HOME   Cart(12)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

JJG 246-2005 English PDF

US$729.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 246-2005: Verification Regulation of Standard Lamp of Luminous Intensity
Status: Valid

JJG 246: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 246-2005English729 Add to Cart 5 days [Need to translate] Verification Regulation of Standard Lamp of Luminous Intensity Valid JJG 246-2005
JJG 246-1991English799 Add to Cart 5 days [Need to translate] Verification Regulation of Standard Lamp of Luminous Intensity Obsolete JJG 246-1991
JJG 246-1981EnglishRFQ ASK 3 days [Need to translate] (Chinese Industry Standard) Obsolete JJG 246-1981

PDF similar to JJG 246-2005


Standard similar to JJG 246-2005

JJG 178   JJG 245   JJG 810   JJG 452   JJG 211   JJG 247   

Basic data

Standard ID JJG 246-2005 (JJG246-2005)
Description (Translated English) Verification Regulation of Standard Lamp of Luminous Intensity
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A60
Classification of International Standard 17.180
Word Count Estimation 28,246
Date of Issue 2005-03-03
Date of Implementation 2005-09-03
Older Standard (superseded by this standard) JJG 246-1991; JJG 732-1991
Issuing agency(ies) State Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to luminous intensity standard lamp (referred to standard lamps) for initial verification, testing and use of follow-up inspection. Standard lamp shape identification requirements relating to metrological performance can be implemented by reference.

JJG 246-2005: Verification Regulation of Standard Lamp of Luminous Intensity

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Standard Lamp of Luminous Intensity National Metrology Verification Regulations of the People's Republic Luminous intensity standard lamp Released on.2005-03-03 2005-09-03 implementation The General Administration of Quality Supervision, Inspection and Quarantine issued Replace JJG 246-1991 JJG 732-1991 This regulation was approved by the General Administration of Quality Supervision, Inspection and Quarantine on March 3,.2005, and It will take effect on September 3,.2005. Focal Point. National Optical Metrology Technical Committee Drafted by. China Institute of Metrology This procedure entrusts the National Optical Metrology Technical Committee to explain Drafters of this procedure. Ma Yan (China Institute of Metrology) Gao Zhizhong (China Institute of Metrology)

table of Contents

1 Scope (1) 2 Citations (1) 3 Overview (1) 4 Metrology performance requirements (1) 4.1 Luminous intensity standard lamp stability (1) 4.2 Luminous intensity standard lamp angle characteristics (1) 4.3 Annual rate of change of standard lamp luminous intensity value (1) 4.4 Uncertainty of the expansion of the standard lamp luminous intensity value (2) 5 General technical requirements (2) 5.1 Appearance (2) 5.2 Identification (2) 6 measuring instrument control (2) 6.1 Verification conditions (2) 6.2 Verification project (3) 6.3 Verification method (3) 6.4 Processing of verification results (8) 6.5 verification period (8) Appendix A Photoelectric parameters of domestic luminous intensity standard lamps (9) Appendix B Determination of horizontal and vertical angle characteristics (10) Appendix C Calculation Method of Measurement System Unstable Correction Coefficient (11) Appendix D Verification of the non-linearity of the photometer (12) Appendix E Calculation Method of Mismatch Correction Coefficient (13) Appendix F Example of Uncertainty Evaluation (14) Appendix G Verification of the original record of the standard record of luminous intensity standard lamp by equidistance method (17) Appendix H Luminous Intensity Standard Lamp Verification Certificate and Verification Result Notice (inside page) format (23) Luminous intensity standard lamp verification procedure

1 Scope

This procedure is applicable to the first verification, subsequent verification and in-use inspection of luminous intensity standard lamps (referred to as standard lamps). Test. The requirements for metering performance in standard lamp qualification can be referred to.

2 Citations

JJG 213-2003 "Distribution (color) temperature standard lamp" When using this procedure, care should be taken to use the current valid version of the above cited documents.

3 Overview

Luminous intensity standard lamps are measuring instruments that maintain and transmit a unit of luminous intensity. It is made to specific requirements An incandescent lamp with stable illuminating characteristics, the illuminants are arranged in a plane, the shape of the bulb and the additional aperture are sought to avoid or Reduce stray light. Such a lamp has a uniform light distribution in the measurement direction and has excellent reproducibility of magnitude.

4 Metrological performance requirements

4.1 Luminous intensity standard lamp stability Luminous intensity standard lamps must be aged according to relevant regulations before leaving the factory. The stability of the lamp after aging should be achieved. When the test current (see Appendix A) is ignited for 4h, the lamp terminal voltage change of the vacuum lamp should be less than 0.15%, and the lamp end of the gas lamp The voltage change should be less than 0.25%. 4.2 Luminous intensity standard lamp angle characteristics Luminous intensity standard lamps should have good horizontal and vertical angle characteristics, and the lamp should be rotated ±1.5° in the horizontal direction. When the luminous intensity changes by no more than 0.6%. When the bulb is rotated ±1.0° in the vertical direction, the luminous intensity does not change more than 0.6%. 4.3 Annual rate of change of standard lamp luminous intensity value The luminous intensity standard lamp for the first inspection is not rated. Year after the re-examination, the year according to the luminous intensity of the lamp The rate of change and the level of the standard lamp used for calibration of this lamp are rated as specified in Table 1. Table 1 Annual change rate of luminous intensity of lamps at each level The annual change rate of the luminous intensity of the standard lamp level to be tested should be less than Sub Benchmark Work Benchmark 0.5% Work benchmark level 0.7% Level 1 and Level 1.2% The annual rate of change of the luminous intensity of a standard lamp is calculated by the following formula.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 246-2005_English be delivered?

Answer: Upon your order, we will start to translate JJG 246-2005_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 246-2005_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 246-2005_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 246-2005?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 246-2005 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.