| US$174.00 · In stockDelivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
 SN/T 1800-2006: Microbiology of food and animal feeding stuffs. Colony-count method at 30 Celsius
 Status: Valid
 
	
		
			| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |  
			| SN/T 1800-2006 | English | 174 | Add to Cart | 3 days [Need to translate] | Microbiology of food and animal feeding stuffs. Colony-count method at 30 Celsius | Valid | SN/T 1800-2006 |  
	 
       PDF similar to SN/T 1800-2006 
 Basic data             | Standard ID | SN/T 1800-2006 (SN/T1800-2006) |           | Description (Translated English) | Microbiology of food and animal feeding stuffs. Colony-count method at 30 Celsius |           | Sector / Industry | Commodity Inspection Standard (Recommended) |           | Classification of Chinese Standard | C53 |           | Classification of International Standard | 07.100.30 |           | Word Count Estimation | 9,993 |           | Date of Issue | 2006-08-28 |           | Date of Implementation | 2007-03-01 |           | Quoted Standard | SN/T 1538.1-2005; ISO 6887; ISO 7218: 1996; ISO 8261 |           | Adopted Standard | ISO 4833-2003, IDT |           | Issuing agency(ies) | General Administration of Customs |           | Summary | This standard specifies the need to raise at 30��C cultured on solid medium colony counting method. This standard applies to human food and animal feed. This standard does not apply to testing fermented food and animal feed. | SN/T 1800-2006: Microbiology of food and animal feeding stuffs. Colony-count method at 30 Celsius---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
 Microbiology of food and animal feeding stuffs.Colony-count method at 30 Celsius
Book of the People's Republic of China Entry and Exit Inspection and Quarantine
SN/T 1800-2006/ISO 4833.2003
Food and animal feed microbiology
30 ° C colony counting method
(ISO 4833.2003 Microbiologyoffoodandanimalfeedingstuffs-
Colony-counttechniqueat30°C, IDT)
Released on.2006-08-28
2007-03-01 implementation
People's Republic
The General Administration of Quality Supervision, Inspection and Quarantine issued
 ForewordThis standard is equivalent to ISO 4833.2003 "Food and animal feed microbiology --- microbial 30 ° C colony counting method" (English
Text version).
For ease of use, this standard makes the following editorial changes.
a) replace “this International Standard” with “this standard”;
b) Replace the decimal point symbol "," with the decimal symbol ".";
c) Remove the preface to international standards.
Appendix A of this standard is an informative annex.
This standard is proposed and managed by the National Certification and Accreditation Administration.
This standard was drafted. Henan Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China, China National Laboratory Accreditation Committee.
The main drafters of this standard. Li Zhipei, Li Hong, Jiang Zhiyi, Qiao Qing, Yang Xiangying, Miao Li.
This standard is the first industry standard for entry-exit inspection and quarantine.
SN/T 1800-2006/ISO 4833.2003
Food and animal feed microbiology 30 ° C colony counting method1 ScopeThis standard specifies colony counting methods on solid medium cultured at 30 °C in aerobic conditions.
This standard applies to human food and animal feed. This standard does not apply to the detection of fermented food and animal feed.2 Normative referencesThe terms in the following documents become the terms of this standard by reference to this standard. All dated references, followed by all
Modifications (not including errata content) or revisions do not apply to this standard. However, parties to agreements based on this standard are encouraged to
Whether the latest version of these files can be used. For undated references, the latest edition applies to this standard.
Preparation of medium for the preparation of SN/T 1538.1-2005 Part 1. Preparation of laboratory preparations
(ISO /T S11133-1.2000, MOD)
ISO 6887 (all parts) Food and animal feed microbiology - preparation of microbiological test samples, initial suspension and ten times
Diluent
ISO 7218.1996 Food and animal feed microbiology -- General rules for microbiological testing
ISO 8261 Milk and dairy products -- General guidelines for the preparation of microbiological test samples, initial suspensions and ten-fold dilutions3 Terms and definitionsThe following terms and definitions apply to this standard.
3.1
Bacteria, yeasts and molds that count colonies are formed under the conditions specified in this standard.4 Principle4.1 If the product is a liquid, prepare two pouring plates with the specified medium and a specified amount of sample, if other products are used
Amount of initial suspension preparation.
Another pair of poured plates were prepared under the same conditions using a ten-fold diluted test sample or initial suspension.
4.2 Place the plate at 30 ° C for 72 h aerobic incubation.
4.3 Calculate the number of colonies on the selected plate to obtain the number of microorganisms per milliliter or per gram of sample (see Chapter 10).5 medium and dilutionFor general laboratory operations see ISO 7218 and SN/T 1538.1-2005.
5.1 dilution
See the relevant part of ISO 6887.
5.2 Plate Count Agar (PCA)
5.2.1 Composition
Enzymatically hydrolyzed casein 5.0g
Yeast Extract 2.5g
SN/T 1800-2006/ISO 4833.2003
 
 Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of SN/T 1800-2006_English be delivered?Answer: Upon your order, we will start to translate SN/T 1800-2006_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of SN/T 1800-2006_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 1800-2006_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries Question 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected] . In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.    |