HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (12 Oct 2025)

GB/T 18853-2015 English PDF

US$739.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 18853-2015: Hydraulic fluid power filters -- Multi-pass method for evaluating filtration performance of a filter element
Status: Valid

GB/T 18853: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 18853-2015English739 Add to Cart 5 days [Need to translate] Hydraulic fluid power filters -- Multi-pass method for evaluating filtration performance of a filter element Valid GB/T 18853-2015
GB/T 18853-2002EnglishRFQ ASK 6 days [Need to translate] Hydraulic fluid power filters -- Multi-pass method for evaluating filtration performance of a filter element Obsolete GB/T 18853-2002

PDF similar to GB/T 18853-2015


Standard similar to GB/T 18853-2015

GB/T 20080   GB/T 17491   GB/T 20079   GB/T 22107   GB/T 18854   

Basic data

Standard ID GB/T 18853-2015 (GB/T18853-2015)
Description (Translated English) Hydraulic fluid power filters -- Multi-pass method for evaluating filtration performance of a filter element
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard J20
Classification of International Standard 25.220.10
Word Count Estimation 35,321
Date of Issue 2015-12-31
Date of Implementation 2016-07-01
Older Standard (superseded by this standard) GB/T 18853-2002
Quoted Standard GB/T 786.1; GB/T 14041.1; GB/T 17446; GB/T 17484; GB/T 17486; GB/T 17489; GB/T 18854; GB/T 21540; GB/T 27613; GB/T 28957.1-2012
Adopted Standard ISO 16889-2008, MOD
Regulation (derived from) State Standard Announcement 2015 No.43
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the following: a) multiple pass filtration performance tests for hydraulic transmission elements under contaminant continuous injection conditions; b) procedures for the determination of scale capacity, particle filtration and differential pressure characteristics; c) presently applicable to hydraulic pressure Transmission filter test. The filter has an average filtration ratio greater than or equal to 75 for particles less than or equal to 25 ��m in size (c) and less than 200 mg/L for the tank weight at the end of the test; d) the use of ISO Intermediate Test Powder and Annex A Test oil. The test conditions are: 1, the upstream basic weight pollution degree is 3mg/L; the test condition 2, the upstream basic weight pollution degree is 10mg/L; the test condition 3, the upstream basic weight pollution degree is 15mg/Lt; /RTI & gt;

GB/T 18853-2015: Hydraulic fluid power filters -- Multi-pass method for evaluating filtration performance of a filter element


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Hydraulic fluid power filters.Multi-pass method for filtration skin performance of a filter element ICS 23.100.60 J20 National Standards of People's Republic of China Replace GB/T 18853-2002 Hydraulic drive filter A method of evaluating the filter performance of filter elements (ISO 16889..2008, MOD) 2015-12-31 released 2016-07-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China China National Standardization Management Committee released Directory Preface I Introduction III 1 Scope 1 2 normative reference document 1 3 Terms and definitions 2 4 symbol 3 5 General procedure 4 6 test equipment 4 7 Test instrument accuracy and test conditions of the range of 5 8 Filter performance test circuit verification procedures 6 9 Required information before trial 8 10 Preparation before trial 8 11 Filter Performance Test 10 12 Calculate 11 13 data expression 12 14 Note 13 Appendix A (normative) Basic performance of test oil 16 Appendix B (informative) Guidelines for the design of test systems 18 Appendix C (Informative Appendix) Calculation and Chart Report Example 22 Reference 29

Foreword

This standard is drafted in accordance with the rules given in GB/T 1.1-2009. This standard instead of GB/T 18853-2002 "hydraulic transmission filter to assess the filter filter performance of multiple pass method", and GB/T 18853-2002 compared to the main technical changes are as follows. --- modified version of the normative reference documents ISO 11943 and ISO 4405, using the latest version (see Chapter 2,.2002 Yearbook Chapter 2). The normative reference document, ASTM D4308, was deleted and included in the references (see Chapter 2 of.2002). --- modified part of the parameter symbols (see 4.2,.2002 version 4.2). - increase the particle size (x1, x2) and the particle size (xint) calculated using the interpolation method (see Table 1). - increased drying requirements and standardized requirements for test powder over.200 g (see 6.3). - Increased use of antistatic additives (see 10.3.2). - Increased number of digital processing requirements for the calculation of the average number of particles (see 12.5d)). --- modified the expression of the average number of the average number of particles in the upper and lower reaches (see 12.7,.2002 edition 12.7). - Removes the number of weight contaminants for upstream oil samples (see 12.10). This standard uses the re-drafting method to modify the use of ISO 16889..2008 "hydraulic drive filter filter filter performance evaluation of multiple pass Method "(English version). The technical differences between this standard and ISO 16889..2008 are as follows. - to modify the normative reference documents to meet the technical conditions of our country, the adjustment of the situation is reflected in Chapter 2 "normative reference File ", the specific adjustments are as follows. • Replace ISO 1219-1 (see 4.1) with GB/T 786.1 equivalent to the international standard; • Replace ISO 2942 with equivalent GB/T 14041.1 with international standards (see Chapter 9); • GB 5598 (see Chapter 3) with GB/T 17446 equivalent to international standards; • Replace ISO 3722 (see 6.5) with GB/T 17484 equivalent to international standards; • ISO 3968 (see 6.7.1) is replaced by GB/T 17486 equivalent to the international standard; • ISO 4021 (see 6.7.1) is replaced by GB/T 17489 equivalent to the international standard; • GB 11171 (see 4.2) is replaced by GB/T 18854 with an international standard; • ISO 11943 (see 6.4) with GB/T 21540 equivalent to international standards; • ISO 4405 is replaced by GB/T 27613 with an international standard (see 6.8); • Replace ISO 12103-1 (see 6.3) with GB/T 28957.1 with international standard modifications; - Removes ISO 17889..2008 normative reference file ISO 5725, since this file is only available in the "Appendix D" section Quotes. --- increase the test in the 9th test before the test oil viscosity 14mm2/s and 16mm2/s corresponding to the temperature requirements to improve the test The accuracy of the results. --- Added A.5 in the domestic oil YH-10, YH-12 and YH-15 as qualified oil to meet the test oil in China Application. --- Added footnote to the special function fuel tank symbol in the system schematic of Appendix B, which is marked in GB/T 786.1 Is not specified, so the use of ISO 16889 in the expression. --- modify the Appendix B of the system schematic diagram of the temperature regulator of the expression symbols, using GB/T 786.1 in the expression of the provisions. This standard has made the following editorial changes. - Removed the ISO 16889..2008 information Appendix D, modified the "reference". Because these two aspects of the standard so that the With the relationship is not, and increased the length of the standard. This standard is proposed by the China Machinery Industry Federation. This standard by the National Hydraulic and Pneumatic Standardization Technical Committee (SAC/TC3) centralized. This standard is responsible for the drafting unit. National Defense Science and Technology Industrial Granularity Level 1 metering station. This standard participates in the drafting unit. Jiujiang Seven Precision Electromechanical Technology Co., Ltd., Beijing University of Chemical Technology, Xinxiang Pingfei Filter Co., Ltd. Division, Liming Hydraulic Co., Ltd. The main drafters of this standard. Du Lifeng, Liu Yong, Lu Hongnan, Li Fangjun, Lu sent Zhong, Ye Ping, Zhang Wan. This standard replaced the previous version of the standard release. --- GB/T 18853-2002.

Introduction

In the hydraulic system, the solid particulate contaminants by increasing wear, stuck, siltation, clogging and accelerating oil oxidation deterioration, etc. And the annex, resulting in reduced reliability, improved failure rate, shorten the life of accessories and other issues. The hydraulic filter is used to control the circulation in the hydraulic system Of the number of polluted particles, so that the pollution level of oil to meet the hydraulic accessories of the pollution tolerance and the user needs the reliability requirements. in order to It is advisable to compare the performance of the filter to select the most suitable filter. The performance characteristics of the filter depend on the filter element (Its filter and geometry) and the filter housing (its structural shape and seal design). In fact, the hydraulic oil carries contaminants continuously Flows through the filter until the filter flow resistance reaches the pre-set ultimate differential pressure (bypass valve opening pressure or pressure difference set by the differential pressure indicator). The filter service life (before reaching the limit pressure difference) and the pollution rate at any point in the hydraulic system are related to the rate of increase in pollutants (invasion rate and generation Rate and the performance of the filter are closely related. Therefore, in the laboratory for the performance evaluation of the filter should be tested for the filter The device provides a continuous amount of contaminant, and regularly monitors the filtration performance parameters of the filter. The test should have a degree of reproducibility and reproducibility. The standard test contaminants are the ISO intermediate test specified in ISO 12103-1 Test powder (ISO MTD, ISO 12103-A3). This test powder has a stable uniform particle size distribution and is available all over the world Can be purchased. The upstream and downstream particle size distribution of the filter should be measured using an automatic particle counter calibrated according to GB/T 18854. The results of the filter to determine the filter performance. It is difficult to specify the circulation flow that is consistent with the flow variation in the actual hydraulic system And therefore, in this test method using steady-state conditions as a test case, in order to improve the reproducibility of the test results and reproducibility. Hydraulic drive filter A method of evaluating the filter performance of filter elements

1 Scope

This standard specifies the following. a) hydraulic transmission filter in the continuous injection of pollutants under the conditions of multiple filtration performance test; b) procedures for determining the scale capacity, particle filtration and differential pressure characteristics; c) Tests currently applicable to hydraulic drive cartridges. This filter has an average particle size of particles smaller than or equal to 25 μm (c) Ratio greater than or equal to 75, and the end of the test tank weight pollution degree of less than.200mg/L; Note. The flow range of the test equipment and the lower limit of the particle size are determined by validation. d) Tests using ISO intermediate test powder and test oil specified in Annex A. This standard applies to the following three test conditions. --- test conditions 1, the upstream basic weight pollution degree of 3mg/L; --- test conditions 2, the upstream basic weight pollution rate of 10mg/L; --- test conditions 3, the upstream basic weight pollution degree of 15mg/L.

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. GB/T 786.1 Fluid drive systems and components - Graphical symbols and circuit diagrams - Part 1. Diagrams for general use and data processing (GB/T 786.1-2009, ISO 1219-1..2006, IDT) GB/T 14041.1 Hydraulic filter elements - Part 1. Verification of structural integrity and determination of initial bubble point (GB/T 14041.1- 2007, ISO 2942..2004, IDT) GB/T 17446 fluid transmission system and component vocabulary (GB/T 17446-2012, ISO 5598..2008, IDT) GB/T 17484 Identification and control of hydraulic oil sampling containers for purification methods (GB/T 17484-1998, idtISO 3722. 1976) GB/T 17486 Evaluation of pressure flow characteristics of hydraulic filters (GB/T 17486-2006, ISO 3968..2001, IDT) GB/T 17489 Hydraulic particle contamination analysis Extraction of liquid samples from working system piping (GB/T 17489-1998, idt ISO 4021..1992) GB/T 18854 Calibration of hydraulic drive liquid automatic particle counters (GB/T 18854-2015, ISO 11171..2010, MOD) GB/T 21540 hydraulic transmission liquid on-line automatic particle counting system calibration and verification methods (GB/T 21540-2008, ISO 11943..1999, IDT) GB/T 27613 Hydraulic transmission - Liquid contamination - Determination of particle contamination by weighing method (GB/T 27613-2011, ISO 4405..1991, MOD) GB/T 28957.1-2012 Road vehicles - Test dust for filter evaluation - Part 1. Silica test dust (ISO 12103-1..1997, MOD)