HOME   Cart(12)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

JJG 693-2011 English PDF

US$459.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 693-2011: Verification regulation of Alarmer Detectors of Combustible Gas
Status: Valid

JJG 693: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 693-2011English459 Add to Cart 4 days [Need to translate] Verification regulation of Alarmer Detectors of Combustible Gas Valid JJG 693-2011
JJG 693-2004English759 Add to Cart 5 days [Need to translate] the Alarmer Detectors of Combustible Gas Obsolete JJG 693-2004
JJG 693-1990English679 Add to Cart 5 days [Need to translate] Verification Regulation of the Detector of Combustible Gases Obsolete JJG 693-1990

PDF similar to JJG 693-2011


Standard similar to JJG 693-2011

JJG 714   JJG 635   JJG 695   JJG 688   JJG 700   

Basic data

Standard ID JJG 693-2011 (JJG693-2011)
Description (Translated English) Verification regulation of Alarmer Detectors of Combustible Gas
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A61;C81
Classification of International Standard 13.320
Word Count Estimation 20,282
Date of Issue 2011-06-14
Date of Implementation 2011-12-14
Older Standard (superseded by this standard) JJG 693-2004; JJG 940-1998
Regulation (derived from) AQSIQ Announcement No. 90 of 2011
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to non-mine operating environment using the combustible gas detection alarm (including combustible gas detector, hereinafter referred to as "equipment") of the initial verification, testing and use of follow-up checks.

JJG 693-2011: Verification regulation of Alarmer Detectors of Combustible Gas

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification regulation of Alarmer Detectors of Combustible Gas State verification procedures People's Republic of China Combustible gas detection alarm Issued on. 2011-06-14 2011-12-14 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Combustible gas detection alarm verification procedures Replacing JJG 693-2004 JJG 940-1998 The regulations by the State Administration of Quality Supervision, Inspection and Quarantine on June 14, 2011, approved and since From December 14, 2011 into effect. Focal point. the National Technical Committee on Environment stoichiometry The main drafting units. China Institute of Metrology Jinan City, the metrological verification Shandong Province Institute of Metrology Jinan Changqing Computer Application Companies Participated in the drafting unit. Xi'an Institute of Measurement Henan Institute of Metrology Anyang City of Quality and Technical Supervision and Testing Center This procedure commissioned the National Technical Committee of the stoichiometric environment responsible for interpreting The main drafters of this procedure. Chen Yonghua (China Institute of Metrology) Wang Limin (Jinan City, the metrological verification) Gobo (Shandong Province Institute of Metrology) Yuezong Long (Changqing Computer Application Companies) Drafters participate. Zhuo (Xi'an Institute of Measurement) Kong Xiaoping (Henan Institute of Metrology) Li Yongjun (Anyang City of Quality and Technical Supervision and Testing Center)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2 Overview (1) 3 metering performance requirements (1) 4 General Requirements (1) 4.1 Appearance and structure (1) 4.2 marks, and logos (1) 4.3 energizing check (1) 4.4 alarm function and alarm operation value check (1) 4.5 Insulation Resistance (2) 5 control of measuring instruments (2) 5.1 verification Conditions (2) 5.2 Verification Project (3) 5.3 Verification Methods (3) 5.4 Verification Results Processing (5) 5.5 test cycle (5) Appendix A test recording format (6) Appendix B test certificates/test results in the notice page format (7) Appendix C Common combustible gas explosion limit (10)

Introduction

JJG 693-2011 "combustible gas detection alarm" is based JJF1002 "national verification procedures to prepare Rules ", JJF1001" common measurement terms and definitions ", JJF1059" Evaluation and Expression of Uncertainty in Measurement "Regulation Set of JJG 693-2004 "combustible gas detection alarm" and JJG 940-1998 "catalytic combustion of hydrogen gas detection Instrument "Two regulations revising. The revised procedures in place JJG 693-2004 "combustible gas detection alarm" and JJG 940-1998 "catalytic combustion of hydrogen detector" two procedures. And JJG 693-2004 and JJG 940-1998 phase Ratio, in addition to editorial changes outside the main technical changes are as follows. --- Expanding the subject of range. Comprising the measuring range. under 100% LEL (combustible gas explosion Limited concentration), low concentration (μmol/mol) and a high concentration (100% volume fraction); --- Remove the original statutes "instrument or use other structures may refer to this calibration procedure" content; --- Revised span drift indicators from the original range of ± 5% FS, adjusted to ± 3% FS (see Table 1); --- The original appearance of the statutes and a power check, modify the appearance and structure, sign and logo, energizing check And other three (see 4.1,4.2,4.3); --- Increased alarm operation value check, deletion of the original procedure error alarm test item (see 4.4); --- Specifically defined the type of gas standard material. k gas standard material containing factor from the original 3 = Modify k = 2 (see 5.1.2.1); --- Removed the original procedure in Appendix B "standard material traceability requirements." The standard gas dilution device included positive Text (see 5.1.2.1); --- Indication error test method increases the traffic control requirements, delete the original procedure in Appendix A "traffic Requirements "(see 5.1.2.2); --- Modify the test results and the test results of notice-page format. The modified-page format so that users clearly We know the specific targets of the seized equipment at different points. The previous versions of the release JJG 693-2004 case. --- JJG 693-2004; --- JJG 693-1990. JJG 940-1998 of previously issued as follows. --- JJG 940-1998. Combustible gas detection alarm verification procedures

1 Scope

The order applies to non-mine operating environment for use in combustible gas detection alarm (including the detection of combustible gases Instrument, hereinafter referred to as "instrument") of the initial verification, use and subsequent verification check.

2 Overview

The main instrument detection principle catalytic combustion type, infrared absorption, thermal conductivity type. Sampling methods are diffused And inhaled. Instruments mainly by the detection element, an amplification circuit, alarm systems, monitors and other components for monitoring the environment The concentration of combustible gases.

3 metering performance requirements

Measurement performance requirements are shown in Table 1. Table 1 metrological requirements Project Requirements Indication error ± 5% FS Repeatability ≤2% Response time Diffusion ≤60s Inhaled ≤30s drift Zero drift ± 3% FS Span drift ± 2% FS Note. "FS" indicates that the instrument of full scale, the same below.

4 General technical requirements

4.1 Appearance and structure 4.1.1 The instrument shall not affect the appearance of their normal work injury. Surface of the new instrument should be made smooth, paint Color uniform coating, no rust flaking phenomenon. 4.1.2 Instrument reliable connection, each knob or button shall be able to operate and control. 4.2 marks, and logos Made instrument name, model number, manufacturer name, date of manufacture, serial number, serial number and proof mark and domestic equipment Measuring instruments manufacturing license logo and number, etc. should be complete and clear. 4.3 energizing check After the instrument is powered, the instrument should be able to work properly, the display portion should be clear and complete. 4.4 alarm function and alarm operation value check

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 693-2011_English be delivered?

Answer: Upon your order, we will start to translate JJG 693-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 693-2011_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 693-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 693-2011?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 693-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.