HOME   Cart(1)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

JJF 1261.2-2017 English PDF

JJF 1261.2: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1261.2-2017EnglishRFQ ASK 5 days [Need to translate] Rules of Metrology Testing for Energy Efficiency of Room Air Conditioners Obsolete JJF 1261.2-2017
JJF 1261.2-2010EnglishRFQ ASK 6 days [Need to translate] Rules of metrology testing for energy efficiency label of room air conditioners Obsolete JJF 1261.2-2010

PDF similar to JJF 1261.2-2017


Standard similar to JJF 1261.2-2017

JJF 1016   JJF 1059.1   JJF 1071   JJF 1261.10   JJF 1261.6   JJF 1261.5   

Basic data

Standard ID JJF 1261.2-2017 (JJF1261.2-2017)
Description (Translated English) Rules of Metrology Testing for Energy Efficiency of Room Air Conditioners
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A50
Classification of International Standard 17.020
Word Count Estimation 34,354
Date of Issue 2017-09-26
Date of Implementation 2018-03-26
Older Standard (superseded by this standard) JJF 1261.2-2010
Quoted Standard JJF 1261.1-2017; GB/T 2829-2002; GB/T 7725-2004; GB 12021.3-2010; GB 17790-2008
Regulation (derived from) General Administration of State Quality Inspection Announcement 2017 No. 78
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard specifies the measurement requirements for energy efficiency of air conditioners using air-cooled condensers, fully-enclosed motor-compressors, cooling capacity of 14 000 W and below, and climate type T1, metrological testing procedures, metrology and testing methods, and metrological testing. Results assessment criteria and test reports. This standard is applicable to the measurement and supervision of energy efficiency measurement of air conditioners. Commissioned inspections can refer to this standard. Units that produce and sell air conditioners may also use this standard for testing. The air-conditioner energy efficiency measurement and detection method specified in this standard is the air-enthalpy method. This standard does not apply to mobile air conditioners, speed controllable air conditioners and multi-connected air conditioning units. The air conditioner to be tested shall be the product that the producer has passed the inspection of himself or the goods imported or sold by the seller.

JJF 1261.2-2017: Rules of Metrology Testing for Energy Efficiency of Room Air Conditioners

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Rules of Metrology Testing for Energy Efficiency of Room Air Conditioners People's Republic of China National Metrology Technical Specifications Room air conditioner energy efficiency Metering detection rules Published on.2017-09-26 2018-03-26 implementation The State Administration of Quality Supervision, Inspection and Quarantine issued Room air conditioner energy efficiency Metering detection rules Replacing JJF 1261.2-2010 Key units. National Legal Measurement Management and Measurement Technology Committee Energy Efficiency Marking Measurement Inspection Sub-Technical Committee Drafted by. China Academy of Metrology Participated in drafting. Shandong Institute of Metrology Zhejiang Institute of Metrology Zhuhai Gree Electric Co., Ltd. Guangdong Zhigao Air Conditioning Co., Ltd. This Code entrusts the National Legal System Measurement Management Technical Committee to measure the efficiency of energy efficiency labeling Technical Committee is responsible for explaining The main drafters of this specification. Xu Dinghua (China Institute of Metrology) Hang Chenzhe (China Institute of Metrology) Haiyun Zhang (China Institute of Metrology) Participating drafters. Lu Huizheng (Shandong Institute of Metrology) Yu Shifan (Zhejiang Institute of Metrology) Chen Jin (Zhuhai Gree Electric Appliance Co., Ltd.) You Shunyi (Guangdong Chigo Air Conditioning Co., Ltd.)

table of Contents

Introduction (III) 1 Scope (1) 2 References (1) 3 Terms and units of measure (1) 4 Overview (2) 5 Metrological requirements (2) 5.1 Energy Efficiency Labelling (2) 5.2 Energy Index (Energy Consumption) (2) 5.3 Energy efficiency rating (3) 6 Testing conditions (3) 6.1 Environmental Conditions (3) 6.2 Measuring Equipment (3) 6.3 Measurement uncertainty (4) 7 Testing Items and Methods (4) 7.1 Sampling Principles and Methods (4) 7.2 Sample Testing (4) 7.3 Original records (6) 7.4 Data Processing (6) 8 Test Results (6) 8.1 Eligibility Criteria for Energy Efficiency Index (Energy Consumption) Measurement Test Results (6) 8.2 Test results assessment criteria (7) 8.3 Test Report (8) Appendix A Room Air Conditioner Cooling Capacity Air Enthalpy Method Measurement Method (9) Appendix B Air Enthalpy Method Room Air Conditioner Energy Efficiency Measurement Uncertainty Evaluation Example (14) Appendix C Room Air Conditioner Energy Efficiency Measurement Inspection Sample Sheet (Format) (21) Appendix D Room Air Conditioner Energy Efficiency Metering Original Record (Format) (22) Appendix E Room Air Conditioner Energy Efficiency Measurement Test Report (Format) (25)

Introduction

To regulate the energy efficiency of room air conditioners (hereinafter referred to as air conditioners) that implement energy efficiency label management The measurement and inspection work is based on the requirements of JJF 1261.1-2017 Energy Efficiency Measurement and Detection Rules for Energy Products. Finalize the specification. This specification replaces JJF 1261.2-2010, compared with JJF 1261.2-2010, except for editorial modifications, the main To change as follows. --- The name of the specification was changed from "Room Air Conditioner Energy Efficiency Labelling Metrology Test Rule" to "Room Air Conditioning" Energy efficiency metering detection rules"; --- Add "Introduction", replace "cited documents" with "reference documents" and replace "terms and definitions" with " Languages and units of measure"; --- "5.1 energy efficiency labeling" adds "energy efficiency information code" and "energy efficiency" 'leader' information" And other requirements; --- The original record format and test report format were revised accordingly (Appendix D, Appendix E). The previous versions of this specification were issued as follows. ---JJF 1261.2-2010. Room air conditioner energy efficiency Metering detection rules

1 Scope

This specification specifies the use of air-cooled condensers, fully enclosed motor-compressors, and cooling capacity of 14,000 W And below, measurement requirements for the energy efficiency of air conditioners with climate type T1, metrological testing procedures, and metrological testing Laws, measurement results, assessment criteria and test reports. This specification applies to energy efficiency measurement and supervision of air conditioners. Commissioned inspections can be performed with reference to this specification. Production and Units selling air conditioners can also be tested with reference to this specification. The air-conditioner energy efficiency measurement and detection method specified in this specification is the air-enthalpy method. This specification does not apply to mobile air conditioners, speed-controlled air conditioners and multi-connected air-conditioning units. The air conditioner to be tested shall be the product that the producer has passed the inspection of himself or the goods imported or sold by the seller.

2 references

This specification refers to the following documents. JJF 1261.1-2017 Energy Product Energy Efficiency Measurement Inspection Rules GB/T 2829-2002 Periodic Inspection Count Sampling Procedures and Tables (Applicable to Inspection of Process Stability) GB/T 7725-2004 room air conditioner GB 12021.3-2010 Room air conditioner energy efficiency limit and energy efficiency rating GB 17790-2008 Specification for installation of household and similar air conditioners For dated references, only dated editions apply to this specification; all undated references The latest version (including all amendments) applies to this specification.

3 Terms and units of measure

The following terms and units of measurement apply to this specification. 3.1 Total cooling capacity When the air conditioner performs cooling operation under rated conditions and specified conditions, the unit time from the confined space, the room or The total amount of heat removed in the area, in units of W. 3.2 Input power inputpower The total power input when the air conditioner is operating under rated conditions and under specified conditions, in units of W. 3.3 Energy Efficiency Ratio [EER] energyefficiencyratio[EER] The ratio of the cooling capacity to the effective input power when the air conditioner performs cooling operation under rated conditions and specified conditions. The value is in W/W. 3.4 Energy efficiency limit value minimumimableablevalueofenergyefficiency The minimum allowable value of the energy efficiency ratio under rated operating conditions when the air conditioner is in cooling operation. 3.5 Air-enthalpy test method