JJG 155-2016: Routine Capillary Viscometers
Status: Valid

JJG 155: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 155-2016English419 Add to Cart 4 days [Need to translate] Routine Capillary Viscometers Valid JJG 155-2016
JJG 155-1991English759 Add to Cart 4 days [Need to translate] Verification regulation of routine capillary viscometer Obsolete JJG 155-1991
JJG 155-1979EnglishRFQ ASK 3 days [Need to translate] Verification Regulation of Routine Capillary Viscometer Obsolete JJG 155-1979

PDF similar to JJG 155-2016


Standard similar to JJG 155-2016

GB/T 36126   JJG 150   GB/T 1885   JJG 159   JJG 162   JJG 147   

Basic data

Standard ID JJG 155-2016 (JJG155-2016)
Description (Translated English) Routine Capillary Viscometers
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A53
Classification of International Standard 17.060
Word Count Estimation 18,136
Date of Issue 2016-06-27
Date of Implementation 2016-12-27
Older Standard (superseded by this standard) JJG 155-1991
Quoted Standard JJG 2016
Regulation (derived from) Notice of the General Administration of Quality Supervision, Inspection and Quarantine of the People Republic of China 2016 No.16
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to the Uberto type, flat open Wei Qi type, Fenske type and counter-current type of gravity (also known as free flow) Working capillary viscosity (Hereinafter referred to as viscometer) of the first test, follow-up test and use of the inspection.

JJG 155-2016: Routine Capillary Viscometers

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Routine Capillary Viscometers National Metrological Verification Regulation of the People's Republic of China Working capillary viscometer 2016-06-27 released 2016-12-27 implementation State Administration of Quality Supervision, Inspection and Quarantine issued Working capillary viscometer Verification procedures Replacing JJG 155-1991 Responsible unit. National Physical and Chemical Metrology Technical Committee Drafting unit. China Institute of Metrology Jiangsu Institute of Metrology This procedure entrusts the National Physical Chemistry Metrology Technical Committee to explain The main drafters of this procedure. Zhang zhengdong (China Institute of Metrology) Song Jian (Jiangsu Institute of Metrology) Participate in the drafters. Huang Pu (China Institute of Metrology)

table of Contents

Introduction (II) 1 Scope (1) 2 References (1) 3 Overview (1) 4 Measurement performance requirements (1) 5 General technical requirements (3) 5.1 Appearance requirements (3) 5.2 Identification (3) 6 Metering device control (3) 6.1 Test conditions (3) 6.2 Test items and test methods (4) 6.3 Processing of Verification Results (7) 6.4 Verification cycle (7) Appendix A Viscosity Standard Selection Reference (8) Appendix B Verification Record Format (10) Appendix C Certificate of Verification and Verification Result Form (11)

Introduction

This procedure to JJF1002-2010 "national measurement procedures for the preparation of rules", JJF1001-2011 "General Metrological terms and definitions ", JJF1059.1-2012" Measurement uncertainty assessment and representation "as a basic specification Revised. Compared with JJG 155-1991, the main contents of this revision are as follows. --- increase "Introduction"; --- increase the measurement performance indicators of viscometer constant stability indicators, see Table 2; --- delete the original program "Table 2 standard solution" related content; - to remove the limits of the original test area for the verification temperature range; --- increase the stability of the constant calculation method, see "6.2.2.5 constant stability"; --- delete the original program example; --- delete the original procedure "Appendix 1 standard viscosity of the liquid value of the method"; --- modify the original procedure "Appendix 2 at 20 ℃ test capillary viscometer standard viscosity liquid grade" as "Appendix A viscosity standard selection reference "; --- Modify the original record and certificate format, see Appendix B and Appendix C. The previous version of this procedure is released as follows. --- JJG 155-1991. Verification of working capillary viscometer

1 Scope

This procedure applies to Uzbekot type (referred to as Wu's), flat open Wei Qi type (referred to as Ping's), Finske type (referred to as (Hereinafter referred to as "free flow") working capillary viscometer (hereinafter referred to as viscometer) The first test, follow-up test and the use of inspection.

2 reference file

JJG 2016 Viscometer Measuring Instrument For dated references, only the dated edition applies to this rule; references that are not dated , The latest version (including all amendments) applies to this procedure.

3 Overview

Viscometer is mainly used for liquid sample kinematic viscosity measurement. Measured at a certain temperature using a constant viscosity known The volume of liquid flowing through the capillary is calculated by the formula (1) to calculate the kinematic viscosity of the liquid. ν = Ct (1) Where. ν --- the kinematic viscosity of the liquid, mm2 · s-1; C - viscometer constant, mm2 · s-2; t --- a certain volume of liquid flow through the capillary time, s.

4 Measurement performance requirements

The first test of the viscometer, the subsequent verification and the use of inspection should meet the measurement performance requirements of Table 1 and Table 2. Table 1 Time Repetition and Constant Reproducibility Indicators Viscometer Uchiel, flat, Fenbu countercurrent Constant standard value ≤ 1mm2 · s-2 > 1mm2 · s-2 Time repeatability * 0.2% 0.3% 0.3% Constant reproducibility ** 0.3% 0.4% 0.4% * For countercurrent viscometer, with the same liquid twice the liquid measured value of the calculation. ** For countercurrent viscometers, calculate the two constant values measured with different liquids.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 155-2016_English be delivered?

Answer: Upon your order, we will start to translate JJG 155-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 155-2016_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 155-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 155-2016?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 155-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.