JJG 270-2008: Verification regulation of sphygmomanometer
Status: Valid

JJG 270: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 270-2008English269 Add to Cart 3 days [Need to translate] Verification regulation of sphygmomanometer Valid JJG 270-2008
JJG 270-1995English399 Add to Cart 3 days [Need to translate] Verification Regulation of the Desk Sphygmomanometer Obsolete JJG 270-1995
JJG 270-1988EnglishRFQ ASK 3 days [Need to translate] Verification Regulation of the Desk Sphygmomanometer Obsolete JJG 270-1988

PDF similar to JJG 270-2008


Standard similar to JJG 270-2008

JJG 162   GB/T 36126   GB/T 1885   JJG 126   JJG 276   JJG 264   

Basic data

Standard ID JJG 270-2008 (JJG270-2008)
Description (Translated English) Verification regulation of sphygmomanometer
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A53
Classification of International Standard 17.100
Word Count Estimation 11,133
Date of Issue 2008-03-25
Date of Implementation 2008-09-25
Older Standard (superseded by this standard) JJG 270-1995
Regulation (derived from) ?AQSIQ Announcement 2008 No.35
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to all kinds of instrument calibration initial verification, subsequent test and use the test.

JJG 270-2008: Verification regulation of sphygmomanometer

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification regulation of sphygmomanometer State verification procedures People's Republic of China Sphygmomanometer and blood pressure table Posted 2008-03-25 2008-09-25 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Sphygmomanometer and blood pressure meter testing procedures Replacing JJG 270-1995 The regulations by the State Administration of Quality Supervision, Inspection and Quarantine, 2008 March 25 ratification and From September 25, 2008 into effect. Focal point. the National Technical Committee of pressure measurement Main drafting unit. Shanghai Institute of Measurement and Testing Participated in the drafting unit. Beijing Huaxin Tech Co., Ltd. YIMT test The measurement procedure commissioned the National Technical Committee is responsible for interpreting pressure The main drafters of this procedure. Tu Li Meng (Shanghai Institute of Measurement and Testing) Huan Lun (Shanghai Institute of Measurement and Testing) Drafters participate. Gong Li Ying (Shanghai Institute of Measurement and Testing) Sun Tian Yuan (Beijing Huaxin Tech Co., Ltd.) Chang Xuan (YIMT test)

table of Contents

1 Scope (1) 2 Overview (1) 3 metering performance requirements (1) 3.1 Zero Error (1) Sensitivity 3.2 sphygmomanometer (1) Tightness 3.3 (1) 3.4 indication error (1) 3.5 blood pressure table pointer deflection stability (1) 4 General Requirements (1) 4.1 Appearance (1) 5 control of measuring instruments (2) 5.1 verification Conditions (2) 5.2 Verification Project (2) 5.3 Verification Methods (3) 5.4 test results processing (4) 5.5 test cycle (4) Appendix A sphygmomanometer, blood pressure meter calibration record format (5) Appendix B sphygmomanometer, blood pressure meter calibration certificate, test results in the notice page format (6) Sphygmomanometer and blood pressure meter testing procedures

1 Scope

The order applies to (desktop and vertical) mercury sphygmomanometer (hereinafter referred to as sphygmomanometer) and elastic blood pressure table (to Hereinafter referred to as blood pressure table) initial verification, subsequent verification and in-service inspection.

2 Overview

Sphygmomanometer blood pressure table and the hospital or home blood pressure was observed using the indirect method of measuring instruments. Sphygmomanometer working principle is based on the principle of hydrostatic equilibrium, by the communication unit of the mercury reservoir bottle and the indication tube communicating, when After the mercury storage bottle mercury surface pressure, forcing indication within the mercury rises indicating that the pressure value. Blood pressure table is based on Hooke's law is made, the working principle is tested under pressure, forcing the elastic sensing element (Elastic film cartridge) with a corresponding elastic deformation --- displacement, by means of a connecting rod, shaft drive through a gear transmission mechanism And is amplified by the fixed gear shaft pointer gradually measured pressure value indicated on the index plate.

3 metering performance requirements

3.1 zero error 3.1.1 mercury sphygmomanometer reservoir bottle and the atmosphere, mercury readings should be at the top surface and the zero scale line tangent bits Home, a tolerance of. -0.2kPa ~ 0.5kPa (-1.5mmHg ~ 3.75mmHg). After the elastic sensing element 3.1.2 blood pressure meter lumen with the atmosphere, the pointer should be in the zero mark. 3.2 sphygmomanometer sensitivity When the mercury in the rapid decline in the sudden pause, the volatility of not less than 0.3kPa (2.25mmHg). 3.3 tightness 3.3.1 rubber ball valve knob on tightening should not leak, unscrew should not fall off; return valve should stop for gas use. 3.3.2 sphygmomanometer, blood pressure table in 1min pressure drop. the first test should not exceed 0.5kPa (3.75mmHg), Subsequent in-service inspection and verification should not exceed 0.8kPa (6mmHg); mercury sphygmomanometer bottle storage not leak mercury, mercury Column may not have turned bubble phenomenon. 3.4 Indication error Indication sphygmomanometer, blood pressure table are the maximum permissible error. ± 0.5kPa (± 3.75mmHg). 3.5 blood pressure table pointer deflection stability Blood pressure table pointer deflection should be stable and should not be beating and stagnation.

4 General technical requirements

4.1 Appearance 4.1.1 sphygmomanometer, blood pressure meter housing should be sturdy, and protects the internal components from damage and not be defiled. 4.1.2 newly manufactured sphygmomanometer, blood pressure meter housing coating gloss coating should be uniform, no obvious stripping phenomenon.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 270-2008_English be delivered?

Answer: Upon your order, we will start to translate JJG 270-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 270-2008_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 270-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 270-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 270-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.