HOME   Cart(9)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 23113-2023 English PDF

US$369.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 23113-2023: Sample preparation for measurement of mercury level in discharge lamp
Status: Valid

GB/T 23113: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 23113-2023English369 Add to Cart 4 days [Need to translate] Sample preparation for measurement of mercury level in discharge lamp Valid GB/T 23113-2023
GB/T 23113-2017English639 Add to Cart 4 days [Need to translate] Sample preparation for measurement of mercury level in fluorescent lamps Obsolete GB/T 23113-2017
GB/T 23113-2008English559 Add to Cart 3 days [Need to translate] Measurement of mercury level in fluorescent lamps Obsolete GB/T 23113-2008

PDF similar to GB/T 23113-2023


Standard similar to GB/T 23113-2023

GB/T 43017   GB/T 19258.1   GB 19258   GB/T 17263   GB/T 23112   

Basic data

Standard ID GB/T 23113-2023 (GB/T23113-2023)
Description (Translated English) Sample preparation for measurement of mercury level in discharge lamp
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K71
Classification of International Standard 29.140.30
Word Count Estimation 18,163
Date of Issue 2023-11-27
Date of Implementation 2024-06-01
Older Standard (superseded by this standard) GB/T 23113-2017
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 23113-2023: Sample preparation for measurement of mercury level in discharge lamp

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 29:140:30 CCSK71 National Standards of People's Republic of China Replace GB/T 23113-2017 Sample preparation for mercury content detection in discharge lamps Published on 2023-11-27 2024-06-01 Implementation State Administration for Market Regulation Released by the National Standardization Administration Committee

Table of contents

Preface III 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Overview 1 5 Procedure for collecting mercury from discharge lamps 2 5:1 General requirements 2 5:2 Reagents 2 5:3 Chemical experiment equipment 2 5:4 Sample preparation 2 5:5 Sample digestion 6 5:6 Filtering 7 6 test 7 6:1 Blank test 7 6:2 Data reporting 7 6:3 Analytical testing 7 Appendix A (Informative) Information related to the cold end method 8 Appendix B (Informative) Electrothermal Vaporization Atomic Absorption Spectrometry (EVAAS) 11

Foreword

This document complies with the provisions of GB/T 1:1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents" Drafting: This document replaces GB/T 23113-2017 "Sample Preparation for Detection of Mercury Content in Fluorescent Lamps": Compared with GB/T 23113-2017, except In addition to structural adjustments and editorial changes, the main technical changes are as follows: ---Changed the scope of the file (see Chapter 1, Chapter 1 of the:2017 edition); ---Added a chapter of "Terms and Definitions" (see Chapter 3); ---"Fluorescent lamp" in the document is changed to "discharge lamp" (see Chapter 1, Chapter 4, Chapter 5, Chapter 1, Chapter 3, Chapter:2017 version Chapter 4); ---Changed the general requirements for laboratories (see 5:1, 4:1 of the:2017 version); ---Deleted some unused chemical experimental equipment (see 4:3 of the:2017 version); ---Changed the lighting method of the cold end method (see 5:4:1:1, 4:4:1:1 of the:2017 version); ---Changed the interception method of the lamp [see 5:4:4e), 5:4:4g),:2017 version 4:4:4e), 4:4:4g)]; ---Deleted redundant operations [see:2017 version 4:4:1:2h), 4:4:4]; ---Changed the filtering requirements (see 5:6, 4:6 of the:2017 version); ---Changed the requirements for analytical testing (see 6:3, 5:3 of the:2017 version): This document is modified to adopt IEC 62554:2017 "Sample Preparation for Detection of Mercury Content in Fluorescent Lamps": Compared with IEC 62554:2017, this document has made the following structural adjustments: ---Appendix A corresponds to Appendix B in IEC 62554:2017, and Appendix B corresponds to Appendix A in IEC 62554:2017: The technical differences between this document and IEC 62554:2017 and their reasons are as follows: ---The scope of the document has been changed (see Chapter 1, Chapter 1 of IEC 62554:2017) to adapt to the actual needs of my country's products; ---Deleted terms and their definitions (see Chapter 3 of IEC 62554:2017), and added terms referencing GB/T 2900:65 (see Chapter 3), to adapt to my country’s technical conditions; ---Changed the general requirements for laboratories and replaced ISO /IEC 17025:2005 with GB/T 27025 (see 5:1, IEC 62554: 5:1) of:2017, to adapt to my country’s technical conditions; ---Changed the water requirements and replaced ISO 3696:1987 with GB/T 6682 (see 5:2, 5:2 of IEC 62554:2017) to suit In response to my country’s technical conditions; ---Deleted some unused chemical experimental equipment (see 5:3 of IEC 62554:2017) to conform to actual operation; ---The lighting method of the cold end method has been changed (see 5:4:1:1, 5:4:1:1 of IEC 62554:2017) to adapt to some pipe walls during ignition Very hot discharge lamps; ---Changed the interception method of the lamp [see 5:4:4e), 5:4:4g), IEC 62554:2017 5:4:4e), 5:4:4g)] to provide more Light tube interception method; ---The usage concentration of nitric acid has been changed [see 5:5:2a), 5:5:2a) of IEC 62554:2017] to ensure safe use; ---Changed the requirements for analytical testing, replacing IEC 62321-4 with GB/T 39560:4 (see 6:3, IEC 62554:2017 6:3), to adapt to my country’s technical conditions: The following editorial changes have been made to this document: ---In order to coordinate with the existing standards, the name of the standard is changed to "Sample Preparation for Detection of Mercury Content in Discharge Lamps"; ---Change the permissive clauses in some notes to declarative clauses; ---Changed the upper limit of the cold end method temperature in Note 5:4:1:1; ---Changed the test method in Appendix A: Please note that some content in this document may be subject to patents: The publisher of this document assumes no responsibility for identifying patents: This document is proposed by China Light Industry Federation: This document is under the jurisdiction of the National Lighting Appliances Standardization Technical Committee (SAC/TC224): This document was drafted by: Zhongshan Quality Supervision and Inspection Institute of Guangdong Province, Shenzhen Lighting and Display Engineering Industry Association, Beijing Electro-optical SOURCE INSTITUTE LIMITED: The main drafters of this document: Peng Zhenjian, Jing Fajun, Zhang Bo, Wu Qiong, Fu Zhimin, Wu Xiaosen, Qiao Zhenzhong: The previous versions of this document and the documents it replaces are as follows: ---First published as GB/T 23113-2008 in:2008, first revised in:2017; ---This is the second revision: Sample preparation for mercury content detection in discharge lamps

1 Scope

This document specifies procedures for sample preparation and testing for the determination of mercury content in discharge lamps: This document is applicable to the detection of mercury content (not less than 0:1 mg) in discharge lamps (including fluorescent lamps and ultraviolet lamps): Other mercury-containing discharge lamps Refer to use: This document does not contain all measurement information: Detailed measurement information is described in GB/T 39560:4:

2 Normative reference documents

The contents of the following documents constitute essential provisions of this document through normative references in the text: Among them, the dated quotations For undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to this document: GB/T 2900:65 Electrical terminology lighting (GB/T 2900:65-2023, IEC 60050-845:2020, IDT) GB/T 6682 Analytical laboratory water specifications and test methods (GB/T 6682-2008, ISO 3696:1987, MOD) GB/T 27025 General requirements for testing and calibration laboratory capabilities (GB/T 27025-2019, ISO /IEC 17025:2017, IDT) GB/T 39560:4 Determination of certain substances in electronic and electrical products Part 4: CV-AAS, CV-AFS, ICP-OES and Determination of mercury in polymers, metals and electronic parts by ICP-MS (GB/T 39560:4-2021, IEC 62321-4:2013, IDT)

3 Terms and definitions

The terms and definitions defined in GB/T 2900:65 apply to this document:

4 Overview

Mercury in discharge lamps covered by this document is present in the following states: a) Gaseous state in the lamp; b) liquid metal; c) compounds; d) Alloys: Due to the differences in the shape, location, composition and structure of mercury-containing devices, there are various quantitative mercury injection schemes: Although some lamps contain amalgam Mercury is injected in the form of solid amalgam or solid amalgam, but there are also many lamps in which liquid mercury is injected: Mercury amalgam lamps often have devices that serve as auxiliary amalgams, and the shapes and placement of these devices are very diverse: See Appendix A for instructions on how to use the cold end method to minimize the loss of vapor mercury when opening the pipe: When the lamp is in working condition, all the mercury in the lamp tube will be rich in Concentrated at the cold end, this will help control mercury recovery: The procedures in Chapter 5 include methods for collecting liquid mercury, combined mercury, amalgams, and amalgams: Liquid mercury, combined mercury, amalgam and amalgam are tested to obtain the total mercury content:

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 23113-2023_English be delivered?

Answer: Upon your order, we will start to translate GB/T 23113-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 23113-2023_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 23113-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 23113-2023?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 23113-2023 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.