US$794.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 16895.23-2020: Low-voltage electrical installations - Part 6: Verification Status: Valid GB/T 16895.23: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 16895.23-2020 | English | 794 |
Add to Cart
|
5 days [Need to translate]
|
Low-voltage electrical installations - Part 6: Verification
| Valid |
GB/T 16895.23-2020
|
| GB/T 16895.23-2012 | English | RFQ |
ASK
|
3 days [Need to translate]
|
Low-voltage electrical installations -- Part 6: Verification
| Obsolete |
GB/T 16895.23-2012
|
| GB/T 16895.23-2005 | English | 759 |
Add to Cart
|
3 days [Need to translate]
|
The building electrical 6-16: Verification -- Initial verification
| Obsolete |
GB/T 16895.23-2005
|
PDF similar to GB/T 16895.23-2020
Basic data | Standard ID | GB/T 16895.23-2020 (GB/T16895.23-2020) | | Description (Translated English) | Low-voltage electrical installations - Part 6: Verification | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | Q77 | | Classification of International Standard | 91.140.50 | | Word Count Estimation | 42,496 | | Date of Issue | 2020-12-14 | | Date of Implementation | 2021-07-01 | | Older Standard (superseded by this standard) | GB/T 16895.23-2012 | | Regulation (derived from) | National Standard Announcement No. 28 of 2020 | | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 16895.23-2020: Low-voltage electrical installations - Part 6: Verification---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Low-voltage electrical installations Part 6: Inspection)
ICS 91:140:50
Q77
National Standards of People's Republic of China
Replace GB/T 16895:23-2012
Low-voltage electrical installations Part 6: Inspection
(IEC 60364-6:2016, IDT)
2020-12-14 release
2021-07-01 implementation
State Administration for Market Regulation
Issued by the National Standardization Management Committee
Table of contents
Preface Ⅲ
6:1 Scope 1
6:2 Normative references 1
6:3 Terms and definitions 2
6:4 Initial inspection 2
6:4:1 General 2
6:4:2 Inspection 3
6:4:3 Test 3
6:4:4 Initial inspection report 8
6:5 Periodic inspection 8
6:5:1 General 8
6:5:2 Periodic inspection interval 9
6:5:3 Periodic inspection report 9
Appendix A
(Informative appendix) Resistance estimate that may be obtained during the continuity test 10
Appendix B
(Informative appendix) Method of measuring insulation resistance/impedance of floor and wall to ground or protective conductor 11
B:1 General 11
B:2 Method of measuring the impedance of floors and walls using AC voltage 11
B:3 Test electrode 1 11
B:4 Test electrode 2 12
Appendix C
(Informative appendix) Measurement of ground electrode resistance---Method C1, Method C2 and Method C3 13
C:1 Method C1---Earth electrode resistance measurement using earth electrode test equipment 13
C:2 Method C2---Use a fault loop impedance tester to measure ground electrode resistance 14
C:3 Method C3---Using a current clamp to measure ground electrode resistance 15
Appendix D
(Informative appendix) 6:4 Application guidelines for initial inspection 17
Appendix E
(Informative appendix) Report template 19
Appendix F
(Informative appendix) Electrical installation inspection template 26
F:1 List of check items for initial inspection of electrical installations 26
F:2 List of inspection items for existing electrical installations 29
Appendix G
(Informative appendix) Circuit details and test result list template 34
Reference 35
Figure B:1 Test electrode 1 12
Figure B:2 Test electrode 2 12
Figure C:1 Measuring ground electrode resistance 13
Figure C:2 Use the fault loop impedance test equipment to measure the ground electrode resistance 15
60364-6:2016
Figure C:3 Use current clamp to measure ground electrode resistance 16
Table 6:1 Minimum insulation resistance 4
Table A:1 According to the nominal cross-sectional area S to 30
The specific resistance value R of copper conductor at ℃ can be used to estimate conductor resistance 10
Table E:1 Electrical installation inspection report (new or modified installation) 19
Table E:2 Status report of electrical installations (existing installations) 21
Table G:1 Circuit details and test result list template 34
60364-6:2016
Foreword
GB/T
16895 "Low-Voltage Electrical Installations" is divided into 5 parts, and each part is divided into multiple sub-parts:
---Part 1: Evaluation and definition of basic principles, general characteristics;
---Part 4: Security Protection;
---Part 5: Selection and installation of electrical equipment;
---Part 6: Inspection;
---Part 7: Requirements for special devices or places:
This part is GB/T
Part 6 of 16895:
This part is in accordance with GB/T
Drafting of the rules given in 1:1-2009:
This part replaces GB/T
16895:23-2012
"Low-Voltage Electrical Installation Part 6: Inspection", and GB/T
16895:23-2012
In comparison, the main technical changes are as follows:
---Modified normative reference documents (see 6:2,:2012 edition 6:2);
---Added 3 items of preliminary inspection regulations (see 6:4:2:3);
---Modified the test sequence (see 6:4:3:1, 61:3:1 of the:2012 edition);
---Added more details in the general provisions of periodic inspection (see 6:5:1);
--- Added Table A:1 (see Appendix A) for the specific resistance value of copper conductors;
--- Deleted the example of the simplified diagram of the original Appendix D on the voltage drop evaluation (see Appendix D of the:2012 edition);
--- Deleted the original Appendix E recommendations for electrical equipment that have been reused in electrical installations (see Appendix E of the:2012 edition):
The translation method used in this part is equivalent to the IEC
60364-6:2016 "Low-Voltage Electrical Installation Part 6: Inspection":
The Chinese documents that have a consistent correspondence with the international documents cited in this section are as follows:
---GB
3836:16-2017 Electrical equipment for explosive gas atmosphere Part 16: Inspection and maintenance of electrical installations (coal mine
Except) (IEC
60079-17:2007,
IDT);
---GB/T
16895 (all parts) Low-voltage electrical installations [IEC
60364 (all parts), IDT);
---GB/T
16895:3-2017 Low-voltage electrical installations Part 5-54: Selection and installation of electrical equipment
Grounding configuration and protection
Protective conductor (IEC
60364-5-54:2011, IDT);
---GB/T
18216 (all parts) Exchange 1
000
V and DC 1
500
Electrical safety protection measures for low-voltage power distribution systems below V
Testing, measuring or monitoring equipment [IEC
61557 (all parts), IDT);
This section has made the following editorial changes:
---Corrected IEC
60364-6:2016/COR1:2017 content;
---IEC
In 60364-6:2016 6:5:1:2, g) and c) are repeated, h) and d) are repeated, and g) and h) are deleted in this section;
---IEC
60364-6: The 61:4:2 cited in Appendix E of:2016, amended 6:4 according to the content of the main text; 62:1 cited in Table E:2:
4 and 62:1:5 are merged into 6:5;
---IEC
Appendix H of 60364-6:2016 is a note applied in other countries, which has nothing to do with my country, and is deleted in this section;
---IEC has been deleted
60364-6:2016 Note 6:4:1:6, 6:5:1:5 Note and 6:5:3:6 Note 2:
This part is organized by the National Standardization Technical Committee for Building Electrical Installations (SAC/TC
205) Propose and manage:
Drafting organizations of this section: CMC China Design & Research Institute Co:, Ltd:, Unitech (China) Co:, Ltd:, Suzhou Electrical Appliance Science
Research Institute Co:, Ltd:, Beijing Xingdian International Engineering Management Co:, Ltd:, Xiamen Jiatli Technology Co:, Ltd:, Legrand low-voltage electrical appliances (no
60364-6:2016
Tin) Co:, Ltd:, Siemens (China) Co:, Ltd:, Schneider Electric (China) Co:, Ltd:
The main drafters of this section: Ren Changning, Huang Baosheng, Hong Shaojun, Hong Shaolin, Mao Xiang, Hu Delin, Hu Jianping, Liu Yang, Hu Hongyu, Tang Ying,
Zheng Haifeng:
The previous versions of the standards replaced by this part are as follows:
---GB/T
16895:23-2005; GB/T
16895:23-2012:
60364-6:2016
Low-voltage electrical installations Part 6: Inspection
6:1 Scope
GB/T
This part of 16895 gives the initial inspection and periodic inspection requirements for electrical installations:
Through inspection and testing, Chapter 6:4 gives the requirements for the initial inspection of electrical installations, as far as possible to determine GB/T
16895
Whether the relevant requirements of other parts of the company have been met, and put forward the requirements for the initial inspection result report: Upon completion of new installations or existing installations
After the restructuring and expansion are completed, the initial inspection will be carried out:
Chapter 6:5 gives periodic inspections of electrical installations to ascertain as far as possible whether the installation and all its supporting equipment meet the requirements for use:
And the requirements for periodic inspection results reporting:
6:2 Normative references
The following documents are indispensable for the application of this document: For dated reference documents, only the dated version applies to this article
Pieces: For undated references, the latest version (including all amendments) applies to this document:
GB/T
16895:2-2017 Low-voltage electrical installations Part 4-42: Safety protection Thermal effect protection (IEC
60364-4-42:
2010, IDT)
GB/T
16895:6-2014 Low-voltage electrical installations Part 5-52: Selection of electrical equipment and installation wiring system (IEC
60364-5-52:2009, IDT)
GB/T
16895:10-2010
Low-voltage electrical installations Part 4-44: Safety protection Voltage disturbance and electromagnetic disturbance protection (IEC
60364-4-44:2007,IDT)
GB/T
16895:18-2010 Electrical installations of buildings Part 5-51: General rules for the selection and installation of electrical equipment (IEC
60364-5-51:2005, IDT)
GB/T
16895:21-2011 Low-voltage electrical installations Part 4-41: Safety protection Electric shock protection (IEC
60364-4-41:
2005, IDT)
GB/T
16895:22-2004 Building Electrical Installations Part 5-53: Selection and Installation of Electrical Equipment-Isolation, Switching and Control
Section 534: Overvoltage Protection Equipment (IEC
60364-5-53:2001/AMD1:2002, IDT)
IEC
60079-17 Explosive atmosphere Part 17: Inspection and maintenance of electrical installations (Explosive
atmospheres-Part
17:
Electrical
instalations
inspection
and
maintenance)
IEC
60364 (all parts) Low-voltage electrical equipment (Low-voltage
electrical
instalations)
IEC
60364-4-42:2010/
AMD1:2014 Low-Voltage Electrical Installation Part 4-42: Safety Protection Thermal Effect Protection (Low-
voltage
electrical
instalations-Part
4-42:
Protection
for
safety-Protection
against
thermal
effects)
IEC
60364-4-44:2007/AMD1:2015 Low-voltage electrical installations Part 4-44: Safety protection against voltage disturbances and electromagnetic disturbances
Interference protection (Low-voltage
electrical
instalations-Part
4-44:
Protection
for
safety-Protection
against
volt-
age
disturbances
and
electromagnetic
disturbances)
IEC
60364-5-53:2001/AMD2:2015 Electrical installations of buildings Part 5-53: Selection and installation of electrical equipment
Section 534: Switchgear and Control Equipment (Electrical
instalations
of
buildings-Part
5-53:
Selection
and
erection
of
electrical
equipment-Isolation,
switching
and
control-Section
534: Devices
for
protection
against
ov-
ervoltages)
IEC
60364-5-54 Low-voltage electrical installations Part 5-54: Selection and installation of electrical equipment, grounding arrangements and protective conductors
60364-6:2016
|