US$459.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1527-2015: Calibration specification for polymerase chain reaction analyzers Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1527-2015 | English | 459 |
Add to Cart
|
4 days [Need to translate]
|
Calibration specification for polymerase chain reaction analyzers
| Valid |
JJF 1527-2015
|
PDF similar to JJF 1527-2015
Basic data Standard ID | JJF 1527-2015 (JJF1527-2015) | Description (Translated English) | Calibration specification for polymerase chain reaction analyzers | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A61 | Classification of International Standard | 17.020 | Word Count Estimation | 20,298 | Date of Issue | 2015-06-15 | Date of Implementation | 2015-09-15 | Quoted Standard | GB/T 6682-2008; YY/T 1173-2010 | Regulation (derived from) | AQSIQ Announcement 2015 No.72 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This Standard applies to heating module polymerase chain reaction (PCR) measurement of performance analyzer calibration for other types of PCR, may refer to this standard. |
JJF 1527-2015: Calibration specification for polymerase chain reaction analyzers---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration specification for polymerase chain reaction analyzers
People's Republic of China National Metrology Technical Specifications
Polymerase chain reaction analyzer calibration specification
Issued on. 2015-06-15
2015-09-15 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Polymerase chain reaction analyzer calibration specification
zers
NFP. National Technical Committee biometric
The main drafting units. China Institute of Metrology
Participated in the drafting unit. Shanghai Institute of Measurement and Testing
Guangdong Provincial Institute of Metrology
Tianjin Institute of Supervision and Testing Weighing
This specification entrusted to the National Technical Committee is responsible for interpreting biometric
The main drafters of this specification.
GAO Yun Hua (China Institute of Metrology)
Drafters participate.
Zhang Liping (Shanghai Institute of Measurement and Testing)
Yin Qiang (Guangdong Institute of Metrology)
Tian Yun (Tianjin Supervision and Testing Institute of Metrology)
Paul Zhijuan (Guangdong Institute of Metrology)
Wu Jianying (Shanghai Institute of Measurement and Testing)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2. References (1)
3 Terms (1)
3.1 Polymerase chain reaction (1)
3.2 Polymerase chain reaction analyzer (1)
4 Overview (1)
5 Metrological characteristics (1)
Calibration Condition 6 (2)
6.1 Calibration equipment and reference material (2)
7 calibration items and calibration methods (2)
7.1 Calibration Condition (2)
7.2 Temperature indication error, temperature uniformity calibration (2)
7.3 l cooling rate calibration (4)
7.4 Quantitative PCR instrument indication error sample, sample linear calibration (5)
8 calibration results expression (6)
9 Recalibration interval (6)
Appendix A standard preparation and the preparation of material (7)
Appendix B PCR reaction system preparation (9)
Appendix C shows the temperature calibration error of Uncertainty evaluation model (10)
Appendix D shows a sample error of Uncertainty evaluation model (12)
Appendix E calibration reference the original record format (14)
F calibration certificate (within the page) reference format (15) Appendix
Introduction
The preparation of the specification based on the polymerase chain reaction analyzer main technical parameters of experimental tests, reference is made JJF 1030-
2010 "bath calibration specification", SN/T 2102.1-2008/ISO 22174.2005 "Foodborne pathogens PCR
Detection Technical specifications - Part 1. General requirements and definitions ", SN/T 2102.2-2008/ISO 20836.2005
"Foodborne pathogens PCR detection technology specification Part 2. PCR performance test requirements", YY/T 1173-
2010 "polymerase chain reaction analyzer" and other documents.
This specification is the first release.
Polymerase chain reaction analyzer calibration specification
1 Scope
This instruction applies to polymerase chain reaction module heating (PCR) analyzer calibration measurement of performance, other
Types of PCR, can refer to these specifications.
2. References
This specification refers to the following documents.
GB/T 6682-2008 national standard analytical laboratory use
YY/T 1173-2010 polymerase chain reaction analyzer
For dated references, only the dated edition applies to this specification; undated reference documents
Member, the latest edition (including any amendments) applies to this specification.
3 Terms
3.1 Polymerase chain reaction polymerasechainreaction, PCR [YY/T 1173-20103.1]
Kind of specific DNA or RNA fragments in vitro method of rapid amplification by denaturation - Annealing - extension
Stretched three basic reaction steps constitute.
3.2 Polymerase chain reaction analyzer polymerasechainreactionanalyzer [YY/T 1173-20103.2]
Based on PCR (polymerase chain reaction) technology principle, the analog of DNA or RNA replication, the template,
Under a primer, polymerase and other conditions of existence, specific amplification of known sequences, its detection and analysis of equipment.
4 Overview
Polymerase chain reaction analyzer is based on replication PCR technology principle, simulate DNA or RNA, in the mold
The lower plate, primers, polymerase and other conditions of existence, known sequence specific amplification, detection and analysis of its instruments provided
Equipment, including qualitative and quantitative PCR instrument PCR instrument categories. Qualitative PCR usually consists of a sample stage, thermal cycling components,
Control and power components with parts and other components. Quantitative PCR instrument consists of a sample stage, thermal cycling part, the control unit
Constituent elements, optical detection means, power components, computer and application software components.
5 Metrological characteristics
Metrological characteristics are shown in Table 1.
Table 1 polymerase chain reaction analyzer metrological characteristics
Project stereotypes PCR quantitative PCR instrument
Temperature indication error
Temperature uniformity
The average heating rate
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1527-2015_English be delivered?Answer: Upon your order, we will start to translate JJF 1527-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1527-2015_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1527-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|