US$439.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1407-2013: Calibration Specification for Thermometers of WBGT-index Meters Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1407-2013 | English | 439 |
Add to Cart
|
4 days [Need to translate]
|
Calibration Specification for Thermometers of WBGT-index Meters
| Valid |
JJF 1407-2013
|
PDF similar to JJF 1407-2013
Basic data Standard ID | JJF 1407-2013 (JJF1407-2013) | Description (Translated English) | Calibration Specification for Thermometers of WBGT-index Meters | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A54 | Classification of International Standard | 17.200 | Word Count Estimation | 19,183 | Quoted Standard | JJG 205-2005; GB/T 4200-2008; GB/T 17244-1998 | Regulation (derived from) | ?AQSIQ Announcement 2013 No. 74; | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to WBGT index meter thermometer calibration. WBGT index meter including natural wet bulb thermometer, black bulb thermometer and a dry bulb thermometer. Natural wet bulb thermometer measuring range: 5��C ~ 40��C, black bulb thermometer |
JJF 1407-2013: Calibration Specification for Thermometers of WBGT-index Meters---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Thermometers of WBGT-index Meters
People's Republic of China National Metrology Technical Specifications
WBGT Index instrument thermometer calibration specification
Issued on. 2013-05-13
2013-08-13 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
WBGT Index instrument thermometer calibration specification
Focal point. the National Technical Committee of temperature measurement
The main drafting units. Shandong Institute of Metrology
Zhejiang Institute of Metrology
Participated in the drafting unit. Xinjiang Institute of Measurement and Testing
Beijing Institute of Metrology detection
This specification commissioned the National Technical Committee is responsible for interpretation of temperature measurement
The main drafters of this specification.
Sun Shulan (Shandong Province Institute of Metrology)
Zhang Jiong (Shandong Province Institute of Metrology)
Zhanghua Wen (Shandong Province Institute of Metrology)
Shen Zhong only (Zhejiang Institute of Metrology)
Drafters participate.
Ma Xiaochun (Xinjiang Institute of Measurement and Testing)
With meritorious (Xinjiang Institute of Measurement and Testing)
Zhang Yi farmers (Beijing Institute of Metrology detection)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2. References (1)
3 Terms and definitions (1)
3.1 WBGT index (1)
3.2 WBGT Index instrument thermometer (1)
3.3 thermal load (1)
3.4 Effective area (1)
4 Overview (1)
5 Metrological characteristics (2)
Calibration Condition 6 (2)
6.1 environmental conditions (2)
6.2 Standard device and ancillary equipment (3)
7 calibration items and calibration methods (3)
7.1 calibration items (3)
7.2 Calibration method (3)
8 calibration results expression (5)
9 Recalibration interval (5)
Appendix A WBGT Index instrument thermometer calibration original record format (6)
Appendix B Calibration Certificate page format (7)
Appendix C measurement (indication error) Uncertainty evaluation of a sample (8)
Appendix D measurements (indication error) Uncertainty Evaluation of Example Two (11)
Introduction
This specification based JJF 1071-2010 "National Calibration Specifications writing rules" establishment, where measurement uncertainty
Evaluation of in accordance JJF 1059.1-2012 "Evaluation and Expression of Uncertainty in Measurement" in.
The specification for the first time to develop.
WBGT Index instrument thermometer calibration specification
1 Scope
This instruction applies to WBGT Index instrument thermometer calibration. WBGT Index instrument, including natural wet bulb thermometer
Meter, the black bulb thermometer and dry bulb thermometer. Natural wet bulb thermometer measuring range. 5 ℃ ~ 40 ℃; black-bulb temperature
Meter measuring range. 20 ℃ ~ 120 ℃; dry bulb thermometer measuring range. 10 ℃ ~ 60 ℃.
2. References
This specification refers to the following documents.
JJG205-2005 mechanical hygrometer
GB/T 4200-2008 hot job classification
GB/T 17244-1998 thermal environment based on WBGT index (wet bulb globe temperature) of the thermal load workers
Evaluation charge
For dated references, only the dated edition applies to this specification; undated reference documents
Member, the latest edition (including any amendments) applies to this specification.
3 Terms and definitions
3.1 WBGT index WBGT-index
Also known as the wet bulb, black bulb temperature, is a comprehensive evaluation of the basic parameters of human exposure to the operating environment of the thermal load, single
Bit ℃. [GB/T 4200-2008,3.4]
3.2 WBGT Index instrument thermometer thermometerofWBGT-indexmeter
WBGT Index instrument measuring natural wet bulb temperature, globe temperature, dry bulb temperature of the thermometer.
3.3 heat load heatstress
The extent of the human body heat when operating in a hot environment to WBGT index, said heat depends on manual labor
And the amount of heat exchange between the environment and human characteristics. [GB/T 17244-1998,2.2]
3.4 effective area effectivearea
Meet the appropriate space temperature fluctuation and uniformity required in an incubator, or product specification prescribed area.
4 Overview
WBGT index is a basic parameter of human exposure to environmental heat load. WBGT Index instrument were measured
Natural wet bulb temperature, globe temperature, dry bulb temperature and the three parameters, then get WBGT index calculated by the formula.
WBGT Index instrument usually consists of a temperature sensor and instrument host of two parts, natural wet bulb temperature, black ball temperature
And dry-bulb temperature of the three sensors mounted on the same bracket, there are two connections and a direct connection by measuring cable
Forms. FIG. 1 (a) and 1 (b) below.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1407-2013_English be delivered?Answer: Upon your order, we will start to translate JJF 1407-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1407-2013_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1407-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|