US$179.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. QB/T 4096.24-2024: (Performance of room heaters for household and similar purposes - Part 24: Special requirements for liquid-filled heaters) Status: Valid QB/T 4096.24: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
QB/T 4096.24-2024 | English | 179 |
Add to Cart
|
3 days [Need to translate]
|
(Performance of room heaters for household and similar purposes - Part 24: Special requirements for liquid-filled heaters)
| Valid |
QB/T 4096.24-2024
|
QB/T 4096.24-2011 | English | 130 |
Add to Cart
|
0--9 seconds. Auto-delivery
|
Performance of Room Heaters for Household and Similar Purposes - Part 24: Particular Requirements for Liquid-filled Radiators
| Obsolete |
QB/T 4096.24-2011
|
Basic data Standard ID | QB/T 4096.24-2024 (QB/T4096.24-2024) | Description (Translated English) | (Performance of room heaters for household and similar purposes - Part 24: Special requirements for liquid-filled heaters) | Sector / Industry | Light Industry Standard (Recommended) | Classification of Chinese Standard | Y63 | Classification of International Standard | 97.100.10 | Word Count Estimation | 8,860 | Date of Issue | 2024-03-29 | Date of Implementation | 2024-10-01 | Issuing agency(ies) | Ministry of Industry and Information Technology | Summary | This standard specifies the requirements for appearance, corrosion resistance, safety, electromagnetic compatibility, length of power cord, low temperature and low voltage start-up, heating effect, effective power, heating time, cooling, anti-freezing temperature, impact current, noise power level, durability, safe service life, standby power, humidification capacity, and mechanical properties of casters related to the performance of liquid-filled heaters for household and similar purposes. It describes the corresponding test conditions and test methods, specifies the inspection rules, marking, packaging, transportation and storage content, and gives product classifications that are convenient for technical regulations. This standard applies to the production, testing and sales of heaters related to the rated voltage of single-phase appliances not exceeding 250V and the rated voltage of other appliances not exceeding 480V. This standard does not apply to:, installed in the structure of a building. |
QB/T 4096.24-2011
QB
LIGHT INDUSTRY STANDARD OF
THE PEOPLE’S REPUBLIC OF CHINA
ICS 97.100.10
Y 63
Record No.. 34991-2012
Performance of Room Heaters for Household and Similar Purposes
- Part 24. Particular Requirements for Liquid-filled Radiators
ISSUED ON. DECEMBER 20, 2011
IMPLEMENTED ON. JULY 1, 2012
Issued by. Ministry of industry and information technology of the People's
Republic of China
3. No action is required - Full-copy of this standard will be automatically &
immediately delivered to your EMAIL address in 0~60 minutes.
Table of ContentsForeword ... 3
1 Scope ... 4
2 Normative References ... 4
3 Terms and Definitions ... 4
4 Production Classification ... 5
5 Requirements ... 6
6 Test methods ... 7
7 Inspection Rules ... 11
8 Marking, Packaging, Transportation and Storage ... 12
Appendix ... 13
Appendix AA (Informative) The Effect Sketch of Climate Laboratory ... 13
ForewordQB/T 4096 is the first part of the series of standards for the performance of room
heaters for household and similar purposes; and It is the general requirements part.
This Part is QB/T 4096.24-2011, Performance of Room Heaters for Household and
Similar Purposes - Part 24. Particular Requirements for Liquid-filled Radiators.
This Part should be used together with QB/T 4096-2010, Performance of Room
Heaters for Household and Similar Purposes - Part 1. General Requirements.
This part is formed by modification or addition of QB/T 4096-2010. Where it states
"applicable", it means that the corresponding provisions in QB 4096-2010 apply to this
part; where it states "replacement", it means that the provisions in this part shall prevail;
where is states “modification”, it means that the modified content of the related
provisions in the corresponding clauses of QB/T 4096-2010 shall prevail, and the rest
content of the clause is still applicable; where it states “addition”, it means that the
additional provisions in this part shall, at the same time, meet the related provisions in
QB/T 4096-2010.
The additional provisions to QB/T 4096 are numbered from 101.
This Part was proposed by the China Light Industry Federation.
This Part shall be under the jurisdiction of the National Household Electrical
Standardization Technical Committee (SAC/TC46).
The responsible drafting organizations of this Part. Singfun Group Co., Ltd., Ningbo
Singfun Electrical Manufacturing Co., Ltd., Guangdong Midea Environmental Electrical
Manufacturing Co., Ltd.
The participating drafting organizations of this Part. China Institute of Electrical
Appliances, Ningbo Product Quality Supervision and Inspection Institute, China
Electrical Science Research Institute, Zhejiang Quality and Technical Supervision and
Inspection Institute, Guangzhou Vkan Certification and Testing Co. Ltd., China National
Supervision and Test Center for Infrared and Industry Galvanothermy Product Quality.
The main drafters of this Part. Fang Qingzhen, Zhu Yongguo, Nie Yong, Ma Dejun, Bao
Jun, Xu Yanrong, Zhao Qi, Su Tao, Chen Yonghua, Zeng Yu.
Performance of Room Heaters for Household and Similar Purposes
- Part 24. Particular Requirements for Liquid-filled Radiators
ScopeThis chapter of QB/T 4096-2010 is replaced by the following contents.
This Part specifies the terms and definitions, product classification, requirements,
testing methods, inspection rules, and marking, packaging, transportation and storage
of liquid-filled radiators for household and similar purposes (hereinafter “radiators”).
This Part applies to radiators – for single-phase appliances, the rated-voltage is not
more than 250V; for other appliances, the rated-voltage is not more than 480V. The
radiators are used in household or similar sites. The radiators may be of portable type,
fixed type, stationary type etc.
This Part does not apply to.
-- the radiators installed in the structures of buildings;
-- the radiators specially designed for industrial purposes;
-- the radiators for the special environment where frequent use of corrosive or
explosive gases (such as dust, steam or gas) is intended.
Normative ReferencesThis chapter of QB/T 4096-2010 applies.
Terms and DefinitionsThis chapter of QB/T 4096-2010 applies, except the following contents.
3.101
liquid-filled radiator
A device which dissipates heat through its radiating fins and/or shell after the electric
heating elements heat the liquid in the inner cavity of radiating fins.
3.101.1
oil-filled radiator
A liquid-filled radiator which dissipates heat through its radiating fins and/or shell after
the electric heating elements heat the conduction oil in the inner cavity of radiating fins.
NOTE 101 Conduction oil is a category of special oil of good thermostability, which is used for
indirect transfer of heat.
3.101.2
water-filled radiator
A liquid-filled radiator which dissipates heat through its radiating fins and/or shell after
the electric heating elements heat the water in the inner cavity of radiating fins.
3.102
steady state
The heat balance state held after the radiator has achieved the maximum temperature
without changing.
4 Production Classification
This chapter of QB/T 4096-2010 is replaced by the following contents.
4.1 The classification in accordance with the control apparatus.
-- uncontrollable radiator;
-- power-controllable radiator;
-- temperature-controllable radiator.
4.2 The classification in accordance with the installation method.
-- portable radiator;
-- stationary radiator;
-- standing radiator.
4.3 The classification in accordance with the type of liquid filled in the inner cavity of
radiating fins.
-- electric heating oil-filled radiator;
-- electric heating water-filled radiator;
The precision of the instrument for measuring time is not lower than 1% of the time
measured.
6.5 Modification.
Keep the freezing chamber at (15 ± 2)°C; set the initial temperature of the laboratory
at (15 ± 2)°C; and keep the relative humidity not greater than 85%. Stop the air
exchange between the laboratory and the freezing chamber during the test.
NOTE 101 If, within 60 s, the temperature rise is not greater than 2 K, then it is deemed the
steady state is achieved.
6.6 Replacement.
The temperature-rise time of the radiators is measured during the test of 6.101.
Measure the time required for the radiators to acquire 90% of the surface maximum
temperature under the steady state conditions, as shown in Figure 101. For the
temperature at the maximum point of the radiators’ surface, the temperature acquired
in the first steady state shall be used as the reference; and the time of temperature-
rise is approximated to minute.
NOTE 101 The measuring methods and measuring points are same as that specified in 6.101.
6.101 Measurement of surface temperature
6.101.1 The radiators shall be placed in a test corner formed by two wallboards at
right angle to each other and one baseboard; and the test corner shall be made of
plywood, which is coated with matt black paint and of about 20 mm in thickness. The
specific layout is as follows.
-- for the radiators normally placed on the ground, place them as in normal use,
keeping the radiating side surface 300 mm from one wallboard and far from the
other wallboard. See Figure 102 for the radiating side surface of the radiators.
-- for the radiators normally fixed on the wall, fix them to one wallboard as in normal
use, keeping them as close to the other wallboard and baseboard as possible,
unless specified otherwise in the instructions for installation.
6.101.2 If the radiating surface of the radiators is planar or approximately planar, as
shown in Figure 103, divide the vertical center line of the radiating surface of the
radiators into four equal parts; and then arrange the thermocouples at the center points
of each equal division. Test the two planar radiating surfaces of the radiators;
meanwhile, use the temperature measuring and recording instrument to measure and
record the temperature curve (as shown in Figure 101) and temperature value from
the room temperature to the steady state of temperature. Determine the maximum
temperature of all measured surfaces when the steady state is established; use the
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of QB/T 4096.24-2024_English be delivered?Answer: Upon your order, we will start to translate QB/T 4096.24-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of QB/T 4096.24-2024_English with my colleagues?Answer: Yes. The purchased PDF of QB/T 4096.24-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version QB/T 4096.24-2024?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version QB/T 4096.24-2024 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|