices of 35kV and below)
Sector / Industry Chinese Industry Standard
Date of Issue 2023-10-11
Date of Implementation 2024-04-11
Issuing agency(ies) National Energy Board