HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (1 Dec 2024)

GB/T 6730.84-2023 Related PDF English

GB/T 6730.84-2023 (GB/T6730.84-2023, GBT 6730.84-2023, GBT6730.84-2023) & related versions
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusSimilar PDF
GB/T 6730.84-2023English260 Add to Cart 0-9 seconds. Auto delivery. Iron ores - Determination of total rare earth content - Inductively coupled plasma atomic emission spectrometric method GB/T 6730.84-2023 Valid GBT 6730.84-2023
Buy with any currencies (Euro, JPY, KRW...): GB/T 6730.84-2023    Preview this PDF: GB/T 6730.84-2023



GB/T 6730.84-2023 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 73.060.10 CCS D 31 Iron ores - Determination of total rare earth content - Inductively coupled plasma atomic emission spectrometric method ISSUED ON: AUGUST 06, 2023 IMPLEMENTED ON: MARCH 01, 2024 Issued by: State Administration for Market Regulation. Standardization Administration of PRC. Table of Contents Foreword ... 3 Introduction ... 4 1 Scope ... 5 2 Normative references ... 5 3 Terms and definitions ... 6 4 Principles ... 6 5 Reagents and materials ... 6 6 Instruments and equipment ... 10 7 Sampling and specimen preparation ... 10 8 Analytical procedures ... 10 9 Result calculation and representation ... 13 10 Test report ... 16 Appendix A (Informative) Released Parts of GB/T 6730 ... 17 Appendix B (Normative) Procedure for acceptance of specimen analysis results ... 22 Appendix C (Informative) Precision test raw data ... 23 Iron ores - Determination of total rare earth content - Inductively coupled plasma atomic emission spectrometric method Warning - Personnel using this document shall have practical experience in regular laboratory work. This document does not identify all possible safety issues. Users are responsible for taking appropriate safety and health measures and ensuring compliance with the conditions, which are stipulated in relevant national regulations. 1 Scope This document describes a method for the determination of total rare earth content, by inductively coupled plasma atomic emission spectrometry. This document is applicable to the determination of the total rare earth content in iron ore, iron concentrate, sinter, pellet mineral products. Determination range (mass fraction): 0.10% ~ 15.00%. 2 Normative references The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, for dated reference documents, only the version corresponding to the date applies to this document; for undated reference documents, the latest version (including all amendments) applies to this document. GB/T 6379.1 Accuracy (trueness and precision) of measurement methods and results - Part 1: General principles and definitions GB/T 6379.2 Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method GB/T 6682 Water for analytical laboratory use - Specification and test methods GB/T 6730.1 Iron ores - Preparation of pre-dried test samples for chemical analysis GB/T 8170 Rules of rounding off for numerical values & expression and judgement of limiting values 5.8 Hydrochloric acid, 5 + 95. 5.9 Nitric acid, ρ≈1.42 g/mL. 5.10 Nitric acid, 1 + 1. 5.11 Hydrogen peroxide, 30%. 5.12 Sodium hydroxide lotion, 20 g/L. Weigh 2 g of sodium hydroxide. Dissolve it in 100 mL of water. 5.13 Triethanolamine, 5 + 95. Measure 5 mL of triethanolamine. Add 95 mL of water. Mix well. 5.14 Yttrium oxide standard storage solution, 1 mg/mL. Weigh 0.1000 g of yttrium oxide [w (Y2O3/REO) ≥ 99.99%, w (REO) ≥ 99.5%] that has been burned at 950 °C for 1 hour. Place it in a 100 mL beaker. Add 10 mL of hydrochloric acid (see 5.7). Heat at low temperature to dissolve it completely. Cool to room temperature. Transfer to a 100 mL volumetric flask. Use water to dilute it to the mark. Mix well. 5.15 Lanthanum oxide standard storage solution, 1 mg/mL. Weigh 0.1000 g of lanthanum oxide [w (La2O3/REO) ≥ 99.99%, w (REO) ≥ 99.5%] that has been burned at 950 °C for 1 hour. Place it in a 100 mL beaker. Add 10 mL of hydrochloric acid (see 5.7). Heat at low temperature to dissolve it completely. Cool to room temperature. Transfer to a 100 mL volumetric flask. Use water to dilute it to the mark. Mix well. 5.16 Cerium oxide standard storage solution, 1 mg/mL. Weigh 0.1000 g of cerium oxide [w (CeO2/REO) ≥ 99.99%, w (REO) ≥ 99.5%] that has been burned at 950 °C for 1 hour. Place it in a 100 mL beaker. Add 10 mL of nitric acid (see 5.10). Heat at low temperature. Dropwise add hydrogen peroxide (see 5.11), until it is completely dissolved. Cool to room temperature. Transfer to a 100 mL volumetric flask. Use water to dilute it to the mark. Mix well. 5.17 Praseodymium oxide standard storage solution, 1 mg/mL. Weigh 0.1000 g of praseodymium oxide [w (Pr6O11/REO) ≥ 99.99%, w (REO) ≥ 99.5%] that has been burned at 950 °C for 1 hour. Place it in a 100 mL beaker. Add 10 mL of hydrochloric acid (see 5.7). Heat at low temperature to dissolve it completely. Cool to room temperature. Transfer to a 100 mL volumetric flask. Use water to dilute it to the mark. Mix well. 5.18 Neodymium oxide standard storage solution, 1 mg/mL. Weigh 0.1000 g of neodymium oxide [w (Nd2O3/REO) ≥ 99.99%, w (REO) ≥ 99.5%] that has been burned at 950 °C for 1 hour. Place it in a 100 mL beaker. Add 10 mL of hydrochloric acid (see 5.7). Heat at low temperature to dissolve it completely. Cool to room temperature. Transfer to a 100 mL volumetric flask. Use water to dilute it to the mark. Mix well. 5.19 Samarium oxide standard storage solution, 1 mg/mL. Weigh 0.1000 g of samarium oxide [w (Sm2O3/REO) ≥ 99.99%, w (REO) ≥ 99.5%] that has been burned at 950 °C for 1 hour. Place it in a 100 mL beaker. Add 10 mL of hydrochloric acid (see 5.7). Heat at low temperature to dissolve it completely. Cool to room temperature. Transfer to a 100 mL volumetric flask. Use water to dilute it to the mark. Mix well. 5.20 Europium oxide standard storage solution, 1 mg/mL. Weigh 0.1000 g of europium oxide [w (Eu2O3/REO) ≥ 99.99%, w (REO) ≥ 99.5%] that has been burned at 950 °C for 1 hour. Place it in a 100 mL beaker. Add 10 mL of hydrochloric acid (see 5.7). Heat at low temperature to dissolve it completely. Cool to room temperature. Transfer to a 100 mL volumetric flask. Use water to dilute it to the mark. Mix well. 5.21 Gadolinium oxide standard storage solution, 1 mg/mL. Weigh 0.1000 g of gadolinium oxide [w (Gd2O3/REO) ≥ 99.99%, w (REO) ≥ 99.5%] that has been burned at 950 °C for 1 hour. Place it in a 100 mL beaker. Add 10 mL of hydrochloric acid (see 5.7). Heat at low temperature to dissolve it completely. Cool to room temperature. Transfer to a 100 mL volumetric flask. Use water to dilute it to the mark. Mix well. 5.22 Terbium oxide standard storage solution, 1 mg/mL. Weigh 0.1000 g of terbium oxide [w (Tb4O7/REO) ≥ 99.99%, w (REO) ≥ 99.5%] that has been burned at 950 °C for 1 hour. Place it in a 100 mL beaker. Add 10 mL of nitric acid (see 5.10). Heat at low temperature to dissolve it completely. Cool to room temperature. Transfer to a 100 mL volumetric flask. Use water to dilute it to the mark. Mix well. 5.23 Dysprosium oxide standard storage solution, 1 mg/mL. Weigh 0.1000 g of dysprosium oxide [w (Dy2O3/REO) ≥ 99.99%, w (REO) ≥ 99.5%] that has been burned at 950 °C for 1 hour. Place it in a 100 mL beaker. Add 10 mL of hydrochloric acid (see 5.7). Heat at low temperature to dissolve it completely. Cool to room temperature. Transfer to a 100 mL volumetric flask. Use water to dilute it to the mark. Mix well. 6 Instruments and equipment Unless otherwise specified, use usual laboratory equipment. Single-marked volumetric flasks, graduated pipettes, single-marked pipettes shall comply with the requirements of GB/T 12806, GB/T 12807, GB/T 12808, respectively. Corundum crucibles, beakers, volumetric flasks, etc., which are used in the test, are soaked in hydrochloric acid solution (see 5.8) for more than 24 hours, rinsed with water, dried, prepared for use. 6.1 Inductively coupled plasma atomic emission spectrometer shall meet the following requirements: a) The resolution is less than 0.008 nm (at 200 nm); b) Comply with the emission spectrometer calibration procedures and technical indicators required in JJG 768. 6.2 Electric hot plate: Temperature control range 50 °C ~350 °C. 6.3 Muffle furnace: Temperature control range 500 °C ~800 °C. 6.4 Analytical balance: Sensitivity 0.1 mg. 6.5 Corundum crucible. 7 Sampling and specimen preparation 7.1 Laboratory specimen Sampling and specimen preparation shall be carried out, in accordance with GB/T 10322.1. Generally, the specimen particle size is less than 100 μm. If the content of combined water or easy oxides in the specimen is high, the particle size shall be less than 160 μm. The requirements for high combined water and easy oxidation content are in accordance with GB/T 6730.1. 7.2 Preparation of pre-dried specimens Thoroughly mix the laboratory specimens. Take samples using the increment specimen reduction method. According to the provisions of GB/T 6730.1, dry the specimen at a temperature of 105 °C ± 2 °C. Cool it to room temperature in a desiccator for later use. 8 Analytical procedures 8.1 Number of measurements According to Appendix B, the same pre-dried specimen shall be measured independently at least twice. Note: "Independent" means that the results of the second and subsequent measurements are not affected by the results of the previous measurements. In this analytical method, this condition means that the same measured object is independently and repeatedly measured, in a short period of time, by the same operator, using the same equipment and the same test method, in the same laboratory, including the use of appropriate recalibration. 8.2 Specimen size Weigh approximately 0.50 g of the pre-dried specimen (see 7.2), accurate to 0.0001 g. The specimen weighing operation shall be carried out as quickly as possible, to prevent the specimen from absorbing moisture again. 8.3 Blank test and verification test 8.3.1 Blank test Carry out a blank test, along with the specimen analysis. All reagents shall be taken from the same reagent bottle. 8.3.2 Verification test Along with the specimen, analyze the standard samples of the same type, for verification tests. 8.4 Determination 8.4.1 Decomposition of specimens Place the specimen (see 8.2) in a corundum crucible, which contains 3 g ~ 4 g of sodium hydroxide (see 5.1) that has been pre-baked, to remove moisture. Mix evenly. Add 4 g of sodium peroxide (see 5.2) to cover it. Place it in a muffle furnace (See 6.3). Gradually increase the temperature from low temperature to 750 °C and melt, until red and transparent for 5 min ~ 10 min. Shake twice in this process. Take out and cool. 8.4.2 Preparation of analytical solution 8.4.2.1 Move the cooled corundum crucible into a 400 mL beaker, which contains 100 mL of triethanolamine (see 5.13), 1 g of EDTA (see 5.3), 1 g of ascorbic acid (see 5.4), 1 g of hydroxylamine hydrochloride (see 5.5). Wait until the violent reaction stops. heat to boiling. Remove and rinse the crucible. Boil the solution for several minutes. Cool it slightly. Use quantitative medium-speed filter paper to filter it. Use sodium hydroxide washing solution (see 5.12), to rinse the beaker and sediment 6 ~ 7 times. Use 5 mL of hydrochloric acid (see 5.7), to dissolve the precipitate on the filter paper. Filter it into the volumetric flask. After the precipitate is dissolved, use dilute hydrochloric acid (see ......

BASIC DATA
Standard ID GB/T 6730.84-2023 (GB/T6730.84-2023)
Description (Translated English) Iron ores - Determination of total rare earth content - Inductively coupled plasma atomic emission spectrometric method
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard D31
Classification of International Standard 73.060.10
Word Count Estimation 18,188
Date of Issue 2023-08-06
Date of Implementation 2024-03-01
Drafting Organization Baotou Rare Earth Research Institute, Baotou Customs Comprehensive Technical Service Center, Jiangsu Shagang Iron and Steel Research Institute Co., Ltd., Linyi Inspection and Certification Co., Ltd., Metallurgical Industry Information Standards Research Institute, Tianjin Baotou Rare Earth Research Institute Co., Ltd., China Northern Rare Earth (Group) High-tech Co., Ltd., Baotou Group Mining Research Institute (Limited Liability Company), Baotou Rare Earth New Material Technology R&D Center, National Tungsten and Rare Earth Product Quality Supervision and Inspection Center
Administrative Organization National Iron Ore and Direct Reduced Iron Standardization Technical Committee (SAC/TC 317)
Proposing organization China Iron and Steel Industry Association
Issuing agency(ies) State Administration for Market Regulation, National Standardization Administration